Peripheral venous pressure predicts central venous pressure poorly in pediatric patients

被引:0
作者
Leipoldt, Carl C. P.
McKay, William P. S.
Clunie, Michelle
Miller, Grant
机构
[1] Univ Saskatchewan, Dept Anesthesia, Saskatoon, SK, Canada
[2] Univ Saskatchewan, Dept Surg, Saskatoon, SK, Canada
来源
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE | 2006年 / 53卷 / 12期
关键词
D O I
10.1007/BF03021582
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Purpose: Using peripheral venous pressure (PVP) instead of central venous pressure (CVP) as a volume monitor decreases patient risks and costs, and is convenient. This study was undertaken to determine if PVP predicts CVP in pediatric patients. Methods: With ethical approval and informed consent, 30 pediatric patients aged neonate to 12 yr requiring a central venous line were studied prospectively in a tertiary care teaching hospital. In the supine position, PVP and CVP were simultaneously transduced. Ninety-six paired recordings of CVP and PVP were made. Correlation and Bland-Altman analysis of agreement of end-expiratory measurements were performed. Results: The mean (SD; range) CVP was 10.0 mmHg (6.0; - 1.0 to 27.0); the mean PVP was 13.7 mmHg (6.3; 0.0 to 33.0); offset (bias) of PVP > CVP was 3.7 mmHg with SD 2.6. The 95% confidence intervals (CI) for the bias were 3.2 to 4.1 mmHg. In the Bland-Altman analysis, lower and upper limits of agreement (LOA; Cl in parentheses) were - 1.5 (-2.3 to -0.7) and 8.8 (8.1 to 9.6) mmHg. Eight of 96 points were outside the limits of agreement. The correlation of PVP on CVP was r = 0.92, P < 0.0001. For a subset of ten patients (20 simultaneous recordings) with iv catheters proximal to the hand, limits of agreement were better - offset: 3.8 mmHg (+/- 1.4); lower LOA: 1.2 mmHg (0.25 to 2.1); upper LOA: 6.6 mmHg (5.7 to 7.5). Conclusion: Peripheral venous pressure measured from an iv catheter in the hand predicts CVP poorly in pediatric patients.
引用
收藏
页码:1207 / 1212
页数:6
相关论文
共 14 条
[1]   Correlation of peripheral venous pressure and central venous pressure in surgical patients [J].
Amar, D ;
Melendez, JA ;
Zhang, H ;
Dobres, C ;
Leung, DHY ;
Padilla, RE .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2001, 15 (01) :40-43
[2]   Peripheral venous pressure is an alternative to central venous pressure in paediatric surgery patients [J].
Anter, AM ;
Bondok, RS .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2004, 48 (09) :1101-1104
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Can peripheral venous pressure be interchangeable with central venous pressure in patients undergoing cardiac surgery? [J].
Desjardins, R ;
Denault, AY ;
Bélisle, S ;
Carrier, M ;
Babin, D ;
Lévesque, S ;
Martineau, R .
INTENSIVE CARE MEDICINE, 2004, 30 (04) :627-632
[5]   Injuries and liability related to central vascular catheters - A closed claims analysis [J].
Domino, KB ;
Bowdle, TA ;
Posner, KL ;
Spitellie, PH ;
Lee, LA ;
Cheney, FW .
ANESTHESIOLOGY, 2004, 100 (06) :1411-1418
[6]   DIRECT BLOOD-PRESSURE MEASUREMENT - DYNAMIC-RESPONSE REQUIREMENTS [J].
GARDNER, RM .
ANESTHESIOLOGY, 1981, 54 (03) :227-236
[7]   Correlation of peripheral venous pressure and central venous pressure in kidney recipients [J].
Hadimioglu, N ;
Ertug, Z ;
Yegin, A ;
Sanli, S ;
Gurkan, A ;
Demirbas, A .
TRANSPLANTATION PROCEEDINGS, 2006, 38 (02) :440-442
[8]   A PROPOSAL FOR SCIENTIFIC VALIDATION OF INSTRUMENTS FOR INDIRECT BLOOD-PRESSURE MEASUREMENT AT REST, DURING EXERCISE, AND IN CRITICAL CARE [J].
IYRIBOZ, Y ;
HEARON, CM .
JOURNAL OF CLINICAL MONITORING, 1994, 10 (03) :163-177
[9]   Equivalence of fast flush and square wave testing of blood pressure monitoring systems [J].
Kleinman, B ;
Powell, S ;
Gardner, RM .
JOURNAL OF CLINICAL MONITORING, 1996, 12 (02) :149-154
[10]  
MARK JB, 2000, ANESTHESIA, P1134