Accelerated solvent extraction method for the quantification of polycyclic aromatic hydrocarbons in cocoa beans by gas chromatography-mass spectrometry

被引:23
作者
Cassimiro Belo, Renata Franca [1 ]
Figueiredob, Julia Pereira [2 ]
Nunes, Carolina Mariana [2 ]
Pissinatti, Rafael [2 ]
Carvalho de Souza, Scheilla Vitorino [1 ]
Junqueira, Roberto Goncalves [1 ]
机构
[1] Fed Univ Minas Gerais UFMG, Fac Pharm FAFAR, Dept Food Sci, Av Antonio Carlos 6627,Campus UFMG, BR-31270010 Belo Horizonte, MG, Brazil
[2] Minist Agr, Natl Lab Minas Gerais LANAGRO MG, Livestock & Food Supply MAPA, Av Romulo Joviano S-N, BR-33600000 Pedro Leopoldo, MG, Brazil
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2017年 / 1053卷
关键词
Cocoa bean; Polycyclic aromatic hydrocarbons; Single laboratory method validation; Accelerated solvent extraction; Gas chromatography; Mass spectrometry; SINGLE-LABORATORY VALIDATION; PAHS; FOOD; OPTIMIZATION; GUIDELINES; CLEANUP; SAMPLES; OILS;
D O I
10.1016/j.jchromb.2017.03.017
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An accelerated solvent extraction (ASE) procedure for use with gas chromatography-mass spectrometry (GC-MS) was optimized for the determination of eight polycyclic aromatic hydrocarbons (PAHs) in cocoa beans. Plackett-Burman and rotatable central composite design (RCCD) indicated that three variables affected the recoveries of PAHs during the extraction and purification steps: agitation time in the second liquid-liquid partition, weight of silica gel in the column, and volume of hexane for PAH elution from the column. After obtaining the optimal conditions, a single laboratory method validation was performed. Linearity was demonstrated for benzo[a]pyrene in the concentration range from 0.5 to 8.0 mg kg(-1) of sample, corresponding to 1.25-20.0 mu g kg(-1) of cocoa on a fat basis. For the other analytes, linearity was observed from 0.75 to 8.0 mu g kg(-1) of sample (1.88-20.0 mu g kg(-1) of cocoa on a fat basis). Significant matrix effects were found for chrysene and benzo[blfluoranthene. The precision of the method was verified with relative standard deviations (RSDs) ranging from 2.57 to 14.13% and from 4.36 to 19.77% under repeatability and intermediate precision conditions, respectively. The average recoveries of the eight PAHs ranged from 74.99 to 109.73%. These parameters, limits and measurement uncertainties met the performance criteria established by European Union regulations, except for the theoretical limit of detection for chrysene. The method was applied to the analysis of samples of Brazilian cocoa beans, and only one sample was found to have a PAH content above the maximum limit defined by the European Union legislation. This optimized and validated method is intended to be used as part of the official Brazilian monitoring programs investigating contaminants and residues in food. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:87 / 100
页数:14
相关论文
共 39 条
  • [1] Abdel-Shafy Hussein I., 2016, Egyptian Journal of Petroleum, V25, P107, DOI 10.1016/j.ejpe.2015.03.011
  • [3] [Anonymous], 1946, Biometrika, DOI [DOI 10.2307/2332195, 10.2307/2332195, DOI 10.1093/BIOMET/33.4.305]
  • [4] Review of PAH contamination in food products and their health hazards
    Bansal, Vasudha
    Kim, Ki-Hyun
    [J]. ENVIRONMENT INTERNATIONAL, 2015, 84 : 26 - 38
  • [5] Cancer risk assessment, indicators, and guidelines for polycyclic aromatic hydrocarbons in the ambient air
    Boström, CE
    Gerde, P
    Hanberg, A
    Jernström, B
    Johansson, C
    Kyrklund, T
    Rannug, A
    Törnqvist, M
    Victorin, K
    Westerholm, R
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 2002, 110 : 451 - 488
  • [6] MULTI-FACTOR EXPERIMENTAL-DESIGNS FOR EXPLORING RESPONSE SURFACES
    BOX, GEP
    HUNTER, JS
    [J]. ANNALS OF MATHEMATICAL STATISTICS, 1957, 28 (01): : 195 - 241
  • [7] Optimization of sample clean-up for the GC-C-IRMS and GC-IT-MS analyses of PAHs from air particulate matter
    Buczynska, Anna J.
    Geypens, Benny
    Van Grieken, Rene
    De Wael, Karolien
    [J]. MICROCHEMICAL JOURNAL, 2015, 119 : 83 - 92
  • [8] HPLC-FLD Simultaneous Determination of 13 Polycyclic Aromatic Hydrocarbons: Validation of an Analytical Procedure for Soybean Oils
    Camargo, Monica C. R.
    Antoniolli, Paula R.
    Vicente, Eduardo
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2011, 22 (07) : 1354 - 1361
  • [9] Single laboratory validation of a SPE method for the determination of PAHs in edible oils by GC-MS
    Cassimiro Belo, Renata Franca
    Nunes, Carolina Mariana
    dos Santos, Eleonora Vieira
    Augusti, Daniella Vasconcellos
    Pissinatti, Rafael
    [J]. ANALYTICAL METHODS, 2012, 4 (12) : 4068 - 4076
  • [10] In-house method validation: application in arsenic analysis
    de Souza, Scheilla V. C.
    Pinto, Carlos T.
    Junqueira, Roberto G.
    [J]. JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2007, 20 (3-4) : 241 - 247