High-resolution X-ray and neutron computed tomography of partially saturated granular materials subjected to projectile penetration

被引:19
|
作者
Kim, Felix Hoyean [1 ]
Penumadu, Dayakar [1 ]
Kardjilov, Nikolay [2 ]
Manke, Ingo [2 ]
机构
[1] Univ Tennessee, Dept Civil & Environm Engn, 851 Neyland Dr,325 John D Tickle Bldg, Knoxville, TN 37996 USA
[2] Helmholtz Ctr Berlin Mat & Energy, Hahn Meitner Pl 1, D-14109 Berlin, Germany
关键词
Partially saturated sand; Projectile penetration; Neutron; X-ray; Computed tomography; IMPACT RESPONSE; STRAIN; SAND; BEHAVIOR;
D O I
10.1016/j.ijimpeng.2015.11.008
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
To improve fundamental understandings of projectile penetration through partially saturated sand at a meso-scale and provide controlled experimental data to validate future numerical simulations, high resolution computed tomography of granular materials after projectile penetration using two different imaging modalities (X-rays and neutrons) was implemented. This paper presents the novel imaging techniques and results of studying the variation of geometric structure (arrangement of solids, voids, liquid films) at a meso-scale after the penetration of projectiles (ex-situ) under controlled conditions. Attenuation contrast obtained from X-rays and neutrons provided complementary information that would not have been possible to obtain by using X-rays only. X-rays identified silica particles and their boundaries at 14.8 mu m/pixel resolution, while neutrons spatially resolved small amounts of moisture at 15.6 mu m/pixel resolution due to a large neutron cross-section of hydrogen. Lead (Pb) contained in most projectile tips is opaque to X-rays but transparent to neutrons at the energy range generally used for imaging. Indeed, the need for using multi-modal imaging is further emphasized for non-invasive damage diagnostics. Partially saturated crystalline sand specimens with bulk gravimetric water contents of 5 similar to 6% were studied at two different initial packing states (dense and loose) using two different types of commercially available projectiles. A novel image registration technique combined 3-D attenuation data obtained at different spatial resolution with two imaging modalities (X-ray and neutron). The role of moisture in sand on penetration resistance and related effects on the meso-structure has not been studied in detail in the past, and the results from the current study show important preliminary insights on this topic. The effects of projectile impact and penetration on particle rearrangements, fractures, and water re-distributions are summarized as a function of the initial specimen state of compaction and projectile parameters (mass, impact velocity, twist during penetration, and with use of full metal jacket ammunition). Observations of damage patterns including penetration depth and cavity formation are summarized in this paper, and the findings form an important basis for an improved understanding of penetration mechanics in porous materials and related multiscale modeling framework. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:72 / 82
页数:11
相关论文
共 50 条
  • [31] In Situ X-ray Tomography and 3D X-ray Diffraction Measurements of Cemented Granular Materials
    Zhai, C.
    Pagan, D. C.
    Hurley, R. C.
    JOM, 2020, 72 (01) : 18 - 27
  • [32] A review of X-ray computed tomography of concrete and asphalt construction materials
    du Plessis, Anton
    Boshoff, William P.
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 199 : 637 - 651
  • [33] High-resolution x-ray CT screening of mutant mouse models
    Paulus, MJ
    Gleason, SS
    Sari-Sarraf, H
    Johnson, DK
    Foltz, CJ
    Austin, DW
    Easterly, ME
    Michaud, EJ
    Dhar, MS
    Hunsicker, PR
    Wall, JW
    Schell, M
    OPTICAL DIAGNOSTICS OF LIVING CELLS III, 2000, 3921 : 270 - 279
  • [34] X-ray high-resolution vascular network imaging
    Plouraboué, F
    Cloetens, P
    Fonta, C
    Steyer, A
    Lauwers, F
    Marc-Vergnes, JP
    JOURNAL OF MICROSCOPY-OXFORD, 2004, 215 : 139 - 148
  • [35] High-resolution imaging silicon X-ray spectrometers
    Strüder, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 522 (1-2) : 146 - 146
  • [36] Investigation of the effect of specific interfacial area on strength of unsaturated granular materials by X-ray tomography
    Wang, Ji-Peng
    Lambert, Pierre
    De Kock, Tim
    Cnudde, Veerle
    Francois, Bertrand
    ACTA GEOTECHNICA, 2019, 14 (05) : 1545 - 1559
  • [37] Cranial anatomy of the spade-headed amphisbaenian Diplometopon zarudnyi (Squamata, Amphisbaenia) based on high-resolution X-ray computed tomography
    Maisano, JA
    Kearney, M
    Rowe, T
    JOURNAL OF MORPHOLOGY, 2006, 267 (01) : 70 - 102
  • [38] Assessing the effect of penetration length variations on dimensional measurements with X-ray computed tomography
    Villarraga-Gomez, Herminso
    Morse, Edward P.
    Smith, Stuart T.
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2023, 79 : 146 - 163
  • [39] Investigation of pile penetration in calcareous soft rock using X-ray computed tomography
    Alvarez-Borges, Fernando
    Ahmed, Sharif
    Madhusudhan, Bangalore Narasimha
    Richards, David
    INTERNATIONAL JOURNAL OF PHYSICAL MODELLING IN GEOTECHNICS, 2022, 22 (01) : 38 - 52
  • [40] Computed tomography for light materials using a monochromatic X-ray beam produced by parametric X-ray radiation
    Hayakawa, Y.
    Hayakawa, K.
    Inagaki, M.
    Kaneda, T.
    Nakao, K.
    Nogami, K.
    Sakae, T.
    Sakai, T.
    Sato, I.
    Takahashi, Y.
    Tanaka, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 309 : 230 - 236