The Effect of Simultaneous Antigravity Treadmill Training and Electrical Muscle Stimulation After Total Hip Arthroplasty: Short Follow-Up Time

被引:2
作者
Mikami, Yukio [1 ]
Orita, Naoya [2 ]
Yamasaki, Talcuma [3 ]
Kamijo, Yoshiichiro [4 ]
Kimura, Hiroaki [1 ]
Adachi, Nobuo [3 ]
机构
[1] Hiroshima Univ Hosp, Dept Rehabil Med, Hiroshima, Japan
[2] Hiroshima Univ Hosp, Dept Clin Practice & Support, Div Rehabil, Hiroshima, Japan
[3] Hiroshima Univ, Grad Sch Biomed Sci, Dept Orthopaed Surg, Hiroshima, Japan
[4] Wakayama Med Univ, Dept Rehabil Med, Wakayama, Japan
来源
ANNALS OF REHABILITATION MEDICINE-ARM | 2019年 / 43卷 / 04期
关键词
Anti-gravity treadmill; Low frequency electrical stimulation device; Hip osteoarthritis; Total hip arthroplasty; BODY POSITIVE-PRESSURE; KNEE; REHABILITATION; OSTEOARTHRITIS; REPLACEMENT; OUTCOMES; SYSTEM;
D O I
10.5535/arm.2019.43.4.474
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective To assess the effectiveness of our devised hybrid physiotherapy regime using an anti-gravity treadmill and a low-frequency electrical stimulation device, as measured in patients with hip osteoarthritis after total hip arthroplasty (THA). Methods The outcomes of the postoperative rehabilitation in 44 patients who underwent THA for hip osteoarthritis were retrospectively examined. The conventional group (n=22) underwent the postoperative rehabilitation according to our protocol, while the hybrid group (n=22) underwent the same training, along with training on an anti-gravity treadmill and training using a low-frequency therapeutic device. The outcome measures were recorded and reviewed with the Numerical Rating Scale for pain, which rates pain on an 11-point scale from 0 to 10, surgical side knee joint extension force, 10-m walking test, Timed Up and Go test, and the 6-minute walking distance (6MD). The outcome measurement was taken 2 weeks after conducting pre-operation and antigravity treadmill training and electrical muscle stimulation, and compared the respective results. Results At the timeframe of 2 weeks from the surgery after conducting a devised hybrid physiotherapy, the values of knee extension muscle strength and 6MD were not worse in the hybrid group than conventional group. In the evaluation at 2 weeks after surgery, the knee extension muscle strength and 6MD values significantly decreased compared with the preoperative values only in the conventional group. Conclusion Lower limb muscular strength and endurance were maintained in the hybrid group, which suggested that hybrid physiotherapy could maintain physical functions early after THA operation.
引用
收藏
页码:474 / 482
页数:9
相关论文
共 27 条
[1]   Incidence of certified need of care in the long-term care insurance system and its risk factors in the elderly of Japanese population-based cohorts: The ROAD study [J].
Akune, Toru ;
Muraki, Shigeyuki ;
Oka, Hiroyuki ;
Tanaka, Sakae ;
Kawaguchi, Hiroshi ;
Tokimura, Fumiaki ;
Yoshida, Hideyo ;
Suzuki, Takao ;
Nakamura, Kozo ;
Yoshimura, Noriko .
GERIATRICS & GERONTOLOGY INTERNATIONAL, 2014, 14 (03) :695-701
[2]  
Bugbee William D, 2016, Am J Orthop (Belle Mead NJ), V45, pE167
[3]  
Coudeyre E., 2007, Annales de Readaptation et de Medecine Physique, V50, P189, DOI 10.1016/j.annrmp.2007.02.002
[4]   Ambulation in simulated fractional gravity using lower body positive pressure: cardiovascular safety and gait analyses [J].
Cutuk, Adnan ;
Groppo, Eli R. ;
Quigley, Edward J. ;
White, Klane W. ;
Pedowitz, Robert A. ;
Hargens, Alan R. .
JOURNAL OF APPLIED PHYSIOLOGY, 2006, 101 (03) :771-777
[5]   Lower body positive-pressure exercise after knee surgery [J].
Eastlack, RK ;
Hargens, AR ;
Groppo, ER ;
Steinbach, GC ;
White, MK ;
Pedowitz, RA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (431) :213-219
[6]  
Fortin PR, 1999, ARTHRITIS RHEUM, V42, P1722, DOI 10.1002/1529-0131(199908)42:8<1722::AID-ANR22>3.0.CO
[7]  
2-R
[8]   Prospective study of physical activity and quality of life in Japanese women undergoing total hip arthroplasty [J].
Fujita, Kimie ;
Makimoto, Kiyoko ;
Tanaka, Riki ;
Mawatari, Masaaki ;
Hotokebuchi, Takao .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2013, 18 (01) :45-53
[9]   Effects of Velocity and Weight Support on Ground Reaction Forces and Metabolic Power During Running [J].
Grabowski, Allena M. ;
Kram, Rodger .
JOURNAL OF APPLIED BIOMECHANICS, 2008, 24 (03) :288-297
[10]   Low-Frequency Electric Muscle Stimulation Combined With Physical Therapy After Total Hip Arthroplasty for Hip Osteoarthritis in Elderly Patients: A Randomized Controlled Trial [J].
Gremeaux, Vincent ;
Renault, Julien ;
Pardon, Laurent ;
Deley, Gaelle ;
Lepers, Romuald ;
Casillas, Jean-Marie .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2008, 89 (12) :2265-2273