Flow-modulated comprehensive two-dimensional gas chromatography combined with time-of-flight mass spectrometry: use of hydrogen as a more sustainable alternative to helium

被引:16
作者
Galletta, Micaela [1 ]
Zoccali, Mariosimone [2 ]
Jones, Nick [3 ]
Mondello, Luigi [1 ,4 ,5 ]
Tranchida, Peter Q. [1 ]
机构
[1] Univ Messina, Dept Chem Biol Pharmaceut & Environm Sci, Messina, Italy
[2] Univ Messina, Dept Math & Comp Sci Phys Sci & Earth Sci, Messina, Italy
[3] LECO European Applicat & Technol Ctr EATC, Berlin, Germany
[4] Univ Messina, Dept Chem Biol Pharmaceut & Environm Sci, Chromaleont SRL, Messina, Italy
[5] Univ Campus Biomed Rome, Dept Sci & Technol Human & Environm, Rome, Italy
关键词
Comprehensive two-dimensional gas chromatography; Flow modulation; Time-of-flight mass spectrometry; CARRIER;
D O I
10.1007/s00216-022-04086-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The present research is focused on the use and evaluation of hydrogen, as a more sustainable alternative to helium, within the context of fast flow modulation comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry. In such a respect, a comparison was made between the two mobile phases in terms of speed and overall chromatography performance. All experiments were carried out by using the following column set: low polarity with dimensions 10 m x 0.25 mm ID x 0.25 mu m d(f) and medium polarity with dimensions 2 m x 0.10 mm ID x 0.10 mu m d(f). Fundamental gas chromatography parameters (efficiency, resolution) were measured under different experimental conditions, using the two carrier gases. Efficiency was measured in both the first and second dimensions, using a probe compound under isothermal conditions; after defining the optimum carrier gas conditions, a mixture containing 20 pesticides was analyzed to measure resolution, again in the first and second dimensions, using a temperature program. It was found (as expected) that a similar chromatography performance could be attained when using hydrogen, albeit with a circa 25% reduction in analysis time. Signal-to-noise ratios of the pesticides were calculated, using both carrier gases, with such values generally reduced (on average by 14%) when using hydrogen. Finally, a comparison was made between mass spectral profiles obtained analyzing the pesticides and fatty acid methyl esters using the two mobile phases. Even though mass spectral differences were observed, the ion profiles could be considered generally similar.
引用
收藏
页码:6371 / 6378
页数:8
相关论文
共 10 条
[1]   PRELIMINARY OBSERVATIONS ON THE USE OF A NOVEL LOW DUTY CYCLE FLOW MODULATOR FOR COMPREHENSIVE TWO-DIMENSIONAL GAS CHROMATOGRAPHY [J].
Aloisi, Ivan ;
Giocastro, Barbara ;
Ferracane, Antonio ;
Salerno, Tania M. G. ;
Zoccali, Mariosimone ;
Tranchida, Peter Q. ;
Mondello, Luigi .
JOURNAL OF CHROMATOGRAPHY A, 2021, 1643
[2]   Flow regime at ambient outlet pressure and its influence in comprehensive two-dimensional gas chromatography [J].
Beens, J ;
Janssen, HG ;
Adahchour, M ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1086 (1-2) :141-150
[3]   Comparison of one-dimensional and comprehensive two-dimensional separations by gas chromatography [J].
Blumberg, Leonid M. ;
David, Frank ;
Klee, Matthew S. ;
Sandra, Pat .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1188 (01) :2-16
[4]   Possibilities and limitations of fast GC with narrow-bore columns [J].
Domotorova, Milena ;
Kirchner, Michal ;
Matisova, Eva ;
de Zeeuw, Jaap .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (08) :1051-1063
[5]  
Ettre L.S., 1993, BASIC RELATIONSHIPS
[6]  
Gaines RB, 1998, J MICROCOLUMN SEP, V10, P597
[7]   COMPREHENSIVE 2-DIMENSIONAL GAS-CHROMATOGRAPHY USING AN ON-COLUMN THERMAL MODULATOR INTERFACE [J].
LIU, ZY ;
PHILLIPS, JB .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (06) :227-231
[8]   Use of hydrogen as a carrier gas for the analysis of steroids with anabolic activity by gas chromatography-mass spectrometry [J].
Munoz-Guerra, J. A. ;
Prado, P. ;
Garcia-Tenorio, S. Vargas .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (41) :7365-7370
[9]   Hydrogen as a GC/MS carrier and buffer gas for use in forensic laboratories [J].
Nnaji, Chinyere N. ;
Williams, Kristina C. ;
Bishop, Jonathan M. ;
Verbeck, Guido F. .
SCIENCE & JUSTICE, 2015, 55 (03) :162-167
[10]   The multi-mode modulator: A versatile fluidic device for two-dimensional gas chromatography [J].
Seeley, John V. ;
Schimmel, Nicolaas E. ;
Seeley, Stacy K. .
JOURNAL OF CHROMATOGRAPHY A, 2018, 1536 :6-15