Simultaneous left and right ventricle segmentation using topology preserving level sets

被引:21
作者
Arrieta, Cristobal [1 ,2 ]
Uribe, Sergio [2 ,3 ]
Sing-Long, Carlos [2 ,4 ,5 ,6 ,7 ]
Hurtado, Daniel [2 ,8 ]
Andia, Marcelo [2 ,3 ]
Irarrazaval, Pablo [1 ,2 ]
Tejos, Cristian [1 ,2 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Elect Engn, Santiago, Chile
[2] Pontificia Univ Catolica Chile, Biomed Imaging Ctr, Santiago, Chile
[3] Pontificia Univ Catolica Chile, Sch Med, Dept Radiol, Santiago, Chile
[4] Stanford Univ, Inst Computat & Math Engn, Stanford, CA 94305 USA
[5] Pontificia Univ Catolica Chile, Sch Engn, Inst Biol & Med Engn, Santiago, Chile
[6] Pontificia Univ Catolica Chile, Sch Med, Inst Biol & Med Engn, Santiago, Chile
[7] Pontificia Univ Catolica Chile, Sch Biol Sci, Inst Biol & Med Engn, Santiago, Chile
[8] Pontificia Univ Catolica Chile, Struct & Geotech Engn Dept, Santiago, Chile
关键词
Cardiac segmentation; Left and right ventricles; Level sets; Preserved topology; GRADIENT VECTOR FLOW; MAGNETIC-RESONANCE; HEART; VOLUMES;
D O I
10.1016/j.bspc.2016.11.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cardiovascular Magnetic Resonance (CMR) has been successfully used in clinical practice to evaluate the cardiac function. Heart functional indexes, such as end-systolic volume and end-diastolic volume, are usually computed from manual segmentations performed by an expert using short-axis cine MR images. This process is tedious and time consuming. Despite semi-automatic methods have been proposed, including pixel-based, atlas-based, active contours and level sets, most of them allow the segmentation of only one ventricle at a time, and methods for segmenting both ventricles simultaneously tend to fail in the presence of abnormal anatomies. We propose a method based on level sets with preserved topology that allows simultaneous, fast and accurate segmentations of the left and right ventricles. We compared our segmentation results of the left and right ventricles with those obtained with clinically validated software (Viewforum, Philips, Best and Segment, Medviso, Lund) using two-tailored paired t-test, Pearson's correlation, Bland-Altman plots of standard functional indexes and voxel-by-voxel analysis with Dice. Two-tailored paired t-test showed no significant difference between our method and gold standards (P<0.05), Pearson's correlation showed a high correlation of our measurement with gold standards (over 0.98), Dice showed an average agreement over or equal to 0.90 and Bland Altman analysis showed that our method has a good agreement with the gold standard segmentations. We were able to segment both ventricles simultaneously, without any training process and taking less than 15 s per cardiac phase. The process was semi-automatic with only minor manual corrections needed at the basal slices. Our results show high levels of accuracy considering functional indexes and also in a voxel-to-voxel comparison. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:88 / 95
页数:8
相关论文
共 38 条
[1]  
Bellenger N. G., EUR HEART J, V21
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[4]   Geodesic active contours [J].
Caselles, V ;
Kimmel, R ;
Sapiro, G .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1997, 22 (01) :61-79
[5]   Active contours without edges [J].
Chan, TF ;
Vese, LA .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2001, 10 (02) :266-277
[6]   Dynamic directional gradient vector flow for snakes [J].
Cheng, Jierong ;
Foo, Say Wei .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2006, 15 (06) :1563-1571
[7]   MEASURES OF THE AMOUNT OF ECOLOGIC ASSOCIATION BETWEEN SPECIES [J].
DICE, LR .
ECOLOGY, 1945, 26 (03) :297-302
[8]   An automated myocardial segmentation in cardiac MRI [J].
El Berbari, R. ;
Bloch, I. ;
Redheuil, A. ;
Angelini, E. ;
Mousseaux, E. ;
Frouin, F. ;
Herment, A. .
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, :4508-+
[9]   DYNAMIC-PROGRAMMING FOR DETECTING, TRACKING, AND MATCHING DEFORMABLE CONTOURS [J].
GEIGER, D ;
GUPTA, A ;
COSTA, LA ;
VLONTZOS, J .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1995, 17 (03) :294-302
[10]   Automatic cardiac ventricle segmentation in MR images: a validation study [J].
Grosgeorge, Damien ;
Petitjean, Caroline ;
Caudron, Jerome ;
Fares, Jeannette ;
Dacher, Jean-Nicolas .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2011, 6 (05) :573-581