Comparing pre-therapeutic 124I and 131I uptake tests with intra-therapeutic 131I uptake in benign thyroid disorders

被引:3
作者
Guhne, Falk [1 ]
Kuhnel, Christian [1 ]
Freesmeyer, Martin [1 ]
机构
[1] Jena Univ Hosp, Clin Nucl Med, Jena, Germany
关键词
(124)Iodine; PET/CT; RAIU; Uptake; Benign thyroid disorders; ACTIVITY I-124-PET/LOW-DOSE CT; RADIOIODINE THERAPY; PROCEDURE GUIDELINE; IODIDE TRANSPORT; DOSIMETRY PRIOR; STANDARD; HYPERTHYROIDISM; TOMOGRAPHY; KINETICS; VALUES;
D O I
10.1007/s12020-017-1267-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
I-124-PET/CT can be used for pre-therapeutic assessment of radioactive iodine uptake in benign thyroid disorders, however systematic comparisons with intra-therapeutic uptake are still lacking for these disorders. The goals of this study were to compare I-124 RAIU and conventional I-131 RAIU tests with each other; to compare both tests with intra-therapeutic uptake (reference); and to verify the time course of radioactive iodine uptake at three time points (30, 102, and 336 h [14 days] post administration; p.a.). Thirteen patients with benign thyroid diseases underwent I-131 RAIU test and I-124 RAIU test one after another before the intra-therapeutic I-131 uptake (reference) was measured via short-range and long-range measurements. After correction for decay, relative uptake differences were calculated and subjected to the Bland-Altman method for the evaluation of levels of agreement. Radioactive iodine uptake tests with I-124-PET/CT and I-131 probe did not show systematic deviations at any time point. Likewise, at 30 and 102 h p.a. there was no systematic discrepancy between pre-therapeutic and intra-therapeutic uptake levels. At 14 days p.a., however, both pre-therapeutic tests tended to overestimate the uptake compared to reference. Findings showed, for the first time with I-124, that radioiodine therapy has some early radiobiological effects possibly limiting the accuracy of pre-therapeutic dosimetry. I-124 RAIU tests represent a feasible alternative to standard I-131 RAIU tests. The additional benefits of I-124-PET/CT (e.g., functional topography, inclusion of retrosternal areas, possibility to enable fusion imaging) may thus increase the scope of this technology in benign thyroid disorders.
引用
收藏
页码:43 / 53
页数:11
相关论文
共 40 条
[11]   Clinical applications of 124I-PET/CT in patients with differentiated thyroid cancer [J].
Freudenberg, Lutz S. ;
Jentzen, Walter ;
Stahl, Alexander ;
Bockisch, Andreas ;
Rosenbaum-Krumme, Sandra J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 :48-56
[12]   Assessment of Minimum 124I Activity Required in Uptake Measurements Before Radioiodine Therapy for Benign Thyroid Diseases [J].
Gabler, Anja S. ;
Kuehnel, Christian ;
Winkens, Thomas ;
Freesmeyer, Martin .
JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (08) :1201-1206
[13]  
Guiraud-Vitaux F, 2001, CELL MOL BIOL, V47, P495
[14]   EANM Dosimetry Committee Series on Standard Operational Procedures for Pre-Therapeutic Dosimetry II. Dosimetry prior to radioiodine therapy of benign thyroid diseases [J].
Haenscheid, Heribert ;
Canzi, Cristina ;
Eschner, Wolfgang ;
Flux, Glenn ;
Luster, Markus ;
Strigari, Lidia ;
Lassmann, Michael .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (07) :1126-1134
[15]   Dosimetry prior to I-131-therapy of benign thyroid disease [J].
Haenscheid, Heribert ;
Lassmann, Michael ;
Reiners, Christoph .
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2011, 21 (04) :250-257
[16]   Self-stunning in thyroid ablation:: evidence from comparative studies of diagnostic 131I and 123I [J].
Hilditch, TE ;
Dempsey, MF ;
Bolster, AA ;
McMenemin, RM ;
Reed, NS .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (06) :783-788
[17]   Radioiodine therapy of benign thyroid disorders: what are the effective thyroidal half-life and uptake of 131I? [J].
Kobe, Carsten ;
Eschner, Wolfgang ;
Wild, Markus ;
Rahlff, Ilka ;
Sudbrock, Ferdinand ;
Schmidt, Matthias ;
Dietlein, Markus ;
Schicha, Harald .
NUCLEAR MEDICINE COMMUNICATIONS, 2010, 31 (03) :201-205
[18]  
Lassmann M, 2004, J NUCL MED, V45, P619
[19]   DISCREPANCIES IN THYROID UPTAKE VALUES - USE OF COMMERCIAL THYROID PROBE SYSTEMS VERSUS SCINTILLATION CAMERAS [J].
LEE, KH ;
SIEGEL, ME ;
KFERNANDEZ, OA .
CLINICAL NUCLEAR MEDICINE, 1995, 20 (03) :199-202
[20]  
Lundh C, 2007, J NUCL MED, V48, P481