On the effective point of measurement in megavoltage photon beams

被引:73
作者
Kawrakow, Iwan [1 ]
机构
[1] NRC, Ionizing Radiat Stand, Ottawa, ON K1A 0R6, Canada
关键词
D O I
10.1118/1.2201147
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This paper presents a numerical investigation of the effective point of measurement of thimble ionization chambers in megavoltage photon beams using Monte Carlo simulations with the EGSNRC system. It is shown that the effective point of measurement for relative photon beam dosimetry depends on every detail of the chamber design, including the cavity length, the mass density of the wall material, and the size of the central electrode, in addition to the cavity radius. Moreover. the effective point of measurement also depends on the beam quality and the field size. The paper therefore argues that the upstream shift of 0.6 times the cavity radius, recommended in current dosimetry protocols, is inadequate for accurate relative photon beam dosimetry, particularly in the build-up region. On the other hand, once the effective point of measurement is selected appropriately, measured depth-ionization curves can be equated to measured depth-dose curves for all depths within +/-0.5%.
引用
收藏
页码:1829 / 1839
页数:11
相关论文
共 29 条
[1]   Validation of Monte Carlo calculated surface doses for megavoltage photon beams [J].
Abdel-Rahman, W ;
Seuntjens, JP ;
Verhaegen, F ;
Deblois, F ;
Podgorsak, EB .
MEDICAL PHYSICS, 2005, 32 (01) :286-298
[2]   AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams [J].
Almond, PR ;
Biggs, PJ ;
Coursey, BM ;
Hanson, WF ;
Huq, MS ;
Nath, R ;
Rogers, DWO .
MEDICAL PHYSICS, 1999, 26 (09) :1847-1870
[3]   THE STATUS OF HIGH-ENERGY PHOTON AND ELECTRON-BEAM DOSIMETRY 5 YEARS AFTER THE IMPLEMENTATION OF THE IAEA CODE OF PRACTICE IN THE NORDIC COUNTRIES [J].
ANDREO, P .
ACTA ONCOLOGICA, 1993, 32 (05) :483-500
[4]  
[Anonymous], PIRS702REVB NAT RES
[5]  
[Anonymous], [No title captured]
[6]   Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs [J].
Chibani, O ;
Ma, CMC .
MEDICAL PHYSICS, 2003, 30 (08) :1990-2000
[7]   Dose discrepancies between Monte Carlo calculations and measurements in the buildup region for a high-energy photon beam [J].
Ding, GX .
MEDICAL PHYSICS, 2002, 29 (11) :2459-2463
[8]   Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: results of Monte Carlo simulations for a Varian 2100EX accelerator [J].
Ding, GX .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (07) :1025-1046
[9]  
DUTRIEX A, 1976, HIGH ENERGY PHOTONS, P204
[10]  
EWEN HM, COMMUNICATION