Label-free electrochemical immunosensor for detection of tumor necrosis factor et based on fullerene-functionalized carbon nanotubes/ionic liquid

被引:64
作者
Mazloum-Ardakani, Mohammad [1 ]
Hosseinzadeh, Laleh [1 ]
Khoshroo, Alireza [1 ]
机构
[1] Yazd Univ, Fac Sci, Dept Chem, Yazd 89195741, Iran
基金
美国国家科学基金会;
关键词
Kinetic parameters; Fullerene-functionalized carbon nanotubes; Ionic liquid; Electrochemical immunosensor; Tumor necrosis factor alpha; Catechol; SCREEN-PRINTED ELECTRODE; GOLD NANOPARTICLES; HUMAN SERUM; TITANIUM-DIOXIDE; IONIC LIQUIDS; FACTOR-ALPHA; L-CYSTEINE; SENSOR; ACID; NANOCOMPOSITE;
D O I
10.1016/j.jelechem.2015.09.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel and sensitive label-free electrochemical immunosensor was developed for enzyme-free determination of biomarker tumor necrosis factor a antigen (TNF-alpha) based on entrapping of a TNF-alpha antibody onto nanocomposite containing fullerene-functionalized multiwalled carbon nanotubes and ionic liquid (1-butyl-3-methylimidazolium bis (trifluoromethyl sulfonyl)imide) (C-60-CNTs-IL). C-60-CNTs-IL was used as a desirable sensor platform and excellent electrocatalyst for oxidation of catechol as a probe in an immunosensor. Determination of TNF-alpha was based on its obstruction of the electrocatalytic oxidation of catechol by C-60-CNTs-IL after binding to the surface of an electrode through interaction with the anti-TNF-alpha. The protein layers on the modified electrode generated a barrier for electrontransfer; we demonstrated the effect of immobilized protein layers and modification of the electrode on the kinetic parameters in every step of immunosensor construction. Various kinetic parameters such as electrode surface area (A), diffusion coefficient (D) and electron-transfer rate constant (k(s)) were also studied and calculated in the aqueous solution. Under the optimal conditions, the results demonstrated that this electrochemical immunosensor had a dynamic range of between 5.0 pg/mL to 75 pg/mL with a low detection limit of 2.0 pg/mL for TNF-alpha. The fabricated immunosensor was successfully applied to the determination of TNF-alpha in serum samples. The obtained results showed the change of kinetic parameters due to the effect of each step of immunosensor fabrication and the fabricated immunosensor demonstrates the promising applications in protein diagnostics and bioassay. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:58 / 64
页数:7
相关论文
共 40 条
[1]  
Bard A.J., 2001, Electrochemical Methods: Fundamentals and Applications, V2
[2]   ASSAYING TUMOR-NECROSIS-FACTOR CONCENTRATIONS IN HUMAN SERUM - A WHO INTERNATIONAL COLLABORATIVE STUDY [J].
DEKOSSODO, S ;
HOUBA, V ;
GRAU, GE ;
WAAGE, A ;
MEAGER, A ;
KRAMER, SM ;
YAMAZAKI, S ;
KWIATKOWSKI, D ;
LAMCHE, H ;
KLEINHAMMER, G ;
EBERLE, W ;
VANDERMEER, JWM ;
BUURMAN, W ;
TEPPO, AM ;
STEPHENS, S .
JOURNAL OF IMMUNOLOGICAL METHODS, 1995, 182 (01) :107-114
[3]   Adipose tissue as an endocrine organ [J].
Galic, Sandra ;
Oakhill, Jon S. ;
Steinberg, Gregory R. .
MOLECULAR AND CELLULAR ENDOCRINOLOGY, 2010, 316 (02) :129-139
[4]   One step electrochemically deposited nanocomposite film of chitosan-carbon nanotubes-gold nanoparticles for carcinoembryonic antigen immunosensor application [J].
Gao, Xia ;
Zhang, Yiming ;
Wu, Qi ;
Chen, Huan ;
Chen, Zhichun ;
Lin, Xianfu .
TALANTA, 2011, 85 (04) :1980-1985
[5]   Amperometric immunosensor of Brucella abortus CE-protein antigen shows post-zone phenomena [J].
Gupta, Ajay Kumar ;
Rao, Vepa Kameswara ;
Selvam, D. T. ;
Kumar, Ashu ;
Jain, Rajeev .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 717 :83-89
[6]   Ultrasensitive All-Carbon Photoelectrochemical Bioprobes for Zeptomole Immunosensing of Tumor Markers by an Inexpensive Visible Laser Light [J].
Hu, Chengguo ;
Zheng, Jinou ;
Su, Xiaoyang ;
Wang, Juan ;
Wu, Wangze ;
Hu, Shengshui .
ANALYTICAL CHEMISTRY, 2013, 85 (21) :10612-10619
[7]   Increased Electrocatalyzed Performance through Dendrimer-Encapsulated Gold Nanoparticles and Carbon Nanotube-Assisted Multiple Bienzymatic Labels: Highly Sensitive Electrochemical Immunosensor for Protein Detection [J].
Jeong, Bongjin ;
Akter, Rashida ;
Han, Oc Hee ;
Rhee, Choong Kyun ;
Rahman, Md Aminur .
ANALYTICAL CHEMISTRY, 2013, 85 (03) :1784-1791
[8]   Graphite impurities cause the observed 'electrocatalysis' seen at C60 modified glassy carbon electrodes in respect of the oxidation of L-cysteine [J].
Kachoosangi, RT ;
Banks, CE ;
Compton, RG .
ANALYTICA CHIMICA ACTA, 2006, 566 (01) :1-4
[9]   GENERAL EXPRESSION OF THE LINEAR POTENTIAL SWEEP VOLTAMMOGRAM IN THE CASE OF DIFFUSIONLESS ELECTROCHEMICAL SYSTEMS [J].
LAVIRON, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1979, 101 (01) :19-28
[10]   Complementary detection of prostate-specific antigen using ln2O3 nanowires and carbon nanotubes [J].
Li, C ;
Curreli, M ;
Lin, H ;
Lei, B ;
Ishikawa, FN ;
Datar, R ;
Cote, RJ ;
Thompson, ME ;
Zhou, CW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (36) :12484-12485