Transmission system parameters optimization - Sensitivity analysis of secondary arc current and recovery voltage

被引:16
作者
Tavares, MC [1 ]
Portela, CM
机构
[1] Univ Estadual Campinas, BR-13073970 Campinas, SP, Brazil
[2] Univ Fed Rio de Janeiro, Rio De Janeiro, Brazil
基金
巴西圣保罗研究基金会;
关键词
EMTP; optimization; recovery voltage; secondary arc current; single-phase auto-reclosing (SPAR); transient analysis; transmission system;
D O I
10.1109/TPWRD.2004.829158
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper shows the importance of optimizing the transmission system parameters from its conception, considering the relevant options and possibilities, in order to have a better cost-performance result. The presented results were obtained in the study of a real transmission system expansion, based on a 865-km long line. The single-phase auto-reclosing (SPAR) procedure was one of the aspects carefully studied, in order to assure adequate transmission reliability. The secondary arc current was mitigated through the traditional solution of using the neutral reactor on the existing shunt reactor banks, which permitted the reduction of the secondary arc current to acceptable values, assuring natural arc extinction and successful SPAR. The method of obtaining the optimized value for the neutral reactor and its implications on the system performance are important aspects, and are discussed in this paper.
引用
收藏
页码:1464 / 1471
页数:8
相关论文
共 28 条
[1]   SINGLE-PHASE TRIPPING AND AUTO RECLOSING OF TRANSMISSION-LINES IEEE COMMITTEE REPORT [J].
ESZTERGALYOS, J ;
ANDRICHAK, J ;
COLWELL, DH ;
DAWSON, DC ;
JODICE, JA ;
MURRAY, TJ ;
MUSTAPHI, KK ;
NAIL, GR ;
POLITIS, A ;
POPE, JW ;
ROCKEFELLER, GD ;
STRANNE, GP ;
TZIOUVARAS, D ;
SCHWEITZER, EO .
IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (01) :182-192
[2]   SINGLE-PHASE SWITCHING TESTS ON THE AEP 765 KV SYSTEM - EXTINCTION TIME FOR LARGE SECONDARY ARC CURRENTS [J].
FAKHERI, AJ ;
SHUTER, TC ;
SCHNEIDER, JM ;
SHIH, CH .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (08) :2775-2783
[3]   FORCED EXTINCTION CHARACTERISTICS OF SECONDARY ARC ON UHV (1000KV CLASS) TRANSMISSION-LINES [J].
GODA, Y ;
MATSUDA, S ;
INABA, T ;
OZAKI, Y ;
MOUSA, AM .
IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (03) :1322-1330
[4]  
GOLDBERG S, 1989, IEEE T POWER DELIVER, V4, P586
[5]   THE APPLICATION OF HIGH-SPEED GROUNDING SWITCHES FOR SINGLE-POLE RECLOSING ON 500 KV POWER-SYSTEMS [J].
HASIBAR, RM ;
LEGATE, AC ;
BRUNKE, J ;
PETERSON, WG .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (04) :1512-1515
[6]  
Kimbark E. W., 1964, IEEE Trans, V83, P285
[7]   SELECTIVE-POLE SWITCHING OF LONG DOUBLE-CIRCUIT EHV LINE [J].
KIMBARK, EW .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (01) :219-230
[8]  
KIZILCAY M, 1994, EUR T ELECTR POW, V4, P177
[9]  
NAGEL TJ, 1980, IEEE SPECTRUM SEP, P14
[10]  
PEIXOTO C, 1984, P INT C DC POW TRANS, P127