Degradation evaluation of crystalline-silicon photovoltaic modules after a few operation years in a tropical environment

被引:127
作者
Ndiaye, Ababacar [1 ]
Kebe, Cheikh M. F. [1 ]
Charki, Abderafi [2 ]
Ndiaye, Papa A. [1 ]
Sambou, Vincent [1 ]
Kobi, Abdessamad [2 ]
机构
[1] Ecole Super Polytech UCAD, Ctr Int Format & Rech Energie Solaire, Dakar, Senegal
[2] Univ Angers ISTIA LASQUO, F-49000 Angers, France
关键词
Photovoltaic module; Degradation; Tropical environment; AMORPHOUS-SILICON; PV MODULES; PERFORMANCE; ENERGY; METHODOLOGY;
D O I
10.1016/j.solener.2014.02.006
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents an evaluation of the performance degradation of Photovoltaic modules after few operation years in a tropical environment. To this end, the International Center for Research and Training in solar energy at Dakar University and the Lasquo-ISTIA laboratory of Angers University have put in place a research project in order to investigate the impact of the tropical climatic conditions on the PV modules characteristics. Accordingly, two monocrystalline-silicon (mc-Si) PV modules and two polycrystalline- silicon (pc-Si) PV modules are installed at Dakar in Senegal and monitored during a few operation years: Module A (16 months), Module B (41 months), Module C (48 months) and Module D (48 months). After few operation years under tropical environment, the global degradation and the degradation rate of electrical characteristics such as I-V and P-V curves, open-circuit voltage (V-oc), short-circuit current (I-sc), maximum ouput current (I-max), maximum output voltage (V-max), maximum power output (P-max) and fill factor (FF) are evaluate at standard test conditions (STC). This study reports on data collected from 4 distinct mono- and poly-crystalline modules deployed at Dakar University in Senegal. The study has shown that P-max, I-max, I-sc and FF are the most degraded performance characteristics for all PV modules. The maximum power output (P-max) presents the highest loss that can be from 0.22%/year to 2.96%/year. However, the open-circuit voltage (V-oc) is not degraded after these few exposition years for all studied PV modules. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:70 / 77
页数:8
相关论文
共 32 条
[1]   Performance and reliability of a 1-kW amorphous silicon photovoltaic roofing system [J].
Adelstein, J ;
Sekulic, B .
CONFERENCE RECORD OF THE THIRTY-FIRST IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE - 2005, 2005, :1627-1630
[2]  
[Anonymous], 2012, 4 400 DATASHEET
[3]  
[Anonymous], 2012, DATASHEET 1 5 400
[4]   bhoots Methodology to Size an Optimal Stand-Alone PV/wind/diesel/battery System Minimizing the Levelized cost of Energy and the CO2 Emissions [J].
Bilal, B. Ould ;
Sambou, V. ;
Kebe, C. M. F. ;
Ndiaye, P. A. ;
Ndongo, M. .
2011 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY ENGINEERING (ICAEE), 2012, 14 :1636-1647
[5]   A comparison of the performance of different PV module types in temperate climates [J].
Carr, AJ ;
Pryor, TL .
SOLAR ENERGY, 2004, 76 (1-3) :285-294
[6]  
Cereghetti N, 2003, WORL CON PHOTOVOLT E, P1919
[7]  
Chamberlin C.E., 2011, IEEE PV SPEC C SEATT
[8]   The Time-Variant Degradation of a Photovoltaic System [J].
Charki, A. ;
Laronde, R. ;
Bigaud, D. .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (02)
[9]   The performance of crystalline silicon photovoltaic solar modules after 22 years of continuous outdoor exposure [J].
Dunlop, ED ;
Halton, D .
PROGRESS IN PHOTOVOLTAICS, 2006, 14 (01) :53-64
[10]  
Granata J.E., 2009, 2009 34th IEEE Photovolt. Spec. Conf, P001486, DOI [DOI 10.1109/PVSC.2009.5411336, 10.1109/PVSC.2009.5411336]