High-precision compton imaging of 4.4 MeV prompt gamma-ray toward an on-line monitor for proton therapy

被引:20
作者
Mochizuki, S. [1 ]
Kataoka, J. [1 ]
Koide, A. [1 ]
Fujieda, K. [1 ]
Maruhashi, T. [1 ]
Kurihara, T. [1 ]
Sueoka, K. [1 ]
Tagawa, L. [1 ]
Yoneyama, M. [1 ]
Inaniwa, T. [2 ]
机构
[1] Waseda Univ, Shinjuku Ku, Tokyo, Japan
[2] Natl Inst Radiol Sci, Chiba, Japan
基金
日本学术振兴会;
关键词
Prompt gamma-ray imaging; Compton camera; MPPC; Proton therapy; RANGE VERIFICATION; SLIT CAMERA;
D O I
10.1016/j.nima.2018.11.032
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Proton therapy is a widely used and effective treatment for cancer. A high-dose concentration of proton beam reduces damage to normal tissues. However, it also requires a high accuracy of irradiation. PET is generally used to verify the proton range after irradiation, but, the distributions of positrons and the energy deposited by protons are not similar to each other. Recently, prompt gamma-ray imaging has attracted attention as a new, online imaging technique. In particular, 4.4 MeV gamma rays emitted from C-12* is one of the best probes to monitor the proton dose, however imaging techniques are far from established. We have developed a novel, 3-D position sensitive Compton camera based on Ce:GAGG scintillators coupled with multi-pixel photon counter (MPPC) arrays, thus making it optimized for imaging in the 1-10 MeV range. The angular resolution is 5 degrees (FWHM) at 4.4 MeV. We have established various methods to discriminate multiple-Compton and escape events, both of which can be critical backgrounds for precise imaging of prompt gamma rays. By irradiating a 70 MeV proton beam on the PMMA phantom, we demonstrated that 4.4 MeV gamma ray image is sharply concentrated on the Bragg peak, as was expected from the PHITS simulation.
引用
收藏
页码:43 / 45
页数:3
相关论文
共 8 条
  • [1] Development of a Dual-Sided Readout DOI-PET Module Using Large-Area Monolithic MPPC-Arrays
    Kishimoto, Aya
    Kataoka, Jun
    Kato, Takuya
    Miura, Takamasa
    Nakamori, Takeshi
    Kamada, Kei
    Nakamura, Shigeyuki
    Sato, Kenichi
    Ishikawa, Yoshitaka
    Yamamura, Kazuhisa
    Kawabata, Nobuyuki
    Yamamoto, Seiichi
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (01) : 38 - 43
  • [2] Koide A., 2017, NIM A
  • [3] Precision imaging of 4.4 MeV gamma rays using a 3-D position sensitive Compton camera
    Koide, Ayako
    Kataoka, Jun
    Masuda, Takamitsu
    Mochizuki, Saku
    Taya, Takanori
    Sueoka, Koki
    Tagawa, Leo
    Fujieda, Kazuya
    Maruhashi, Takuya
    Kurihara, Takuya
    Inaniwa, Taku
    [J]. SCIENTIFIC REPORTS, 2018, 8
  • [4] Prompt gamma detection for range verification in proton therapy
    Kurosawa, Shunsuke
    Kubo, Hidetoshi
    Ueno, Kazuki
    Kabuki, Shigeto
    Iwaki, Satoru
    Takahashi, Michiaki
    Taniue, Kojiro
    Higashi, Naoki
    Miuchi, Kentaro
    Tanimori, Toru
    Kim, Dogyun
    Kim, Jongwon
    [J]. CURRENT APPLIED PHYSICS, 2012, 12 (02) : 364 - 368
  • [5] Time-resolved imaging of prompt-gamma rays for proton range verification using a knife-edge slit camera based on digital photon counters
    Lopes, Patricia Cambraia
    Clementel, Enrico
    Crespo, Paulo
    Henrotin, Sebastien
    Huizenga, Jan
    Janssens, Guillaume
    Parodi, Katia
    Prieels, Damien
    Roellinghoff, Frauke
    Smeets, Julien
    Stichelbaut, Frederic
    Schaart, Dennis R.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (15) : 6063 - 6085
  • [6] Mashayekhi M, 2017, REP PRACT ONCOL RADI, V22, P52, DOI 10.1016/j.rpor.2016.10.004
  • [7] Experimental study on the feasibility of in-beam PET for accurate monitoring of proton therapy
    Parodi, K
    Pönisch, F
    Enghardt, W
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) : 778 - 786
  • [8] Prompt gamma imaging with a slit camera for real-time range control in proton therapy
    Smeets, J.
    Roellinghoff, F.
    Prieels, D.
    Stichelbaut, F.
    Benilov, A.
    Busca, P.
    Fiorini, C.
    Peloso, R.
    Basilavecchia, M.
    Frizzi, T.
    Dehaes, J. C.
    Dubus, A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (11) : 3371 - 3405