Impact of plasma volume status on mortality following left ventricular assist device implantation

被引:3
作者
Imamura, Teruhiko [1 ,2 ]
Narang, Nikhil [3 ]
Combs, Pamela [4 ]
Siddiqi, Umar [4 ]
Mirzai, Saeid [4 ]
Stonebraker, Corinne [4 ]
Bullard, Heather [5 ]
Simone, Pamela [5 ]
Jeevanandam, Valluvan [4 ]
机构
[1] Univ Chicago, Med Ctr, Dept Med, Chicago, IL 60637 USA
[2] Univ Toyama, Dept Internal Med 2, 2630 Sugitani, Toyama 9300194, Japan
[3] Christ Med Ctr, Oak Lawn, IL USA
[4] Univ Chicago, Med Ctr, Dept Surg, Chicago, IL 60637 USA
[5] Univ Chicago, Med Ctr, Dept Pharm, Chicago, IL 60637 USA
关键词
congestion; hemodynamics; mechanical circulatory support; plasma volume; HEART-FAILURE; SUPPORT; SOCIETY;
D O I
10.1111/aor.13878
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Worsening systemic congestion is often the central trigger of hospitalization in patients with heart failure. However, accurate assessment of congestion is challenging. The prognostic impact of systemic congestion following durable continuous-flow left ventricular assist device (LVAD) implantation remains unknown. Consecutive patients who received durable continuous-flow LVAD implantation between January 2014 and June 2017 and were followed for 1 year were included. The association of preoperative plasma volume status, which was calculated using patients' body weight and hematocrit and expressed as a deviation from ideal plasma volume, with 1-year mortality following LVAD implantation was investigated. In total, 186 patients (median 57 years and 138 males) were included. Baseline plasma volume status was -30.1% (-37.1%, -19.4%) on median. Eighty-eight patients (47%) had higher plasma volume status (>-29.8%), and their 1-year survival was significantly lower than those without (67% vs. 87%, P = .001). High plasma volume status was an independent predictor of 1-year death with an adjusted hazard ratio of 4.52 (95% confidence interval 1.52-13.5). Baseline systemic congestion, as defined by the high plasma volume status, was associated with higher mortality following durable continuous-flow LVAD implantation. The implication of improving preoperative plasma volume remains an area of needed investigation.
引用
收藏
页码:587 / 592
页数:6
相关论文
共 15 条
[1]   Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: a randomised controlled trial [J].
Abraham, William T. ;
Adamson, Philip B. ;
Bourge, Robert C. ;
Aaron, Mark F. ;
Costanzo, Maria Rosa ;
Stevenson, Lynne W. ;
Strickland, Warren ;
Neelagaru, Suresh ;
Raval, Nirav ;
Krueger, Steven ;
Weiner, Stanislav ;
Shavelle, David ;
Jeffries, Bradley ;
Yadav, Jay S. .
LANCET, 2011, 377 (9766) :658-666
[2]   The impact of subclinical congestion on the outcome of patients undergoing transcatheter aortic valve implantation [J].
Adlbrecht, Christopher ;
Piringer, Felix ;
Resar, Jon ;
Watzal, Victoria ;
Andreas, Martin ;
Strouhal, Andreas ;
Hasan, Waseem ;
Geisler, Daniela ;
Weiss, Gabriel ;
Grabenwoeger, Martin ;
Delle-Karth, Georg ;
Mach, Markus .
EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2020, 50 (08)
[3]   The 2013 International Society for Heart and Lung Transplantation Guidelines for mechanical circulatory support: Executive summary [J].
