Optimization of GATE and PHITS Monte Carlo code parameters for spot scanning proton beam based on simulation with FLUKA general-purpose code

被引:9
作者
Kurosu, Keita [1 ,2 ,3 ]
Das, Indra J. [1 ]
Moskvin, Vadim P. [1 ,4 ]
机构
[1] Indiana Univ Sch Med, Dept Radiat Oncol, Indianapolis, IN 46202 USA
[2] Osaka Univ, Grad Sch Med, Dept Radiat Oncol, 2-2 Yamadaoka, Suita, Osaka 5650871, Japan
[3] Osaka Univ Hosp, Dept Radiol, Suita, Osaka 5650871, Japan
[4] St Jude Childrens Res Hosp, Dept Radiat Oncol, 332 N Lauderdale St, Memphis, TN 38105 USA
关键词
Monte Carlo; GATE/Geant4; PHITS; FLUKA; Spot scanning proton beam; RADIATION-THERAPY; CLINICAL IMPLEMENTATION; 2ND CANCERS; RADIOTHERAPY; SYSTEM; PARTICLE; TOOLKIT; UNCERTAINTIES; VERIFICATION; SETTINGS;
D O I
10.1016/j.nimb.2015.11.017
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Spot scanning, owing to its superior dose-shaping capability, provides unsurpassed dose conformity, in particular for complex targets. However, the robustness of the delivered dose distribution and prescription has to be verified. Monte Carlo (MC) simulation has the potential to generate significant advantages for high-precise particle therapy, especially for medium containing inhomogeneities. However, the inherent choice of computational parameters in MC simulation codes of GATE, PHITS and FLUKA that is observed for uniform scanning proton beam needs to be evaluated. This means that the relationship between the effect of input parameters and the calculation results should be carefully scrutinized. The objective of this study was, therefore, to determine the optimal parameters for the spot scanning proton beam for both GATE and PHITS codes by using data from FLUKA simulation as a reference. The proton beam scanning system of the Indiana University Health Proton Therapy Center was modeled in FLUKA, and the geometry was subsequently and identically transferred to GATE and PHITS. Although the beam transport is managed by spot scanning system, the spot location is always set at the center of a water phantom of 600 x 600 x 300 mm(3), which is placed after the treatment nozzle. The percentage depth dose (PDD) is computed along the central axis using 0.5 x 0.5 x 0.5 mm(3) voxels in the water phantom. The PDD5 and the proton ranges obtained with several computational parameters are then compared to those of FLUKA, and optimal parameters are determined from the accuracy of the proton range, suppressed dose deviation, and computational time minimization. Our results indicate that the optimized parameters are different from those for uniform scanning, suggesting that the gold standard for setting computational parameters for any proton therapy application cannot be determined consistently since the impact of setting parameters depends on the proton irradiation technique. We therefore conclude that customization parameters must be set with reference to the optimized parameters of the corresponding irradiation technique in order to render them useful for achieving artifact-free MC simulation for use in computational experiments and clinical treatments. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:14 / 25
页数:12
相关论文
共 48 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   Experimental verification of IMPT treatment plans in an anthropomorphic phantom in the presence of delivery uncertainties [J].
Albertini, F. ;
Casiraghi, M. ;
Lorentini, S. ;
Rombi, B. ;
Lomax, A. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (14) :4415-4431
[3]   Geant4 developments and applications [J].
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Dubois, PA ;
Asai, M ;
Barrand, G ;
Capra, R ;
Chauvie, S ;
Chytracek, R ;
Cirrone, GAP ;
Cooperman, G ;
Cosmo, G ;
Cuttone, G ;
Daquino, GG ;
Donszelmann, M ;
Dressel, M ;
Folger, G ;
Foppiano, F ;
Generowicz, J ;
Grichine, V ;
Guatelli, S ;
Gumplinger, P ;
Heikkinen, A ;
Hrivnacova, I ;
Howard, A ;
Incerti, S ;
Ivanchenko, V ;
Johnson, T ;
Jones, F ;
Koi, T ;
Kokoulin, R ;
Kossov, M ;
Kurashige, H ;
Lara, V ;
Larsson, S ;
Lei, F ;
Link, O ;
Longo, F ;
Maire, M ;
Mantero, A ;
Mascialino, B ;
McLaren, I ;
Lorenzo, PM ;
Minamimoto, K ;
Murakami, K ;
Nieminen, P ;
Pandola, L ;
Parlati, S ;
Peralta, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) :270-278
[4]  
[Anonymous], 1973, ORNL4869
[5]   Dose conformation of intensity-modulated stereotactic photon beams, proton beams, and intensity-modulated proton beams for intracranial lesions [J].
Baumert, BG ;
Norton, IA ;
Lomax, AJ ;
Davis, JB .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (04) :1314-1324
[6]   The FLUKA Code: Developments and Challenges for High Energy and Medical Applications [J].
Boehlen, T. T. ;
Cerutti, F. ;
Chin, M. P. W. ;
Fosso, A. ;
Ferrari, A. ;
Ortega, P. G. ;
Mairani, A. ;
Sala, P. R. ;
Smirnov, G. ;
Vlachoudisl, V. .
NUCLEAR DATA SHEETS, 2014, 120 :211-214
[7]   Secondary neutrons in clinical proton radiotherapy: A charged issue [J].
Brenner, David J. ;
Hatt, Eric J. .
RADIOTHERAPY AND ONCOLOGY, 2008, 86 (02) :165-170
[8]   New Features of the INCL4 Model for Spallation Reactions [J].
Cugnon, J. ;
Mancusi, D. ;
Boudard, A. ;
Leray, S. .
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (02) :955-958
[9]  
Ferrari A., 2005, CERN200510, DOI [DOI 10.2172/877507, 10.5170/CERN-2005-010, DOI 10.5170/CERN-2005-010]
[10]  
GATE Radiation Therapy and Dosimetry working group, SETT PHYS PAR PROT T