Endoscopic ultrasound-guided biliary drainage using a newly designed metal stent with a thin delivery system: a preclinical study in phantom and porcine models

被引:10
作者
Minaga, Kosuke [1 ]
Kitano, Masayuki [2 ]
Itonaga, Masahiro [2 ]
Imai, Hajime [1 ]
Miyata, Takeshi [1 ]
Yamao, Kentaro [1 ]
Tamura, Takashi [2 ]
Nuta, Junya [2 ]
Warigaya, Kenji [3 ]
Kudo, Masatoshi [1 ]
机构
[1] Kindai Univ, Fac Med, Dept Gastroenterol & Hepatol, Osaka, Japan
[2] Wakayama Med Univ, Dept Internal Med 2, 811-1 Kimiidera, Wakayama 6418509, Japan
[3] Wakayama Med Univ, Dept Human Pathol, Wakayama, Japan
基金
日本学术振兴会;
关键词
Endoscopic ultrasound; EUS-guided biliary drainage; EUS-BD; EUS-guided choledochoduodenostomy; Stent; MIGRATION; HEPATICOGASTROSTOMY; MULTICENTER; COMPLICATIONS; FEASIBILITY; OBSTRUCTION; CAVITY;
D O I
10.1007/s10396-017-0850-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was designed to evaluate the feasibility and safety of a newly designed self-expandable metal stent for endoscopic ultrasound-guided biliary drainage (EUS-BD) when it was delivered via three different stent delivery systems: a 7.5Fr delivery catheter with a bullet-shaped tip (7.5Fr-bullet), a 7Fr catheter with a bullet-shaped tip (7Fr-bullet), or a 7Fr catheter with a tee-shaped tip (7Fr-tee). This experimental study utilized a porcine model of biliary dilatation involving ten pigs. In the animal study, technical feasibility and clinical outcomes of the stent when placed with each of the delivery systems were examined. In addition, a phantom model was used to measure the resistance of these delivery systems to advancement. Phantom experiments showed that, compared with 7Fr-bullet, 7Fr-tee had less resistance force to the advancement of the stent delivery system. EUS-BD was technically successful in all ten pigs. Fistulous tract dilation was necessary in 100% (2/2), 75% (3/4), and 0% (0/4) of the pigs that underwent EUS-BD using 7.5Fr-bullet, 7Fr-bullet, and 7Fr-tee, respectively. There were no procedure-related complications. Our newly designed metal stent may be feasible and safe for EUS-BD, particularly when delivered by 7Fr-tee, because it eliminates the need for fistulous tract dilation.
引用
收藏
页码:391 / 397
页数:7
相关论文
共 22 条
  • [1] Endoscopic ultrasound-guided bilioduodenal anastomosis: A new technique for biliary drainage
    Giovannini, M
    Moutardier, V
    Pesenti, C
    Bories, E
    Lelong, B
    Delpero, JR
    [J]. ENDOSCOPY, 2001, 33 (10) : 898 - 900
  • [2] Endoscopic ultrasonography-guided biliary drainage: Who, when, which, and how?
    Hara, Kazuo
    Yamao, Kenji
    Mizuno, Nobumasa
    Hijioka, Susumu
    Imaoka, Hiroshi
    Tajika, Masahiro
    Tanaka, Tutomu
    Ishihara, Makoto
    Okuno, Nozomi
    Hieda, Nobuhiro
    Yoshida, Tukasa
    Niwa, Yasumasa
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2016, 22 (03) : 1297 - 1303
  • [3] Clinical evaluation of a novel lumen-apposing metal stent for endosonography-guided pancreatic pseudocyst and gallbladder drainage (with videos)
    Itoi, Takao
    Binmoeller, Kenneth F.
