Evaluation of left ventricular ejection fraction using through-time radial GRAPPA

被引:28
作者
Aandal, Gunhild [1 ,2 ,3 ]
Nadig, Vidya [4 ]
Yeh, Victoria [5 ]
Rajiah, Prabhakar [1 ,2 ]
Jenkins, Trevor [6 ]
Sattar, Abdus [1 ]
Griswold, Mark [1 ,2 ]
Gulani, Vikas [1 ,2 ]
Gilkeson, Robert C. [1 ,2 ]
Seiberlich, Nicole [1 ]
机构
[1] Case Western Reserve Univ, Cleveland, OH 44106 USA
[2] Univ Hosp, Case Med Ctr, Cleveland, OH USA
[3] Haraldsplass Deaconess Hosp, Bergen, Norway
[4] Case Western Univ, MetroHlth Med Ctr, Cleveland, OH USA
[5] Case Western Reserve Univ, Sch Med, Cleveland, OH 44106 USA
[6] Case Western Reserve Univ, Univ Hosp, Harrington Heart & Vasc Inst, Div Cardiovasc Med,Case Med Ctr, Cleveland, OH 44106 USA
关键词
Real-time imaging; Left ventricular ejection fraction; Cardiovascular magnetic resonance; Cardiac function; CARDIOVASCULAR MAGNETIC-RESONANCE; CARDIAC CINE MRI; RETROSPECTIVE RECONSTRUCTION; MOTION CORRECTION; HEART-FAILURE; BALANCED SSFP; ECHOCARDIOGRAPHY; REPRODUCIBILITY; RESOLUTION; PERFORMANCE;
D O I
10.1186/s12968-014-0079-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The determination of left ventricular ejection fraction using cardiovascular magnetic resonance (CMR) requires a steady cardiac rhythm for electrocardiogram (ECG) gating and multiple breathholds to minimize respiratory motion artifacts, which often leads to scan times of several minutes. The need for gating and breathholding can be eliminated by employing real-time CMR methods such as through-time radial GRAPPA. The aim of this study is to compare left ventricular cardiac functional parameters obtained using current gold-standard breathhold ECG-gated functional scans with non-gated free-breathing real-time imaging using radial GRAPPA, and to determine whether scan time or the occurrence of artifacts are reduced when using this real-time approach. Methods: 63 patients were scanned on a 1.5T CMR scanner using both the standard cardiac functional examination with gating and breathholding and the real-time method. Total scan durations were noted. Through-time radial GRAPPA was employed to reconstruct images from the highly accelerated real-time data. The blood volume in the left ventricle was assessed to determine the end systolic volume (ESV), end diastolic volume (EDV), and ejection fraction (EF) for both methods, and images were rated for the presence of artifacts and quality of specific image features by two cardiac readers. Linear regression analysis, Bland-Altman plots and two-sided t-tests were performed to compare the quantitative parameters. A two-sample t-test was performed to compare the scan durations, and a two-sample test of proportion was used to analyze the presence of artifacts. For the reviewers' ratings the Wilcoxon test for the equality of the scores' distributions was employed. Results: The differences in EF, EDV, and ESV between the gold-standard and real-time methods were not statistically significant (p-values of 0.77, 0.82, and 0.97, respectively). Additionally, the scan time was significantly shorter for the real-time data collection (p< 0.001) and fewer artifacts were reported in the real-time images (p< 0.01). In the qualitative image analysis, reviewers marginally preferred the standard images although some features including cardiac motion were equivalently rated. Conclusion: Real-time functional CMR with through-time radial GRAPPA performed without ECG-gating under free-breathing can be considered as an alternative to gold-standard breathhold cine imaging for the evaluation of ejection fraction in patients.
引用
收藏
页数:13
相关论文
共 31 条
[21]   SNR enhancement of highly-accelerated real-time cardiac MRI acquisitions based on non-local means algorithm [J].
Naegel, Benoit ;
Cernicanu, Alexandru ;
Hyacinthe, Jean-Noel ;
Tognolini, Maurizio ;
Vallee, Jean-Paul .
MEDICAL IMAGE ANALYSIS, 2009, 13 (04) :598-608
[22]   LEFT-VENTRICULAR MEASUREMENTS WITH CINE AND SPIN-ECHO MR IMAGING - A STUDY OF REPRODUCIBILITY WITH VARIANCE COMPONENT ANALYSIS [J].
PATTYNAMA, PMT ;
LAMB, HJ ;
VANDERVELDE, EA ;
VANDERWALL, EE ;
DEROOS, A .
RADIOLOGY, 1993, 187 (01) :261-268
[23]  
Raju VM, 2013, P RSNA 2013 LL CAS T
[24]   Real-time imaging with radial GRAPPA: Implementation on a heterogeneous architecture for low-latency reconstructions [J].
Saybasili, Hans ;
Herzka, Daniel A. ;
Seiberlich, Nicole ;
Griswold, Mark A. .
MAGNETIC RESONANCE IMAGING, 2014, 32 (06) :747-758
[25]  
Sayin O, 2014, JCMR S1, V16, pW6
[26]   Comparison of magnetic resonance real-time imaging of left ventricular function with conventional magnetic resonance imaging and echocardiography [J].
Schalla, S ;
Nagel, E ;
Lehmkuhl, H ;
Klein, C ;
Bornstedt, A ;
Schnackenburg, B ;
Schneider, U ;
Fleck, E .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (01) :95-99
[27]   Improved Radial GRAPPA Calibration for Real-Time Free-Breathing Cardiac Imaging [J].
Seiberlich, Nicole ;
Ehses, Philipp ;
Duerk, Jeff ;
Gilkeson, Robert ;
Griswold, Mark .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (02) :492-505
[28]   A Practical Acceleration Algorithm for Real-Time Imaging [J].
Suembuel, Uygar ;
Santos, Juan M. ;
Pauly, John M. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (12) :2042-2051
[29]   Real-time MRI at a resolution of 20 ms [J].
Uecker, Martin ;
Zhang, Shuo ;
Voit, Dirk ;
Karaus, Alexander ;
Merboldt, Klaus-Dietmar ;
Frahm, Jens .
NMR IN BIOMEDICINE, 2010, 23 (08) :986-994
[30]   Real-time cardiovascular magnetic resonance at 1.5 T using balanced SSFP and 40 ms resolution [J].
Voit, Dirk ;
Zhang, Shuo ;
Unterberg-Buchwald, Christina ;
Sohns, Jan M. ;
Lotz, Joachim ;
Frahm, Jens .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15