Determination of ammonium and organic bound nitrogen by inductively coupled plasma emission spectroscopy

被引:15
作者
Jaber, A. M. Y. [1 ]
Mehanna, N. A. [2 ]
Sultan, S. M. [1 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Chem, Dhahran 31261, Saudi Arabia
[2] Ind Support Serv Labs, Dammam 31463, Saudi Arabia
关键词
Inductively coupled plasma; Hydride generation; Kjeldahl method; KJELDAHL NITROGEN; AQUEOUS-SOLUTION; EXTENDED TORCH; SAMPLES;
D O I
10.1016/j.talanta.2009.01.060
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The continuous flow sample introduction technique with a hydride generator system in conjunction with an inductively coupled plasma emission spectrometer (ICP-AES-HG), is used in this study for quantitative determination of ammonium and organic bound nitrogen in aqueous and solid samples. Ammonia vapor released from ammonium salt after treatment with concentrated NaOH is transferred by argon to plasma for detection at 174.273 nm using axial argon plasma mode. The calibration curves were linear within a range of 25-1000 mg L-1 N as ammonium molybdate with correlation coefficients of better than 0,99 and limits of detection of about 10-25 ring L-1 N. The percent recovery of N (25-500 mg L-1 N) in soft (distilled) water and high salt content (1.7 mol L-1 NaCl) matrices was found to be in the range of about 97-102% with %RSD in the range of 4.6-0.62. The sensitivity, limit of detection, and blank contribution from the atmospheric nitrogen, were tremendously improved in this method compared with the available ICP-AES spray chamber counterpart. Furthermore, the ICP-AES-HG method gave results for real samples (soil, fertilizer, waste water) containing about 50-1800 mg L-1 N in good agreement with those obtained by the standard Kjeldahl method. No statistical differences at the 95% confidence level on applying the t-test were observed between the values obtained by the two methods. Thus, the ICP-AES-HG method is reliable and faster than the conventional tedious Kjeldahl method, superior to the ICP-AES spray chamber method, and almost free from matrix interference which is usually a critical factor in atomic emission spectroscopic techniques. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1298 / 1302
页数:5
相关论文
共 25 条
[1]   DETERMINATION OF TRACES OF AMMONIUM-NITROGEN IN AQUEOUS-SOLUTION BY OPTICAL EMISSION SPECTROMETRY WITH A HIGH-FREQUENCY INDUCTIVELY COUPLED ARGON PLASMA SOURCE [J].
ALDER, JF ;
GUNN, AM ;
KIRKBRIGHT, GF .
ANALYTICA CHIMICA ACTA, 1977, 92 (01) :43-48
[2]  
*AOAC, 1990, OFFICIAL METHODS ANA, V1, P17
[3]  
*AWWA APHA, 1998, STAND METH EX WAT WA
[4]  
Boss C.B., 1997, Concept, Instrumentation and Techniques in Inductively Coupled Plasma Optical Emission Spectrometry, V2nd
[5]  
BOTTOM G, 1987, J AOAC, V70, P227
[6]   SOME EXPERIMENTS WITH AN EXTENDED TORCH FOR THE DETERMINATION OF NITROGEN IN AQUEOUS-SOLUTION WITH THE AID OF ICP-AES [J].
BROEKAERT, JAC ;
ZEEMAN, PB .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1984, 39 (06) :851-853
[7]   Total dissolved nitrogen analysis: comparisons between the persulfate, UV and high temperature oxidation methods [J].
Bronk, DA ;
Lomas, MW ;
Glibert, PM ;
Schukert, KJ ;
Sanderson, MP .
MARINE CHEMISTRY, 2000, 69 (1-2) :163-178
[8]   A microscale Kjeldahl nitrogen determination for environmental waters [J].
Campins-Falco, P. ;
Meseguer-Lloret, S. ;
Climent-Santamaria, T. ;
Molins-Legua, C. .
TALANTA, 2008, 75 (04) :1123-1126
[9]  
CERDA A, 2000, HDB WATER ANAL, P261
[10]  
CHRISTIAN GD, 1994, ANAL CHEM, P240