Survey of protein-based sport supplements for illegally added anabolic steroids methyltestosterone and 4-androstenedione by UPLC-MS/MS

被引:15
作者
Alaedini, Somaye [1 ]
Amirahmadi, Maryam [2 ,3 ]
Kobarfard, Farzad [4 ]
Rastegar, Hossein [2 ,3 ]
Nasirahmadi, Sasan [3 ]
Shoeibi, Shahram [2 ,3 ]
机构
[1] Islamic Azad Univ, Pharmaceut Sci Branch, Tehran, Iran
[2] Minist Hlth MOH, Food & Drug Org FDO, Food & Drug Labs Res Ctr FDLRC, POB 11136-15911,408,Imam Khomeini Ave, Tehran, Iran
[3] Minist Hlth MOH, Food & Drug Org FDO, Food & Drug Control Labs References Ctr FDLCRC, Tehran, Iran
[4] Shahid Beheshti Univ Med Sci, Sch Pharm, Dept Med Chem, Tehran, Iran
关键词
4-Androstenedione; Anabolic hormones; UPLC-MS/MS; Methyltestosterone; Sport supplements; TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; NUTRITIONAL SUPPLEMENTS; ELECTROSPRAY-IONIZATION; DIETARY-SUPPLEMENTS; GC-MS; QUANTIFICATION; DERIVATIZATION; TESTOSTERONE; CONFIRMATION;
D O I
10.1016/j.steroids.2020.108758
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
There is some evidence that marketable supplements contain hormones not declared on the product label. The presence of these androgenic anabolic steroids (AAS) in sports supplements can be considered an adulteration and affect the health of consumers, who are predominantly athletes. This study aimed to measure anabolic hormones (methyltestosterone and 4-androstenedione) in sport supplements. Ultra Performance Liquid chromatography coupled mass spectrometry (UPLC-MS/MS) with electrospray ionization (ESI) in positive mode was employed under the Multiple Reaction Monitoring (MRM) ion program. To overcome matrix effects and quantify the selected analyte, the calibration curve was made using Matrix Match method. The LOQ and LOD were 1 ng/g and 0.3 ng/g for both analytes. The recovery of 4-androstenedione and methyltestosterone was in the range of 86.87-107.35 and 77.31-113.98, respectively. In terms of reproducibility, CV % for 4-androstenedione and methyltestosterone ranged from 6.56 to 16.87% and 1.45-15.12%, respectively. 4-androstenedione was found in 11 samples including 9 whey as 1.578 +/- 0.154 ng/g and 2 whey albumin samples with an amount of 1.134 ng/g and 1.474 ng/g. Consequently, continuous controlling of sport supplements comprising intentionally or unintentionally added androgens could be important for health and discuss in the context of compliance with anti-doping.
引用
收藏
页数:8
相关论文
共 36 条
[1]   Abuse of anabolic androgenic steroids and related substances in sport and exercise [J].
Bahrke, MS ;
Yesalis, CE .
CURRENT OPINION IN PHARMACOLOGY, 2004, 4 (06) :614-620
[2]  
Barreiro R, 2015, FOODS, V4, P605, DOI 10.3390/foods4040605
[3]   Toxicity and carcinogenicity of androstenedione in F344/N rats and B6C3F1 mice [J].
Blystone, Chad R. ;
Elmore, Susan A. ;
Witt, Kristine L. ;
Malarkey, David E. ;
Foster, Paul M. D. .
FOOD AND CHEMICAL TOXICOLOGY, 2011, 49 (09) :2116-2124
[4]  
Brass EP, 2000, AM J CLIN NUTR, V72, p618S, DOI 10.1093/ajcn/72.2.618S
[5]   International Society of Sports Nutrition position stand: creatine supplementation and exercise [J].
Buford, Thomas W. ;
Kreider, Richard B. ;
Stout, Jeffrey R. ;
Greenwood, Mike ;
Campbell, Bill ;
Spano, Marie ;
Ziegenfuss, Tim ;
Lopez, Hector ;
Landis, Jamie ;
Antonio, Jose .
JOURNAL OF THE INTERNATIONAL SOCIETY OF SPORTS NUTRITION, 2007, 4
[6]   Comparison of various international guidelines for analytical method validation [J].
Chandran, S. ;
Singh, R. S. P. .
PHARMAZIE, 2007, 62 (01) :4-14
[7]   Creatine supplementation with specific view to exercise/sports performance: an update [J].
Cooper, Robert ;
Naclerio, Fernando ;
Allgrove, Judith ;
Jimenez, Alfonso .
JOURNAL OF THE INTERNATIONAL SOCIETY OF SPORTS NUTRITION, 2012, 9
[8]   Validation of multi-residue methods for the detection of anabolic steroids by GC-MS in muscle tissues and urine samples from cattle [J].
Daeseleire, E ;
Vandeputte, R ;
Van Peteghem, C .
ANALYST, 1998, 123 (12) :2595-2598
[9]   Quantitative confirmation of testosterone and epitestosterone in human urine by LC/Q-ToF mass spectrometry for doping control [J].
Danaceau, Jonathan P. ;
Morrison, M. Scott ;
Slawson, Matthew H. .
JOURNAL OF MASS SPECTROMETRY, 2008, 43 (07) :993-1000
[10]   Detection and determination of anabolic steroids in nutritional supplements [J].
De Cock, KJS ;
Delbeke, FT ;
Van Eenoo, P ;
Desmet, N ;
Roels, K ;
De Backer, P .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 25 (5-6) :843-852