Acoustic biosensors

被引:64
作者
Fogel, Ronen [1 ]
Limson, Janice [1 ]
Seshia, Ashwin A. [2 ]
机构
[1] Rhodes Univ, Biotechnol Innovat Ctr, POB 94, ZA-6140 Grahamstown, South Africa
[2] Univ Cambridge, Dept Engn, Cambridge CB2 1PZ, England
来源
BIOSENSOR TECHNOLOGIES FOR DETECTION OF BIOMOLECULES | 2016年 / 60卷 / 01期
关键词
QUARTZ-CRYSTAL MICROBALANCE; FUNDAMENTAL FILM PARAMETERS; QCM-D; SURFACE MODIFICATION; WAVE BIOSENSORS; CROSS-LINKING; DISSIPATION; PROTEIN; ADSORPTION; MICROCHANNEL;
D O I
10.1042/EBC20150011
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Resonant and acoustic wave devices have been researched for several decades for application in the gravimetric sensing of a variety of biological and chemical analytes. These devices operate by coupling the measurand (e. g. analyte adsorption) as a modulation in the physical properties of the acoustic wave (e. g. resonant frequency, acoustic velocity, dissipation) that can then be correlated with the amount of adsorbed analyte. These devices can also be miniaturized with advantages in terms of cost, size and scalability, as well as potential additional features including integration with microfluidics and electronics, scaled sensitivities associated with smaller dimensions and higher operational frequencies, the ability to multiplex detection across arrays of hundreds of devices embedded in a single chip, increased throughput and the ability to interrogate a wider range of modes including within the same device. Additionally, device fabrication is often compatible with semiconductor volume batch manufacturing techniques enabling cost scalability and a high degree of precision and reproducibility in the manufacturing process. Integration with microfluidics handling also enables suitable sample pre-processing/separation/purification/amplification steps that could improve selectivity and the overall signal-to-noise ratio. Three device types are reviewed here: (i) bulk acoustic wave sensors, (ii) surface acoustic wave sensors, and (iii) micro/nanoelectromechanical system (MEMS/NEMS) sensors.
引用
收藏
页码:101 / 110
页数:10
相关论文
共 57 条
[1]   An embedded microchannel in a MEMS plate resonator for ultrasensitive mass sensing in liquid [J].
Agache, V. ;
Blanco-Gomez, G. ;
Baleras, F. ;
Caillat, P. .
LAB ON A CHIP, 2011, 11 (15) :2598-2603
[2]  
[Anonymous], 1997, Acoustic Wave Sensors: Theory, Design, and Physics-Chemical Applications
[3]   Quartz crystal microbalance with dissipation and microscale thermophoresis as tools for investigation of protein complex formation between thymidylate synthesis cycle enzymes [J].
Antosiewicz, Anna ;
Senkara, Elzbieta ;
Ciesla, Joanna .
BIOSENSORS & BIOELECTRONICS, 2015, 64 :36-42
[4]   Comparative advantages of mechanical biosensors [J].
Arlett, J. L. ;
Myers, E. B. ;
Roukes, M. L. .
NATURE NANOTECHNOLOGY, 2011, 6 (04) :203-215
[5]   Covalent bound sensing layers on surface acoustic wave (SAW) biosensors [J].
Barié, N ;
Rapp, M .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) :979-987
[6]  
Braun T, 2009, NAT NANOTECHNOL, V4, P179, DOI [10.1038/nnano.2008.398, 10.1038/NNANO.2008.398]
[7]   Weighing of biomolecules, single cells and single nanoparticles in fluid [J].
Burg, Thomas P. ;
Godin, Michel ;
Knudsen, Scott M. ;
Shen, Wenjiang ;
Carlson, Greg ;
Foster, John S. ;
Babcock, Ken ;
Manalis, Scott R. .
NATURE, 2007, 446 (7139) :1066-1069
[8]   Suspended microchannel resonators for biomolecular detection [J].
Burg, TP ;
Manalis, SR .
APPLIED PHYSICS LETTERS, 2003, 83 (13) :2698-2700
[9]   Acoustic quantification of ATP using a quartz crystal microbalance with dissipation [J].
Cengiz Oezalp, Veli .
ANALYST, 2011, 136 (23) :5046-5050
[10]   Structured thin films as functional components within biosensors [J].
Davis, F ;
Higson, SPJ .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (01) :1-20