The role of preoperative templating in total knee arthroplasty: Comparison of three prostheses

被引:25
作者
Howcroft, D. W. J.
Fehily, M. J.
Peck, C.
Fox, A.
Dillon, B.
Johnson, D. S.
机构
[1] Stepping Hill Hosp, Stockport NHS Fdn Trust, Stockport SK2 7JE, Lancs, England
[2] Wythenshawe hosp, Manchester, Lancs, England
关键词
template; knee arthroplasty; reliability; accuracy;
D O I
10.1016/j.knee.2006.05.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Templating of preoperative radiographs is routinely recommended prior to knee arthroplasty. We performed this study to assess the reproducibility and accuracy of the templates for three commonly used knee implants (PFC, Kinemax, Scorpio). Six lower limb surgeons templated 10 patients for each of the three designs. The inter- and intra-observer reliability and accuracy was calculated. There was marked variation in the reliability of the templating with the tibial insert scoring better than the femoral and the Kinemax being the most reproducible of the three. In general, the intra-observer scores (kappa- = 0.57-0.8 1) were better than the inter-observer ones (kappa = 0.21-0.60). The Scorpio was the most accurately templated of the three implants, with the percentage correlating with what was actually implanted ranging from 55% to 62% for the femur and 72% to 75% for the tibia, with no templated sizes more than one size different from the actual implant. The other implants ranged from 38% to 42% for the femur and 53% to 58% for the tibia with both having up to 3% more than I size difference from the actual implant. We believe that the use of templating in total knee arthroplasty should be interpreted with caution and we urge the development of more accurate prosthesis sizing techniques. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:427 / 429
页数:3
相关论文
共 15 条
  • [1] The role of pre-operative templating in primary total knee replacement
    Arora, J
    Sharma, S
    Blyth, M
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (03) : 187 - 189
  • [2] Aslam Nadim, 2004, Acta Orthop Belg, V70, P560
  • [3] Reliability of templating in estimating the size of uni-condylar knee arthroplasty
    Bothra, V
    Lemon, G
    Lang, D
    Smith, DM
    Ali, AM
    [J]. JOURNAL OF ARTHROPLASTY, 2003, 18 (06) : 780 - 783
  • [4] *BRIT ORTH ASS, TOT KNEE REPL PBA OR
  • [5] Computer-assisted knee arthroplasty versus a conventional jig-based technique -: A randomised, prospective trial
    Chauhan, SK
    Scott, RG
    Breidahl, W
    Beaver, RJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (03): : 372 - 377
  • [6] The value of preoperative planning for total hip arthroplasty
    Eggli, S
    Pisan, M
    Muller, ME
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (03): : 382 - 390
  • [7] Kinemax total knee arthroplasty - Trial by template
    Heal, J
    Blewitt, N
    [J]. JOURNAL OF ARTHROPLASTY, 2002, 17 (01) : 90 - 94
  • [8] Knight J L, 1992, J Arthroplasty, V7 Suppl, P403, DOI 10.1016/S0883-5403(07)80031-3
  • [9] MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA
    LANDIS, JR
    KOCH, GG
    [J]. BIOMETRICS, 1977, 33 (01) : 159 - 174
  • [10] *MER TECHN LTD, ORTH