Two-stage biofilter for effective NH3 removal from waste gases containing high concentrations of H2S

被引:35
作者
Chung, Ying-Chien
Ho, Kuo-Ling
Tseng, Ching-Ping [1 ]
机构
[1] Natl Chiao Tung Univ, Dept Biol Sci & Technol, Hsinchu 300, Taiwan
[2] China Inst Technol, Dept Biol Sci & Technol, Taipei, Taiwan
关键词
D O I
10.1080/10473289.2007.10465332
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A high H2S concentration inhibits nitrification when H2S and NH3 are simultaneously treated'in a single biofilter. To improve NH3 removal from waste gases containing concentrated H2S, a two-stage biofilter was designed to solve the problem. In this study, the first biofilter, inoculated with Thiobacillus thioparus, was intended mainly to remove H2S and to reduce the effect of H2S concentration on nitrification in the second biofilter, and the second biofilter, inoculated with Nitrosomonas europaea, was to remove NH3. Extensive studies, which took into account the characteristics of gas removal, the engineering properties of the two biofilters, and biological parameters, were conducted in a 210-day operation. The results showed that an average 98% removal efficiency for H2S and a 100% removal efficiency for NH3 (empty bed retention time = 23-180 sec) were achieved after 70 days. The maximum degradation rate for NH3 was measured as 2.35 g N day(-1) kg of dry granular activated carbon'. Inhibition of nitrification was not found in the biofilter. This two-stage biofilter also exhibited good adaptability to shock loading and shutdown periods. Analysis of metabolic product and observation of the bacterial community revealed no obvious acidification or alkalinity phenomena. In addition, a lower moisture content (similar to 40%) for microbial survival and low pressure drop (average 24.39 mm H2O m(-1)) for system operation demonstrated that the two-stage biofilter was energy saving and economic. Thus, the two-stage biofilter is a feasible system to enhance NH3 removal in the concentrated coexistence of H2S.
引用
收藏
页码:337 / 347
页数:11
相关论文
共 41 条
[1]  
Barth Ed, 2002, Appl Occup Environ Hyg, V17, P10, DOI 10.1080/104732202753306078
[2]  
BEDARD C, 1989, MICROBIOL REV, V53, P68
[3]   Gas-phase removal of H2S and NH3 with dielectric barrier discharges [J].
Chang, MB ;
Tseng, TD .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1996, 122 (01) :41-46
[4]   Biodegradation of hydrogen sulfide by a laboratory-scale immobilized Pseudomonas putida CH11 biofilter [J].
Chung, YC ;
Huang, CP ;
Tseng, CP .
BIOTECHNOLOGY PROGRESS, 1996, 12 (06) :773-778
[5]   Biological elimination of H2S and NH3 from wastegases by biofilter packed with immobilized heterotrophic bacteria [J].
Chung, YC ;
Huang, CP ;
Tseng, CP .
CHEMOSPHERE, 2001, 43 (08) :1043-1050
[6]   Operation optimization of Thiobacillus thioparus CH11 biofilter for hydrogen sulfide removal [J].
Chung, YC ;
Huang, CP ;
Tseng, CP .
JOURNAL OF BIOTECHNOLOGY, 1996, 52 (01) :31-38
[7]   Biotreatment of ammonia in air by an immobilized Nitrosomonas europaea biofilter [J].
Chung, YC ;
Huang, CP .
ENVIRONMENTAL PROGRESS, 1998, 17 (02) :70-76
[8]   Control of H2S waste gas emissions with a biological activated carbon filter [J].
Chung, YC ;
Lin, YY ;
Tseng, CP .
JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2004, 79 (06) :570-577
[9]   Operational characteristics of effective removal of H2S and NH3 waste gases by activated carbon biofilter [J].
Chung, YC ;
Lin, YY ;
Tseng, CP .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2004, 54 (04) :450-458
[10]   Biotreatment of ammonia from air by an immobilized Arthrobacter oxydans CH8 biofilter [J].
Chung, YC ;
Huang, CP ;
Tseng, CP .
BIOTECHNOLOGY PROGRESS, 1997, 13 (06) :794-798