Dispersed phase hold-up, effective interfacial area and Sauter mean drop diameter in annular centrifugal extractors

被引:41
作者
Kadam, B. D. [1 ]
Joshi, J. B. [1 ]
Koganti, S. B. [2 ]
Patil, R. N. [3 ]
机构
[1] Univ Mumbai, Inst Chem Technol, Bombay 400019, Maharashtra, India
[2] Indira Gandhi Ctr Atom Res, Kalpakkam 603102, Tamil Nadu, India
[3] Techno Force Pvt Ltd, Nasik 422010, India
关键词
Annular centrifugal extractor; Dispersed phase hold-up; Effective interfacial area; Drop diameter; Power number; Taylor-Couette flow; CONTACTOR; FLOW;
D O I
10.1016/j.cherd.2009.03.005
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Annular centrifugal extractors (ACE), based on the principle of Taylor-Couette flow, offer potential advantages over the existing conventional extraction equipments in many of the engineering applications. In the present work, dispersed phase hold-up (is an element of(D)) and effective interfacial area ((a) under bar) have been measured in 30, 75 and 250 mm rotor diameter annular centrifugal extractors over a wide range of power consumption (0.4 < P/V < 500, kW/m(3)) and physical properties (900 < rho(C) < 1300, kg/m(3); 600 < rho(D) < 1600, kg/m(3); 0.84 < mu(C) < 10, mPa s; 0.6 < mu(D) < 27, mPa s; and 2.2 < sigma < 58, mN/m). From these measurements, Sauter mean drop diameter (d(3,2)) has been estimated. Suitable correlations have been proposed for is an element of(D), (a) under bar, and d(3,2), which are expected to be useful for practicing engineers. Power consumption was also measured for 40, 60 and 100 mm, diameter rotors and an appropriate and simple correlation for power number for ACE has been proposed. (C) 2009 The Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1379 / 1389
页数:11
相关论文
共 36 条
[1]  
ARAFAT HA, 2001, ANL0208
[2]   HIGH-CAPACITY ANNULAR CENTRIFUGAL CONTACTOR [J].
BERNSTEI.GJ ;
GROSVENO.DE ;
LENC, JF ;
LEVITZ, NM .
NUCLEAR TECHNOLOGY, 1973, 20 (03) :200-202
[3]  
Bernstein G.J., 1973, ANL7968
[4]  
Danckwerts P.V., 1970, GAS LIQUID REACTIONS
[5]   LIQUID-LIQUID EXTRACTION ... BETWEEN ROTATING CONCENTRIC CYLINDERS [J].
DAVIS, MW ;
WEBER, EJ .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1960, 52 (11) :929-934
[6]   Residence Time Distribution and Flow Patterns in the Single-Phase Annular Region of Annular Centrifugal Extractor [J].
Deshmukh, Sandesh S. ;
Sathe, Mayur J. ;
Joshi, Jyeshtharaj B. ;
Koganti, Sudhir B. .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2009, 48 (01) :37-46
[7]  
Doraiswami L. K., 1984, HETEROGENEOUS REACTI, V2
[8]   Lipase-catalyzed esterification [J].
Gandhi, NN ;
Patil, NS ;
Sawant, SB ;
Joshi, JB ;
Wangikar, PP ;
Mukesh, D .
CATALYSIS REVIEWS-SCIENCE AND ENGINEERING, 2000, 42 (04) :439-480
[9]  
HASS PA, 1987, AICHE J, V33, P987
[10]   A NEW APPROACH TO CONTINUOUS EMULSION POLYMERIZATION [J].
IMAMURA, T ;
SAITO, K ;
ISHIKURA, S ;
NOMURA, M .
POLYMER INTERNATIONAL, 1993, 30 (02) :203-206