Measurement of the uterocervical angle for the prediction of preterm birth in symptomatic women

被引:9
作者
Wagner, Philipp [1 ]
Schlechtendahl, Jana [1 ]
Hoopmann, Markus [1 ]
Prodan, Natalia [1 ]
Abele, Harald [1 ]
Kagan, Karl Oliver [1 ]
机构
[1] Univ Tubingen, Dept Obstet & Gynaecol, Calwerstr 7, D-72076 Tubingen, Germany
关键词
Preterm birth; Cervical length; Preterm labor; Uterocervical angle;
D O I
10.1007/s00404-021-06002-0
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Purpose To examine if the uterocervical angle (UCA) can be used to predict preterm delivery in women with painful and regular uterine contractions and a cervical length of 25 mm or less. Methods Retrospective study at the perinatal unit of the University Hospital of Tuebingen, Germany. Women with singleton gestation and preterm contractions between 24 + 0 and 33 + 6 weeks' gestation were included. For the UCA measurement, a line is placed from the internal os to the external os irrespective of whether the cervix is straight or curved. A second line is drawn to delineate the lower uterine segment. The angle between the two lines is the UCA measurement. The measurements were taken on stored images from our database. Results The study consisted of 213 singleton pregnancies. At the time of UCA measurement, median maternal and gestational age was 31.4 years and 29.7 weeks' gestation. Median gestational age at delivery was 35.3 weeks and the corresponding birth weight 2480 g, respectively. The UCA measurement in women who delivered within 2 days, between 3-7 days and after 7 days was not helpful to distinguish between these three groups [median UCA measurements: 108.5 degrees, 108.0 degrees and 107.3 degrees (Kruskal-Wallis test p = 0.576)]. Uni- and multivariate logistic multiple regression analysis demonstrated that the delivery within 2 days was only dependent on the gestational age and the cervical length at the time of presentation. Conclusion The measurement of UCA is not useful in predicting preterm birth in the subsequent 7 days after an episode of preterm contractions.
引用
收藏
页码:663 / 669
页数:7
相关论文
共 27 条
[1]   Targeted therapy for threatened preterm labor based on sonographic measurement of the cervical length: a randomized controlled trial [J].
Alfirevic, Z. ;
Allen-Coward, H. ;
Molina, F. ;
Vinuesa, C. P. ;
Nicolaides, K. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2007, 29 (01) :47-50
[2]   Beyond Cervical Length: Association between Postcerclage Transvaginal Ultrasound Parameters and Preterm Birth [J].
Battarbee, Ashley N. ;
Ellis, Joshua S. ;
Manuck, Tracy A. .
AMERICAN JOURNAL OF PERINATOLOGY, 2019, 36 (13) :1317-1324
[3]   Cervical length screening for prevention of preterm birth in singleton pregnancy with threatened preterm labor: systematic review and meta-analysis of randomized controlled trials using individual patient-level data [J].
Berghella, V. ;
Palacio, M. ;
Ness, A. ;
Alfirevic, Z. ;
Nicolaides, K. H. ;
Saccone, G. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2017, 49 (03) :322-U34
[4]   Cervical assessment by ultrasound for preventing preterm delivery [J].
Berghella, Vincenzo ;
Saccone, Gabriele .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2019, (09)
[5]   Preterm birth prevention [J].
da Fonseca, Eduardo B. ;
Damiao, Rievani ;
Moreira, Daniela Aires .
BEST PRACTICE & RESEARCH CLINICAL OBSTETRICS & GYNAECOLOGY, 2020, 69 :40-49
[6]   Assessment of Uterocervical Angle Width as a Predictive Factor of Preterm Birth: A Systematic Review of the Literature [J].
Daskalakis, George ;
Theodora, Marianna ;
Antsaklis, Panagiotis ;
Sindos, Michael ;
Grigoriadis, Themistoklis ;
Antsaklis, Aris ;
Papantoniou, Nikolaos ;
Loutradis, Dimitrios ;
Pergialiotis, Vasilios .
BIOMED RESEARCH INTERNATIONAL, 2018, 2018
[7]   Uterocervical angle: a novel ultrasound screening tool to predict spontaneous preterm birth [J].
Dziadosz, Margaret ;
Bennett, Terri-Ann ;
Dolin, Cara ;
Honart, Anne West ;
Pham, Amelie ;
Lee, Sarah S. ;
Pivo, Sarah ;
Roman, Ashley S. .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2016, 215 (03)
[8]   The prevalence and clinical significance of amniotic fluid 'sludge' in patients with preterm labor and intact membranes [J].
Espinoza, J ;
Gonçalves, LF ;
Romero, R ;
Nien, JK ;
Stites, S ;
Kim, YM ;
Hassan, S ;
Gomez, R ;
Yoon, BH ;
Chaiworapongsa, T ;
Lee, W ;
Mazor, M .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2005, 25 (04) :346-352
[9]   A soft cervix, categorized by shear-wave elastography, in women with short or with normal cervical length at 18-24 weeks is associated with a higher prevalence of spontaneous preterm delivery [J].
Hernandez-Andrade, Edgar ;
Maymon, Eli ;
Luewan, Suchaya ;
Bhatti, Gaurav ;
Mehrmohammadi, Mohammad ;
Erez, Offer ;
Pacora, Percy ;
Done, Bogdan ;
Hassan, Sonia S. ;
Romero, Roberto .
JOURNAL OF PERINATAL MEDICINE, 2018, 46 (05) :489-501
[10]   Screening to prevent spontaneous preterm birth: systematic reviews of accuracy and effectiveness literature with economic modelling [J].
Honest, H. ;
Forbes, C. A. ;
Duree, K. H. ;
Norman, G. ;
Duffy, S. B. ;
Tsourapas, A. ;
Roberts, T. E. ;
Barton, P. M. ;
Jowett, S. M. ;
Hyde, C. J. ;
Khan, K. S. .
HEALTH TECHNOLOGY ASSESSMENT, 2009, 13 (43) :1-+