High-resolution X-ray and neutron computed tomography of partially saturated granular materials subjected to projectile penetration

被引:19
|
作者
Kim, Felix Hoyean [1 ]
Penumadu, Dayakar [1 ]
Kardjilov, Nikolay [2 ]
Manke, Ingo [2 ]
机构
[1] Univ Tennessee, Dept Civil & Environm Engn, 851 Neyland Dr,325 John D Tickle Bldg, Knoxville, TN 37996 USA
[2] Helmholtz Ctr Berlin Mat & Energy, Hahn Meitner Pl 1, D-14109 Berlin, Germany
关键词
Partially saturated sand; Projectile penetration; Neutron; X-ray; Computed tomography; IMPACT RESPONSE; STRAIN; SAND; BEHAVIOR;
D O I
10.1016/j.ijimpeng.2015.11.008
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
To improve fundamental understandings of projectile penetration through partially saturated sand at a meso-scale and provide controlled experimental data to validate future numerical simulations, high resolution computed tomography of granular materials after projectile penetration using two different imaging modalities (X-rays and neutrons) was implemented. This paper presents the novel imaging techniques and results of studying the variation of geometric structure (arrangement of solids, voids, liquid films) at a meso-scale after the penetration of projectiles (ex-situ) under controlled conditions. Attenuation contrast obtained from X-rays and neutrons provided complementary information that would not have been possible to obtain by using X-rays only. X-rays identified silica particles and their boundaries at 14.8 mu m/pixel resolution, while neutrons spatially resolved small amounts of moisture at 15.6 mu m/pixel resolution due to a large neutron cross-section of hydrogen. Lead (Pb) contained in most projectile tips is opaque to X-rays but transparent to neutrons at the energy range generally used for imaging. Indeed, the need for using multi-modal imaging is further emphasized for non-invasive damage diagnostics. Partially saturated crystalline sand specimens with bulk gravimetric water contents of 5 similar to 6% were studied at two different initial packing states (dense and loose) using two different types of commercially available projectiles. A novel image registration technique combined 3-D attenuation data obtained at different spatial resolution with two imaging modalities (X-ray and neutron). The role of moisture in sand on penetration resistance and related effects on the meso-structure has not been studied in detail in the past, and the results from the current study show important preliminary insights on this topic. The effects of projectile impact and penetration on particle rearrangements, fractures, and water re-distributions are summarized as a function of the initial specimen state of compaction and projectile parameters (mass, impact velocity, twist during penetration, and with use of full metal jacket ammunition). Observations of damage patterns including penetration depth and cavity formation are summarized in this paper, and the findings form an important basis for an improved understanding of penetration mechanics in porous materials and related multiscale modeling framework. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:72 / 82
页数:11
相关论文
共 50 条
  • [21] Experimental Study of High-Temperature Fracture Propagation in Anthracite and Destruction of Mudstone from Coalfield Using High-Resolution Microfocus X-ray Computed Tomography
    Xiao, Yang
    Lu, Jun-Hui
    Wang, Cai-Ping
    Deng, Jun
    ROCK MECHANICS AND ROCK ENGINEERING, 2016, 49 (09) : 3723 - 3734
  • [22] Capillary Suction Measurements in Granular Materials and Direct Numerical Simulations Using X-Ray Computed Tomography Microstructure
    Thakur, Mohmad Mohsin
    Penumadu, Dayakar
    Bauer, Constantin
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2020, 146 (01)
  • [23] Laboratory x-ray fluorescence tomography for high-resolution nanoparticle bio-imaging
    Hertz, Hans M.
    Larsson, Jakob C.
    Lundstrom, Ulf
    Larsson, Daniel H.
    Vogt, Carmen
    OPTICS LETTERS, 2014, 39 (09) : 2790 - 2793
  • [24] A simulation study of high-resolution x-ray computed tomography imaging using irregular sampling with a photon-counting detector
    Lee, Seungwan
    Choi, Yu-Na
    Kim, Hee-Joung
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 726 : 175 - 180
  • [25] Validation of a high-resolution X-ray computed tomography system to measure murine adipose tissue depot mass in situ and longitudinally
    Hildebrandt, AL
    Kelly-Sullivan, DM
    Black, SC
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2002, 47 (02) : 99 - 106
  • [26] APPLICATION OF HIGH RESOLUTION TRANSMISSION X-RAY TOMOGRAPHY IN MATERIAL SCIENCE
    Wang Shaogang
    Wang Sucheng
    Zhang Lei
    ACTA METALLURGICA SINICA, 2013, 49 (08) : 897 - 910
  • [27] High resolution X-ray computed tomography: An emerging tool for small animal cancer research
    Paulus, MJ
    Gleason, SS
    Kennel, SJ
    Hunsicker, PR
    Johnson, DK
    NEOPLASIA, 2000, 2 (1-2): : 62 - 70
  • [28] Quantifying foraminiferal growth with high-resolution X-ray computed tomography: New opportunities in foraminiferal ontogeny, phylogeny, and paleoceanographic applications
    Speijer, Robert P.
    Van Loo, Denis
    Masschaele, Bert
    Vlassenbroeck, Jelle
    Cnudde, Veerle
    Jacobs, Patric
    GEOSPHERE, 2008, 4 (04): : 760 - 763
  • [29] Taguchi Orthogonal Test on Granule Properties and Porosity Distribution in Sintering Bed using High-resolution X-ray Computed Tomography
    Xu, Jianuo
    Zhou, Hao
    Zhou, Mingxi
    Hu, Shihao
    Zuo, Yuhang
    ISIJ INTERNATIONAL, 2020, 60 (06) : 1149 - 1158
  • [30] The characterization of x-ray polycapillary optics with a high-resolution x-ray optical bench
    Jach, T
    Steel, E
    ChenMayer, H
    Ullrich, J
    Downing, RG
    Thurgate, S
    MULTILAYER AND GRAZING INCIDENCE X-RAY/EUV OPTICS III, 1996, 2805 : 192 - 201