Evaluation of left ventricular ejection fraction using through-time radial GRAPPA

被引:28
作者
Aandal, Gunhild [1 ,2 ,3 ]
Nadig, Vidya [4 ]
Yeh, Victoria [5 ]
Rajiah, Prabhakar [1 ,2 ]
Jenkins, Trevor [6 ]
Sattar, Abdus [1 ]
Griswold, Mark [1 ,2 ]
Gulani, Vikas [1 ,2 ]
Gilkeson, Robert C. [1 ,2 ]
Seiberlich, Nicole [1 ]
机构
[1] Case Western Reserve Univ, Cleveland, OH 44106 USA
[2] Univ Hosp, Case Med Ctr, Cleveland, OH USA
[3] Haraldsplass Deaconess Hosp, Bergen, Norway
[4] Case Western Univ, MetroHlth Med Ctr, Cleveland, OH USA
[5] Case Western Reserve Univ, Sch Med, Cleveland, OH 44106 USA
[6] Case Western Reserve Univ, Univ Hosp, Harrington Heart & Vasc Inst, Div Cardiovasc Med,Case Med Ctr, Cleveland, OH 44106 USA
关键词
Real-time imaging; Left ventricular ejection fraction; Cardiovascular magnetic resonance; Cardiac function; CARDIOVASCULAR MAGNETIC-RESONANCE; CARDIAC CINE MRI; RETROSPECTIVE RECONSTRUCTION; MOTION CORRECTION; HEART-FAILURE; BALANCED SSFP; ECHOCARDIOGRAPHY; REPRODUCIBILITY; RESOLUTION; PERFORMANCE;
D O I
10.1186/s12968-014-0079-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The determination of left ventricular ejection fraction using cardiovascular magnetic resonance (CMR) requires a steady cardiac rhythm for electrocardiogram (ECG) gating and multiple breathholds to minimize respiratory motion artifacts, which often leads to scan times of several minutes. The need for gating and breathholding can be eliminated by employing real-time CMR methods such as through-time radial GRAPPA. The aim of this study is to compare left ventricular cardiac functional parameters obtained using current gold-standard breathhold ECG-gated functional scans with non-gated free-breathing real-time imaging using radial GRAPPA, and to determine whether scan time or the occurrence of artifacts are reduced when using this real-time approach. Methods: 63 patients were scanned on a 1.5T CMR scanner using both the standard cardiac functional examination with gating and breathholding and the real-time method. Total scan durations were noted. Through-time radial GRAPPA was employed to reconstruct images from the highly accelerated real-time data. The blood volume in the left ventricle was assessed to determine the end systolic volume (ESV), end diastolic volume (EDV), and ejection fraction (EF) for both methods, and images were rated for the presence of artifacts and quality of specific image features by two cardiac readers. Linear regression analysis, Bland-Altman plots and two-sided t-tests were performed to compare the quantitative parameters. A two-sample t-test was performed to compare the scan durations, and a two-sample test of proportion was used to analyze the presence of artifacts. For the reviewers' ratings the Wilcoxon test for the equality of the scores' distributions was employed. Results: The differences in EF, EDV, and ESV between the gold-standard and real-time methods were not statistically significant (p-values of 0.77, 0.82, and 0.97, respectively). Additionally, the scan time was significantly shorter for the real-time data collection (p< 0.001) and fewer artifacts were reported in the real-time images (p< 0.01). In the qualitative image analysis, reviewers marginally preferred the standard images although some features including cardiac motion were equivalently rated. Conclusion: Real-time functional CMR with through-time radial GRAPPA performed without ECG-gating under free-breathing can be considered as an alternative to gold-standard breathhold cine imaging for the evaluation of ejection fraction in patients.
引用
收藏
页数:13
相关论文
共 31 条
[1]   True real-time cardiac MRI in free breathing without ECG synchronization using a novel sequence with radial k-space sampling and balanced SSFP contrast mode [J].
Bauer, Ralf W. ;
Radtke, Isabel ;
Block, Kai T. ;
Larson, Maya C. ;
Kerl, J. Matthias ;
Hammerstingl, Renate ;
Graf, Thomas G. ;
Vogl, Thomas J. ;
Zhang, Shuo .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05) :1059-1067
[2]   Free breathing cardiac real-time cine MR without ECG triggering [J].
Beer, Meinrad ;
Stamm, Heimo ;
Machann, Wolfram ;
Weng, Andreas ;
Goltz, Jan P. ;
Breunig, Frank ;
Weidemann, Frank ;
Hahn, Dietbert ;
Koestler, Herbert .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 145 (02) :380-382
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Real-Time Cardiac MRI using Prior Spatial-Spectral Information [J].
Brinegar, Cornelius ;
Zhang, Haosen ;
Wu, Yi-Jen L. ;
Foley, Lesley M. ;
Hitchens, T. Kevin ;
Ye, Qing ;
Pocci, Darren ;
Lam, Fan ;
Ho, Chien ;
Liang, Zhi-Pei .
2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, :4383-+
[5]   EFFECT OF INTRA-THORACIC PRESSURE ON LEFT-VENTRICULAR PERFORMANCE [J].
BUDA, AJ ;
PINSKY, MR ;
INGELS, NB ;
DAUGHTERS, GT ;
STINSON, EB ;
ALDERMAN, EL .
NEW ENGLAND JOURNAL OF MEDICINE, 1979, 301 (09) :453-459
[6]   REPRODUCIBILITY OF ANGIOGRAPHIC LEFT VENTRICULAR EJECTION FRACTION IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
COHN, PF ;
LEVINE, JA ;
BERGERON, GA ;
GORLIN, R .
AMERICAN HEART JOURNAL, 1974, 88 (06) :713-720
[7]   Application of the Karhunen-Loeve transform temporal image filter to reduce noise in real-time cardiac cine MRI [J].
Ding, Yu ;
Chung, Yiu-Cho ;
Raman, Subha V. ;
Simonetti, Orlando P. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (12) :3909-3922
[8]   Performance of 3-Dimensional Echocardiography in Measuring Left Ventricular Volumes and Ejection Fraction [J].
Dorosz, Jennifer L. ;
Lezotte, Dennis C. ;
Weitzenkamp, David A. ;
Allen, Larry A. ;
Salcedo, Ernesto E. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (20) :1799-1808
[9]  
Feng L, 2012, MAGN RESON MED, DOI [10.1002/mrm.24440, DOI 10.1002/MRM.24440.]
[10]   On NUFFT-based gridding for non-Cartesian MRI [J].
Fessler, Jeffrey A. .
JOURNAL OF MAGNETIC RESONANCE, 2007, 188 (02) :191-195