Wear Compliance and Activity in Children Wearing Wrist- and Hip-Mounted Accelerometers

被引:208
作者
Fairclough, Stuart J. [1 ,2 ]
Noonan, Robert [3 ]
Rowlands, Alex V. [4 ,5 ]
Van Hees, Vincent [6 ]
Knowles, Zoe [3 ]
Boddy, Lynne M.
机构
[1] Edge Hill Univ, Dept Sport & Phys Act, Ormskirk L39 4QP, Lancs, England
[2] Univ Limerick, Dept Phys Educ & Sport Sci, Limerick, Ireland
[3] Liverpool John Moores Univ, Res Inst Sport & Exercise Sci, Phys Act Exchange, Liverpool L3 5UX, Merseyside, England
[4] Univ Leicester, Leicester Gen Hosp, Diabet Res Ctr, Leicester, Leics, England
[5] Natl Inst Hlth Res, Leicester Loughborough Diet Lifestyle & Phys Act, Leicester, Leics, England
[6] Newcastle Univ, Inst Cellular Med, MoveLab, Phys Act & Exercise Res, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
关键词
RAW ACCELERATIONS; WEAR TIME; PHYSICAL ACTIVITY; GENEACTIV; ACTIGRAPH GT3X+; PHYSICAL-ACTIVITY MONITORS; RAW ACCELERATION; CALIBRATION; COMPARABILITY; OUTPUT;
D O I
10.1249/MSS.0000000000000771
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: This study aimed to 1) explore children's compliance to wearing wrist-and hip-mounted accelerometers, 2) compare children's physical activity (PA) derived from raw accelerations of wrist and hip, and 3) examine differences in raw and counts PA measured by hip-worn accelerometry. Methods: One hundred and twenty-nine 9- to 10-yr-old children wore a wrist-mounted GENEActiv accelerometer (GAwrist) and a hip-mounted ActiGraph GT3X+ accelerometer (AGhip) for 7 d. Both devices measured raw accelerations, and the AGhip also provided count-based data. Results: More children wore the GAwrist than those from the AGhip regardless of wear time criteria applied (P < 0.001-0.035). Raw data signal vector magnitude (r = 0.68), moderate PA (MPA) (r = 0.81), vigorous PA (VPA) (r = 0.85), and moderate-to-vigorous PA (MVPA) (r = 0.83) were strongly associated between devices (P < 0.001). GAwrist signal vector magnitude (P = 0.001), MPA (P = 0.037), VPA (P = 0.002), and MVPA (P = 0.016) were significantly greater than those from the AGhip. According to GAwrist raw data, 86.9% of children engaged in at least 60 min.d(-1) of MVPA, compared with 19% for AGhip. ActiGraph MPA (raw) was 42.00 +/- 1.61 min.d(-1) compared with 35.05 +/- 0.99 min.d(-1) (counts) (P = 0.02). ActiGraph VPA was 7.59 +/- 0.46 min.d(-1) (raw) and 37.06 +/- 1.85 min.d(-1) (counts; P = 0.19). Conclusions: In children, accelerometer wrist placement promotes superior compliance than the hip. Raw accelerations were significantly higher for GAwrist compared with those for AGhip possibly because of placement location and technical differences between devices. AGhip PA calculated from raw accelerations and counts differed substantially, demonstrating that PA outcomes derived from cut points for raw output and counts cannot be directly compared.
引用
收藏
页码:245 / 253
页数:9
相关论文
共 40 条
  • [21] Physical Activity Patterns Measured by Accelerometry in 6-to 10-yr-Old Children
    Nyberg, Gisela A.
    Nordenfelt, Anja M.
    Ekelund, Ulf
    Marcus, Claude
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2009, 41 (10) : 1842 - 1848
  • [22] Exploring the ActiLife® filtration algorithm: converting raw acceleration data to counts
    Peach, D.
    Van Hoomissen, J.
    Callender, H. L.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2014, 35 (12) : 2359 - 2367
  • [23] Calibration of the GENEA accelerometer for assessment of physical activity intensity in children
    Phillips, Lisa R. S.
    Parfitt, Gaynor
    Rowlands, Alex V.
    [J]. JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2013, 16 (02) : 124 - 128
  • [24] Validation and calibration of physical activity monitors in children
    Puyau, MR
    Adolph, AL
    Vohra, FA
    Butte, NF
    [J]. OBESITY RESEARCH, 2002, 10 (03): : 150 - 157
  • [25] Quality Control Methods in Accelerometer Data Processing: Defining Minimum Wear Time
    Rich, Carly
    Geraci, Marco
    Griffiths, Lucy
    Sera, Francesco
    Dezateux, Carol
    Cortina-Borja, Mario
    [J]. PLOS ONE, 2013, 8 (06):
  • [26] Estimating Activity and Sedentary Behavior from an Accelerometer on the Hip or Wrist
    Rosenberger, Mary E.
    Haskell, William L.
    Albinali, Fahd
    Mota, Selene
    Nawyn, Jason
    Intille, Stephen
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05) : 964 - 975
  • [27] Accelerometer counts and raw acceleration output in relation to mechanical loading
    Rowlands, A. V.
    Stiles, V. H.
    [J]. JOURNAL OF BIOMECHANICS, 2012, 45 (03) : 448 - 454
  • [28] Comparability of Measured Acceleration from Accelerometry-Based Activity Monitors
    Rowlands, Alex V.
    Fraysse, Francois
    Catt, Mike
    Stiles, Victoria H.
    Stanley, Rebecca M.
    Eston, Roger G.
    Olds, Tim S.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (01) : 201 - 210
  • [29] Children's Physical Activity Assessed with Wrist- and Hip-Worn Accelerometers
    Rowlands, Alex V.
    Rennie, Kirsten
    Kozarski, Robert
    Stanley, Rebecca M.
    Eston, Roger G.
    Parfitt, Gaynor C.
    Olds, Tim S.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (12) : 2308 - 2316
  • [30] Association Between Questionnaire- and Accelerometer-Assessed Physical Activity: The Role of Sociodemographic Factors
    Sabia, Severine
    van Hees, Vincent T.
    Shipley, Martin J.
    Trenell, Michael I.
    Hagger-Johnson, Gareth
    Elbaz, Alexis
    Kivimaki, Mika
    Singh-Manoux, Archana
    [J]. AMERICAN JOURNAL OF EPIDEMIOLOGY, 2014, 179 (06) : 781 - 790