Is it possible TO differentiate malignant mediastinal nodes from benign nodes by size? Reevaluation by CT, transesophageal echocardiography, and nodal specimen

被引:67
作者
Arita, T [1 ]
Matsumoto, T [1 ]
Kuramitsu, T [1 ]
Kawamura, M [1 ]
Matsunaga, N [1 ]
Sugi, K [1 ]
Esato, K [1 ]
机构
[1] YAMAGUCHI UNIV,SCH MED,DEPT SURG 1,UBE,YAMAGUCHI 755,JAPAN
关键词
computed tomography (CT) lung neoplasm; lymph node;
D O I
10.1378/chest.110.4.1004
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: To reevaluate whether it is possible to reliably differentiate malignant mediastinal lymph nodes from benign nodes by size, and to determine the frequency of metastases to normal-sized mediastinal lymph nodes that directly affects the sensitivity for detecting malignant mediastinal lymph nodes (N2 nodes) on CT. Design: Prospective study of patients with non-small cell lung cancer. Setting: Department of Radiology and First Department of Surgey, Yamaguchi University School of Medicine. Patients: We examined 40 patients with non-small cell lung cancer, who underwent thoracotomy because of operable stage (stage I, II, IIIA) in preoperative staging, using CT and transesophageal echocardiography (TEE). Interventions: None. Measurements and results: Lymph nodes 10 mm or greater in short-axis diameter on CT and TEE were considered abnormal. Furthermore, lymph node size was measured by TEE and nodal specimens in long- and short-axis diameter in each patient. Two hundred eight mediastinal lymph nodes mere dissected and N2 nodes were present in 28% of patients (11/40); in 7 of these 11 patients (64%), mediastinal lymph node metastases were misdiagnosed on CT because of normal-sized N2 nodes. Furthermore, in 73% of N2 nodes, nodal size was normal on TEE. There were no significant difference in both diameters between malignant mediastinal lymph nodes and benign nodes on TEE and nodal specimens. Conclusions: If is not possible to reliably differentiate malignant mediastinal nodes from benign nodes by size alone, and we should be aware of high frequency of normal-sized N2 nodes in patients with operable stage of lung cancer.
引用
收藏
页码:1004 / 1008
页数:5
相关论文
共 19 条
[1]   COMPUTED-TOMOGRAPHY IN THE PREOPERATIVE EVALUATION OF BRONCHOGENIC-CARCINOMA [J].
BARON, RL ;
LEVITT, RG ;
SAGEL, SS ;
WHITE, MJ ;
ROPER, CL ;
MARBARGER, JP .
RADIOLOGY, 1982, 145 (03) :727-732
[2]  
FALING LJ, 1981, AM REV RESPIR DIS, V124, P690
[3]   NORMAL MEDIASTINAL LYMPH-NODES - NUMBER AND SIZE ACCORDING TO AMERICAN-THORACIC-SOCIETY MAPPING [J].
GLAZER, GM ;
GROSS, BH ;
QUINT, LE ;
FRANCIS, IR ;
BOOKSTEIN, FL ;
ORRINGER, MB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 144 (02) :261-265
[4]   BRONCHOGENIC-CARCINOMA METASTATIC TO NORMAL-SIZED LYMPH-NODES - FREQUENCY AND SIGNIFICANCE [J].
GROSS, BH ;
GLAZER, GM ;
ORRINGER, MB ;
SPIZARNY, DL ;
FLINT, A .
RADIOLOGY, 1988, 166 (01) :71-74
[5]  
IMAMURA M, 1989, JPN J CHEST DIS, V48, P287
[6]  
JACOB H, 1990, EUR J CARDIO-THORAC, V4, P355
[7]  
*JAP LUNG CANC SOC, 1987, GEN RUL CLIN PATH RE, P79
[8]   PATHOLOGICAL ASSESSMENT OF MEDIASTINAL LYMPH-NODES IN LUNG-CANCER - IMPLICATIONS FOR NONINVASIVE MEDIASTINAL STAGING [J].
KERR, KM ;
LAMB, D ;
WATHEN, CG ;
WALKER, WS ;
DOUGLAS, NJ .
THORAX, 1992, 47 (05) :337-341
[9]   ROENTGENOGRAPHIC EVALUATION OF MEDIASTINAL NODES FOR PREOPERATIVE ASSESSMENT IN LUNG-CANCER [J].
MCKENNA, RJ ;
LIBSHITZ, HI ;
MOUNTAIN, CE ;
MCMURTREY, MJ .
CHEST, 1985, 88 (02) :206-210
[10]   BRONCHOGENIC-CARCINOMA - ANALYSIS OF STAGING IN THE MEDIASTINUM WITH CT BY CORRELATIVE LYMPH-NODE MAPPING AND SAMPLING [J].
MCLOUD, TC ;
BOURGOUIN, PM ;
GREENBERG, RW ;
KOSIUK, JP ;
TEMPLETON, PA ;
SHEPARD, JAO ;
MOORE, EH ;
WAIN, JC ;
MATHISEN, DJ ;
GRILLO, HC .
RADIOLOGY, 1992, 182 (02) :319-323