In Vitro Evaluation of Fluorescence Glucose Biosensor Response

被引:27
作者
Aloraefy, Mamdouh [1 ,2 ]
Pfefer, T. Joshua [1 ]
Ramella-Roman, Jessica C. [3 ,4 ]
Sapsford, Kim E. [1 ]
机构
[1] US FDA, Ctr Devices & Radiol Hlth, Silver Spring, MD 20993 USA
[2] Catholic Univ Amer, Dept Biomed Engn, Washington, DC 20064 USA
[3] Florida Int Univ, Dept Biomed Engn, Miami, FL 33174 USA
[4] Florida Int Univ, Herbert Wertheim Coll Med, Miami, FL 33174 USA
来源
SENSORS | 2014年 / 14卷 / 07期
关键词
affinity biosensor; competitive binding; concanavalin A; continuous glucose monitoring; fluorescence sensor; FRET-based; glucose sensor; minimally-invasive; optical; MIDINFRARED LASER SPECTROSCOPY; COMPETITIVE-BINDING ASSAY; AFFINITY SENSOR; DIABETES MANAGEMENT; LINEAR-REGRESSION; ENERGY-TRANSFER; BLOOD-GLUCOSE; CONCANAVALIN; MICROSPHERES; PERFORMANCE;
D O I
10.3390/s140712127
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Rapid, accurate, and minimally-invasive glucose biosensors based on F rster Resonance Energy Transfer (FRET) for glucose measurement have the potential to enhance diabetes control. However, a standard set of in vitro approaches for evaluating optical glucose biosensor response under controlled conditions would facilitate technological innovation and clinical translation. Towards this end, we have identified key characteristics and response test methods, fabricated FRET-based glucose biosensors, and characterized biosensor performance using these test methods. The biosensors were based on competitive binding between dextran and glucose to concanavalin A and incorporated long-wavelength fluorescence dye pairs. Testing characteristics included spectral response, linearity, sensitivity, limit of detection, kinetic response, reversibility, stability, precision, and accuracy. The biosensor demonstrated a fluorescence change of 45% in the presence of 400 mg/dL glucose, a mean absolute relative difference of less than 11%, a limit of detection of 25 mg/dL, a response time of 15 min, and a decay in fluorescence intensity of 72% over 30 days. The battery of tests presented here for objective, quantitative in vitro evaluation of FRET glucose biosensors performance have the potential to form the basis of future consensus standards. By implementing these test methods for a long-visible-wavelength biosensor, we were able to demonstrate strengths and weaknesses with a new level of thoroughness and rigor.
引用
收藏
页码:12127 / 12148
页数:22
相关论文
共 61 条
  • [1] [Anonymous], DIABETES
  • [2] [Anonymous], 2006, 353412006 ISO
  • [3] [Anonymous], LIV DIAB
  • [4] Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring
    Aussedat, B
    Dupire-Angel, M
    Gifford, R
    Klein, JC
    Wilson, GS
    Reach, G
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2000, 278 (04): : E716 - E728
  • [5] Competitive-binding assay method based on fluorescence quenching of ligands held in close proximity by a multivalent receptor
    Ballerstadt, R
    Schultz, JS
    [J]. ANALYTICA CHIMICA ACTA, 1997, 345 (1-3) : 203 - 212
  • [6] In vitro long-term performance study of a near-infrared fluorescence affinity sensor for glucose monitoring
    Ballerstadt, R
    Polak, A
    Beuhler, A
    Frye, J
    [J]. BIOSENSORS & BIOELECTRONICS, 2004, 19 (08) : 905 - 914
  • [7] Ballerstadt R., 2014, BIOSENS BIO IN PRESS
  • [8] In vivo performance evaluation of a transdermal near-infrared fluorescence resonance energy transfer affinity sensor for continuous glucose monitoring
    Ballerstadt, Ralph
    Evans, Colton
    Gowda, Ashok
    McNichols, Roger
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2006, 8 (03) : 296 - 311
  • [9] Boren Suzanne Austin, 2010, J Diabetes Sci Technol, V4, P84
  • [10] Carstensen B., 2010, Comparing clinical measurement methods: a practical guide, V2nd ed.