Feldman, David ;
Pamboukian, Salpy V. ;
Teuteberg, Jeffrey J. ;
Birks, Emma ;
Lietz, Katherine ;
Moore, Stephanie A. ;
Morgan, Jeffrey A. ;
Arabia, Francisco ;
Bauman, Mary E. ;
Buchholz, Hoger W. ;
Deng, Mario ;
Dickstein, Marc L. ;
El-Banayosy, Aly ;
Elliot, Tonya ;
Goldstein, Daniel. J. ;
Grady, Kathleen L. ;
Jones, Kylie ;
Hryniewicz, Katarzyna ;
John, Ranjit ;
Kaan, Annemarie ;
Kusne, Shimon ;
Loebe, Matthias ;
Massicotte, M. Patricia ;
Moazami, Nader ;
Mohacsi, Paul ;
Mooney, Martha ;
Nelson, Thomas ;
Pagani, Francis ;
Perry, William ;
Potapov, Evgenij V. ;
Rame, Eduardo ;
Russell, Stuart D. ;
Sorensen, Erik N. ;
Sun, Benjamin ;
Strueber, Martin ;
Mangi, Abeel A. ;
Petty, Michael G. ;
Rogers, Joseph .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (02) :157-187
[4]   Integrative Assessment of Congestion in Heart Failure Throughout the Patient Journey [J].
Girerd, Nicolas ;
Seronde, Marie-France ;
Coiro, Stefano ;
Chouihed, Tahar ;
Bilbault, Pascal ;
Braun, Francois ;
Kenizou, David ;
Maillier, Bruno ;
Nazeyrollas, Pierre ;
Roul, Gerard ;
Fillieux, Ludivine ;
Abraham, William T. ;
Januzzi, James, Jr. ;
Sebbag, Laurent ;
Zannad, Faiez ;
Mebazaa, Alexandre ;
Rossignol, Patrick .
JACC-HEART FAILURE, 2018, 6 (04) :273-285
[5]   PREDICTION OF LEAN BODY MASS FROM HEIGHT AND WEIGHT [J].
HUME, R .
JOURNAL OF CLINICAL PATHOLOGY, 1966, 19 (04) :389-&
[6]   Optimal haemodynamics during left ventricular assist device support are associated with reduced haemocompatibility-related adverse events [J].
Imamura, Teruhiko ;
Nguyen, Ann ;
Kim, Gene ;
Raikhelkar, Jayant ;
Sarswat, Nitasha ;
Kalantari, Sara ;
Smith, Bryan ;
Juricek, Colleen ;
Rodgers, Daniel ;
Ota, Takeyoshi ;
Song, Tae ;
Jeevanandam, Valluvan ;
Sayer, Gabriel ;
Uriel, Nir .
EUROPEAN JOURNAL OF HEART FAILURE, 2019, 21 (05) :655-662
[7]   Calculated plasma volume status and prognosis in chronic heart failure [J].
Ling, Hua Zen ;
Flint, Julia ;
Damgaard, Morten ;
Bonfils, Peter K. ;
Cheng, Adrian S. ;
Aggarwal, Suneil ;
Velmurugan, Shanti ;
Mendonca, Michelle ;
Rashid, Mohammed ;
Kang, Swan ;
Papalia, Francesco ;
Weissert, Susanne ;
Coats, Caroline J. ;
Thomas, Martin ;
Kuskowski, Michael ;
Cohn, Jay N. ;
Woldman, Simon ;
Anand, Inder S. ;
Okonko, Darlington O. .
EUROPEAN JOURNAL OF HEART FAILURE, 2015, 17 (01) :35-43
[8]   The Optimal Plasma Volume Status in Heart Failure in Relation to Clinical Outcome [J].
Martens, Pieter ;
Nijst, Petra ;
Dupont, Matthias ;
Mullens, Wilfried .
JOURNAL OF CARDIAC FAILURE, 2019, 25 (04) :240-248
[9]   Calculated plasma volume status and outcomes in patients undergoing coronary bypass graft surgery [J].
Maznyczka, Annette Marie ;
Barakat, Mohamad Fahed ;
Ussen, Bassey ;
Kaura, Amit ;
Abu-Own, Huda ;
Jouhra, Fadi ;
Jaumdally, Hannah ;
Amin-Youssef, George ;
Nicou, Niki ;
Baghai, Max ;
Deshpande, Ranjit ;
Wendler, Olaf ;
Kolvekar, Shyam ;
Okonko, Darlington O. .
HEART, 2019, 105 (13) :1020-1026
[10]   Inadequate left ventricular unloading during ramp is associated with hospitalization or death during left ventricular assist device support [J].
Rosenbaum, Andrew N. ;
Stulak, John M. ;
Clavell, Alfredo L. ;
Behfar, Atta .
ARTIFICIAL ORGANS, 2021, 45 (02) :115-123