Fourier transform spectrometer for spectral emissivity measurement in the temperature range between 60 and 1500°C

被引:43
作者
Dai, Jingmin [1 ]
Wang, Xinbei [1 ]
Yuan, Guibin [1 ]
机构
[1] Harbin Inst Technol, POB 308, Harbin 150001, Peoples R China
来源
7th International Symposium on Measurement Technology and Intelligent Instruments | 2005年 / 13卷
关键词
D O I
10.1088/1742-6596/13/1/015
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A new spectral emissivity measurement system has been developed at Harbin Institute of Technology (HIT) by using a Fourier transform infrared (FTIR) spectrometer. The spectral range between 0.6 and 25 mu m was covered by a photovoltaic HgCdTe and a silicon photodiode detector. A SiC heater with a black hole was employed for heating the sample. The temperature of the sample can be controlled in a range between 60 and 1500 degrees C with an error of less than 1 degrees C. The system was calibrated against two high quality reference blackbodies: a low temperature heat-pipe blackbody operated in the temperature range between 60 degrees C and 300 degrees C and a high temperature blackbody with SiC heater operated in the temperature range between 300 degrees C and 1500 degrees C. Several tests were done for this new system. The estimated uncertainty of emissivity measurement is better than 3%.
引用
收藏
页码:63 / 66
页数:4
相关论文
共 10 条
[1]   Measurement of surface temperature and emissivity by a multitemperature method for Fourier-transform infrared spectrometers [J].
Clausen, S ;
Morgenstjerne, A ;
Rathmann, O .
APPLIED OPTICS, 1996, 35 (28) :5683-5691
[2]  
DAI JM, 2004, 7 INT WORKSH SUBS TH
[3]  
FISCHER J, 1999, P TEMPMEKO 99, P27
[4]   Effective emissivities of black-body cavities with grooved cylinders [J].
Ishii, J ;
Kobayashi, M ;
Sakuma, F .
METROLOGIA, 1998, 35 (03) :175-180
[5]   Uncertainty estimation for emissivity measurements near room temperature with a Fourier transform spectrometer [J].
Ishii, J ;
Ono, A .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (12) :2103-2112
[6]   Portable Fourier transform infrared spectroradiometer for field measurements of radiance and emissivity [J].
Korb, AR ;
Dybwad, P ;
Wadsworth, W ;
Salisbury, JW .
APPLIED OPTICS, 1996, 35 (10) :1679-1692
[7]  
LINDERMEIR E, 1992, PROC SPIE, V1682, P354, DOI 10.1117/12.58553
[8]  
ONO A, 1999, P TEMPMEKO 99, P487
[9]   RADIOMETRIC CALIBRATION OF IR FOURIER-TRANSFORM SPECTROMETERS - SOLUTION TO A PROBLEM WITH THE HIGH-RESOLUTION INTERFEROMETER SOUNDER [J].
REVERCOMB, HE ;
BUIJS, H ;
HOWELL, HB ;
LAPORTE, DD ;
SMITH, WL ;
SROMOVSKY, LA .
APPLIED OPTICS, 1988, 27 (15) :3210-3218
[10]  
WANG X, 2003, BEIJING LIGONG DAXUE, V23, P405