Three-dimensional magnetic resonance pelvimetry: A new technique for evaluating the female pelvis in pregnancy

被引:16
作者
Liao, K. D. [1 ]
Yu, Y. H. [1 ]
Li, Y. G. [1 ]
Chen, L. [1 ]
Peng, C. [1 ]
Liu, P. [1 ]
Chen, C. L. [1 ]
Chen, R. Y. [2 ]
Zhong, M. [1 ]
Wang, Y. [1 ]
机构
[1] Southern Med Univ, NanFang Hosp, Dept Obstet & Gynecol, Guangzhou, Guangdong, Peoples R China
[2] Southern Med Univ, NanFang Hosp, Dept Radiol, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
MR imaging; Pelvimetry; Three-dimensional reconstruction; Term; Pregnancy; X-RAY PELVIMETRY; COMPUTED-TOMOGRAPHY; RACIAL-DIFFERENCES; CHILDHOOD-CANCER; DISPROPORTION; INDEX; WOMEN;
D O I
10.1016/j.ejrad.2018.03.024
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To describe three-dimensional (3D) magnetic resonance imaging (MRI) pelvimetry methods and to establish the pelvimetric reference in a large population of Chinese females at term pregnancy. Methods: Three-hundred one pregnant women at term who underwent MRI were included. Three-dimensional pelvic models were reconstructed using Mimics. 10.0 software based on MRI data sets, and measurements of these models were made. Pelvimetric results according to delivery modality were presented. Additionally, the previously described CT 3D pelvimetry method for predicting cephalopelvic disproportion (CPD) was used to validate its accuracy. Results: Two hundred ten women underwent vaginal delivery, and 13 underwent caesarean delivery for CPD. 3D modelling of the pelvis of pregnant women was feasible using MR data sets. Pelvimetric parameters in the vaginal delivery group were as follows: transverse diameter, 134.7 mm +/- 7.5; obstetric conjugate, 126.9 mm +/- 8.3; interspinous distance, 113.4 mm +/- 8.2; sagittal midpelvis, 117.8 mm +/- 8.1; intertuberous distance, 127.1 mm +/- 10.4; sagittal outlet, 110.2 mm +/- 8.9, and posterior sagittal outlet, 59.7 mm +/- 8.1. According to the previously described CT 3D pelvimetry method for predicting CPD, 67.6% (142/210) of women in the vaginal delivery group were diagnosed with CPD. Conclusion: 3D MR pelvimetry is a novel method for determining pelvic dimensions at term pregnancy. A prospective trial is needed to establish a useful value for predicting CPD in Chinese females at high risk of CPD.
引用
收藏
页码:208 / 212
页数:5
相关论文
共 50 条
[41]   Reconstruction of three-dimensional models for complex female pelvic tumors [J].
Liu, Yingwei ;
Meng, Shenglan ;
Wei, Miao ;
Dai, Fengqin ;
Xiao, Lin ;
Mu, Xiaoling ;
Tang, Junying .
INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2022, 157 (03) :747-749
[42]   Novel Three-Dimensional Body Scan Anthropometry versus MR-Pelvimetry for Vaginal Breech Delivery Assessment [J].
Dathan-Stumpf, Anne ;
Lia, Massimiliano ;
Meigen, Christof ;
Bornmann, Karoline ;
Martin, Mireille ;
Assmann, Manuela ;
Kiess, Wieland ;
Stepan, Holger .
JOURNAL OF CLINICAL MEDICINE, 2023, 12 (19)
[43]   Three-dimensional analysis of regional left ventricular endocardial curvature from cardiac magnetic resonance images [J].
Maffessanti, Francesco ;
Lang, Roberto M. ;
Niel, Johannes ;
Steringer-Mascherbauer, Regina ;
Caiani, Enrico G. ;
Nesser, Hans-Joachim ;
Mor-Avi, Victor .
MAGNETIC RESONANCE IMAGING, 2011, 29 (04) :516-524
[44]   Evaluation of the contours and perianeurysmal environment of unruptured cerebral aneurysms, using three-dimensional magnetic resonance cisternogram [J].
Satoh, T ;
Ekino, C ;
Ohsako, C ;
Katsumata, A ;
Onoda, K ;
Tsuchimoto, S ;
Yunoki, M ;
Tokunaga, K ;
Sugiu, K ;
Date, I .
NEUROLOGICAL SURGERY, 2004, 32 (03) :215-221
[45]   Double uterus associated with renal aplasia; magnetic resonance appearance and three-dimensional computed tomographic urogram [J].
Imai, A ;
Takagi, H ;
Matsunami, K .
INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2004, 87 (02) :169-171
[46]   Motion-based microwave tomographic measurement device for three-dimensional coverage in a magnetic resonance system [J].
Meaney, Paul M. ;
Raynolds, Timothy ;
Geimer, Shireen D. ;
Ouma, David ;
Player, Grace M. ;
Yang, Xiaoyu ;
Paulsen, Keith D. .
MEDICAL PHYSICS, 2022, 49 (12) :7638-7647
[47]   Three-dimensional ultrashort echo time magnetic resonance imaging in pediatric patients with pneumonia: a comparative study [J].
Sun, Yan ;
Chen, Yujie ;
Li, Xuesheng ;
Liao, Yi ;
Chen, Xijian ;
Song, Yu ;
Liang, Xinyue ;
Dai, Yongming ;
Chen, Dapeng ;
Ning, Gang .
BMC MEDICAL IMAGING, 2023, 23 (01)
[48]   Three-dimensional reconstruction of subject-specific knee joint using computed tomography and magnetic resonance imaging image data fusions [J].
Dong, Yuefu ;
Mou, Zhifang ;
Huang, Zhenyu ;
Hu, Guanghong ;
Dong, Yinghai ;
Xu, Qingrong .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (10) :1083-1093
[49]   Three-dimensional reconstruction using an adaptive simultaneous algebraic reconstruction technique in electron tomography [J].
Wan, Xiaohua ;
Zhang, Fa ;
Chu, Qi ;
Zhang, Kai ;
Sun, Fei ;
Yuan, Bo ;
Liu, Zhiyong .
JOURNAL OF STRUCTURAL BIOLOGY, 2011, 175 (03) :277-287
[50]   Computer Application of Ultrasound and Nuclear Magnetic Resonance Images for the Anatomical Learning of the Pelvis and the Female Pelvic Floor [J].
Asensio Romero, Lourdes ;
Asensio Gomez, Manuel ;
Prats-Galino, Alberto ;
Juanes Mendez, Juan Antonio .
JOURNAL OF MEDICAL SYSTEMS, 2019, 43 (05)