    Shah, Janak
    Sofuni, Atsushi
    Itokawa, Fumihide
    Kurihara, Toshio
    Tsuchiya, Takayoshi
    Ishii, Kentaro
    Tsuji, Shujiro
    Ikeuchi, Nobuhito
    Moriyasu, Fuminori
    [J]. GASTROINTESTINAL ENDOSCOPY, 2012, 75 (04) : 870 - 876
  • [4] Stent selection and tips on placement technique of EUS-guided biliary drainage: transduodenal and transgastric stenting
    Itoi, Takao
    Isayama, Hiroyuki
    Sofuni, Atsushi
    Itokawa, Fumihide
    Kurihara, Toshio
    Tsuchiya, Takayoshi
    Tsuji, Shujiro
    Ishii, Kentaro
    Ikeuchi, Nobuhito
    Tanaka, Reina
    Umeda, Junko
    Moriyasu, Fuminori
    Kawakami, Hiroshi
    [J]. JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2011, 18 (05) : 664 - 672
  • [5] Multicenter retrospective study of endoscopic ultrasound-guided biliary drainage for malignant biliary obstruction in Japan
    Kawakubo, Kazumichi
    Isayama, Hiroyuki
    Kato, Hironari
    Itoi, Takao
    Kawakami, Hiroshi
    Hanada, Keiji
    Ishiwatari, Hirotoshi
    Yasuda, Ichiro
    Kawamoto, Hirofumi
    Itokawa, Fumihide
    Kuwatani, Masaki
    Iiboshi, Tomohiro
    Hayashi, Tsuyoshi
    Doi, Shinpei
    Nakai, Yousuke
    [J]. JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2014, 21 (05) : 328 - 334
  • [6] Endoscopic Ultrasound-Guided Biliary Drainage: A Systematic Review and Meta-Analysis
    Khan, Muhammad Ali
    Akbar, Ali
    Baron, Todd H.
    Khan, Sobia
    Kocak, Mehmat
    Alastal, Yaseen
    Hammad, Tariq
    Lee, Wade M.
    Sofi, Aijaz
    Artifon, Everson L. A.
    Nawras, Ali
    Ismail, Mohammad Kashif
    [J]. DIGESTIVE DISEASES AND SCIENCES, 2016, 61 (03) : 684 - 703
  • [7] EUS-guided choledochoduodenostomy for malignant distal biliary obstruction using a lumen-apposing fully covered metal stent after failed ERCP
    Kunda, Rastislav
    Perez-Miranda, Manuel
    Will, Uwe
    Ullrich, Sebastian
    Brenke, Dirk
    Dollhopf, Markus
    Meier, Michelle
    Larghi, Alberto
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2016, 30 (11): : 5002 - 5008
  • [8] Complications of diagnostic and therapeutic Endoscopic Ultrasound
    Lakhtakia, Sundeep
    [J]. BEST PRACTICE & RESEARCH CLINICAL GASTROENTEROLOGY, 2016, 30 (05) : 807 - 823
  • [9] A Novel, Fully Covered Laser-Cut Nitinol Stent with Antimigration Properties for Nonresectable Distal Malignant Biliary Obstruction: A Multicenter Feasibility Study
    Lsayama, Hiroyuki
    Kawakubo, Kazumichi
    Nakai, Yousuke
    Inoue, Kouta
    Gon, Chimyon
    Matsubara, Saburo
    Kogure, Hirofumi
    Ito, Yukiko
    Tsujino, Takeshi
    Mizuno, Suguru
    Hamada, Tsuyoshi
    Uchino, Rie
    Miyabayashi, Koji
    Yamamoto, Keisuke
    Sasaki, Takashi
    Yamamoto, Natsuyo
    Hirano, Kenji
    Sasahira, Naoki
    Tada, Minoru
    Koike, Kazuhiko
    [J]. GUT AND LIVER, 2013, 7 (06) : 725 - 730
  • [10] Migration of a covered metallic stent following endoscopic ultrasound-guided hepaticogastrostomy: fatal complication
    Martins, F. P.
    Rossini, L. G. B.
    Ferrari, A. P.
    [J]. ENDOSCOPY, 2010, 42 : E126 - E127