Virtual arterial blood pressure feedback improves chest compression quality during simulated resuscitation

被引:8
作者
Rieke, Horst [1 ]
Rieke, Martin [2 ]
Gado, Samkon K. [1 ]
Nietert, Paul J. [3 ]
Field, Larry C. [1 ]
Clark, Carlee A. [1 ]
Furse, Cory M. [1 ]
McEvoy, Matthew D. [4 ]
机构
[1] Med Univ S Carolina, Dept Anesthesia & Perioperat Med, Charleston, SC 29425 USA
[2] Ruhr Univ Bochum, Inst Theoret Phys 1, D-44801 Bochum, Germany
[3] Med Univ S Carolina, Div Biostat & Epidemiol, Dept Med, Charleston, SC 29425 USA
[4] Vanderbilt Univ, Dept Anesthesiol, Nashville, TN 37232 USA
关键词
Cardiopulmonary resuscitation; Chest compressions; Simulation; Arterial blood pressure; CARDIOPULMONARY-RESUSCITATION; CARDIAC-ARREST; CPR;
D O I
10.1016/j.resuscitation.2013.06.014
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Quality chest compressions (CC) are the most important factor in successful cardiopulmonary resuscitation. Adjustment of CC based upon an invasive arterial blood pressure (ABP) display would be theoretically beneficial. Additionally, having one compressor present for longer than a 2-min cycle with an ABP display may allow for a learning process to further maximize CC. Accordingly, we tested the hypothesis that CC can be improved with a real-time display of invasively measured blood pressure and with an unchanged, physically fit compressor. Methods: A manikin was attached to an ABP display derived from a hemodynamic model responding to parameters of CC rate, depth, and compression-decompression ratio. The area under the blood pressure curve over time (AUC) was used for data analysis. Each participant (N = 20) performed 4 CPR sessions: (1) No ABP display, exchange of compressor every 2 min; (2) ABP display, exchange of compressor every 2 min; (3) no ABP display, no exchange of the compressor; (4) ABP display, no exchange of the compressor. Data were analyzed by ANOVA. Significance was set at a p-value < 0.05. Results: The average AUC for cycles without ABP display was 5201 mmHg s (95% confidence interval (CI) of 4804-5597 mmHg s), and for cycles with ABP display 6110 mmHg s (95% CI of 5715-6507 mmHg s) (p < 0.0001). The average AUC increase with ABP display for each participant was 20.2 +/- 17.4% 95 CI (p < 0.0001). Conclusions: Our study confirms the hypothesis that a real-time display of simulated ABP during CPR that responds to participant performance improves achieved and sustained ABP. However, without any real-time visual feedback, even fit compressors demonstrated degradation of CC quality. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1585 / 1590
页数:6
相关论文
共 50 条
  • [41] QUALITY COMPARISON OF THE MANUAL CHEST COMPRESSION AND THE MECHANICAL CHEST COMPRESSION DURING DIFFICULT TRANSPORT CONDITIONS
    Bekgoz, Burak
    San, Ishak
    Ergin, Mehmet
    JOURNAL OF EMERGENCY MEDICINE, 2020, 58 (03) : 432 - 438
  • [42] Defibrillation delivered during the upstroke phase of manual chest compression improves shock success
    Li, Yongqin
    Wang, Hao
    Cho, Jun Hwi
    Quan, Weilun
    Freeman, Gary
    Bisera, Joe
    Weil, Max Harry
    Tang, Wanchun
    CRITICAL CARE MEDICINE, 2010, 38 (03) : 910 - 915
  • [43] Suction cup on a piston-based chest compression device improves coronary perfusion pressure and cerebral oxygenation during experimental cardiopulmonary resuscitation
    Malberg, Johan
    Smekal, David
    Marchesi, Silvia
    Lipcsey, Miklos
    Rubertsson, Sten
    RESUSCITATION PLUS, 2022, 12
  • [44] Immediate and 1-Year Chest Compression Quality Effect of Instantaneous Feedback in Simulated Cardiac Arrest
    Griffin, Peter
    Cooper, Clayton
    Glick, Joshua
    Terndrup, Thomas E.
    SIMULATION IN HEALTHCARE-JOURNAL OF THE SOCIETY FOR SIMULATION IN HEALTHCARE, 2014, 9 (04): : 264 - 269
  • [45] Randomised study of the relationship between the use of CPRmeter (R) device and the quality of chest compressions in a simulated cardiopulmonary resuscitation
    Calvo-Buey, J. A.
    Calvo-Marcos, D.
    Marcos-Camina, R. M.
    ENFERMERIA INTENSIVA, 2016, 27 (01): : 13 - 21
  • [46] Miniaturized Chest Compressor Improves Cerebral Perfusion Without Increases in Intracranial Pressure During Cardiopulmonary Resuscitation in a Porcine Model
    Xu, Jiefeng
    Hu, Xianwen
    Wu, Xiaobo
    Sun, Shijie
    Tang, Wanchun
    CIRCULATION, 2013, 128 (22)
  • [47] Haemodynamic effects of adrenaline (epinephrine) depend on chest compression quality during cardiopulmonary resuscitation in pigs
    Pytte, Morten
    Kramer-Johansen, Jo
    Eilevstjonn, Joar
    Eriksen, Morten
    Stromme, Taevje A.
    Godang, Kristin
    Wik, Lars
    Steen, Petter Andreas
    Sunde, Kjetil
    RESUSCITATION, 2006, 71 (03) : 369 - 378
  • [48] A Comparison of Chest Compression Quality Delivered During On-Scene and Ground Transport Cardiopulmonary Resuscitation
    Russi, Christopher S.
    Myers, Lucas A.
    Kolb, Logan J.
    Lohse, Christine M.
    Hess, Erik P.
    White, Roger D.
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2016, 17 (05) : 634 - 639
  • [49] A new physiological model for studying the effect of chest compression and ventilation during cardiopulmonary resuscitation: The Thiel cadaver
    Charbonney, Emmanuel
    Delisle, Stephane
    Savary, Dominique
    Bronchti, Gilles
    Rigollot, Marceau
    Drouet, Adrien
    Badat, Bilal
    Ouellet, Paul
    Gosselin, Patrice
    Mercat, Alain
    Brochard, Laurent
    Richard, Jean-Christophe M.
    RESUSCITATION, 2018, 125 : 135 - 142
  • [50] Continuous mechanical chest compression during in-hospital cardiopulmonary resuscitation of patients with pulseless electrical activity
    Bonnemeier, Hendrik
    Simonis, Gregor
    Olivecrona, Goran
    Weidtmann, Britta
    Gotberg, Matthias
    Weitz, Gunther
    Gerling, Ivana
    Strasser, Ruth
    Frey, Norbert
    RESUSCITATION, 2011, 82 (02) : 155 - 159