Effect of moist heat reprocessing of N95 respirators on SARS-CoV-2 inactivation and respirator function

被引:44
作者
Daeschler, Simeon C. [1 ]
Manson, Niclas [2 ,3 ,4 ]
Joachim, Kariym [3 ,4 ]
Chin, Alex W. H. [5 ]
Chan, Katelyn [1 ]
Chen, Paul Z. [6 ]
Tajdaran, Kiana [1 ]
Mirmoeini, Kaveh [1 ]
Zhang, Jennifer J.
Maynes, Jason T. [7 ]
Zhang, Libo [7 ]
Science, Michelle
Darbandi, Ali [1 ]
Stephens, Derek [8 ]
Gu, Frank [6 ]
Poon, Leo L. M. [5 ]
Borschel, Gregory H. [9 ,10 ]
机构
[1] Hosp Sick Children SickKids, SickKids Res Inst, Toronto, ON, Canada
[2] Hosp Sick Children SickKids Occupat Hlth & Safety, Toronto, ON, Canada
[3] Hosp Sick Children SickKids, Div Plast & Reconstruct Surg, Toronto, ON, Canada
[4] Univ Toronto, Toronto, ON, Canada
[5] Univ Hong Kong, LKS Fac Med, Sch Publ Hlth, Pokfulam, Hong Kong, Peoples R China
[6] Univ Toronto, Chem Engn & Appl Chem, Toronto, ON, Canada
[7] Hosp Sick Children, Dept Anesthesia & Pain Med, Toronto, ON, Canada
[8] Hosp Sick Children, Div Infect Dis Sci & Child Hlth Evaluat Sci, Toronto, ON, Canada
[9] Hosp Sick Children, Inst Biomat & Biomed Engn, Toronto, ON, Canada
[10] Hosp Sick Children, Div Plast & Reconstruct Surg, Toronto, ON, Canada
基金
美国国家卫生研究院;
关键词
D O I
10.1503/cmaj.201203
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Unprecedented demand for N95 respirators during the coronavirus disease 2019 (COVID-19) pandemic has led to a global shortage of these masks. We validated a rapidly applicable, low-cost decontamination protocol in compliance with regulatory standards to enable the safe reuse of N95 respirators. METHODS: We inoculated 4 common models of N95 respirators with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and evaluated viral inactivation after disinfection for 60 minutes at 70 degrees C and 0% relative humidity. Similarly, we evaluated thermal disinfection at 0% to 70% relative humidity for masks inoculated with Escherichia coli. We assessed masks subjected to multiple cycles of thermal disinfection for structural integrity using scanning electron microscopy and for protective functions using standards of the United States National Institute for Occupational Safety and Health for particle filtration efficiency, breathing resistance and respirator fit. RESULTS: A single heat treatment rendered SARS-CoV-2 undetectable in all mask samples. Compared with untreated inoculated control masks, E. coli cultures at 24 hours were virtually undetectable from masks treated at 70 degrees C and 50% relative humidity (optical density at 600 nm wavelength, 0.02 +/- 0.02 v. 2.77 +/- 0.09, p < 0.001), but contamination persisted for masks treated at lower relative humidity. After 10 disinfection cycles, masks maintained fibre diameters similar to untreated masks and continued to meet standards for fit, filtration efficiency and breathing resistance. INTERPRETATION: Thermal disinfection successfully decontaminated N95 respirators without impairing structural integrity or function. This process could be used in hospitals and long-term care facilities with commonly available equipment to mitigate the depletion of N95 masks.
引用
收藏
页码:E1189 / E1197
页数:9
相关论文
共 31 条
[1]   A scalable method of applying heat and humidity for decontamination of N95 respirators during the COVID-19 crisis [J].
Anderegg, Loic ;
Meisenhelder, Cole ;
Ngooi, Chiu Oan ;
Liao, Lei ;
Xiao, Wang ;
Chu, Steven ;
Cui, Yi ;
Doyle, John M. .
PLOS ONE, 2020, 15 (07)
[2]  
Angadjivand SJM, US2000 [patent], Patent No. 2000
[3]  
[Anonymous], 2020, FACT SHEET HEALTHC P
[4]  
[Anonymous], 2020, APP A 1910 134 FIT 1
[5]  
[Anonymous], 2020, REC GUID EXT US LTD
[6]  
[Anonymous], 2020, DEC 3M FILT FAC RESP
[7]   Coronavirus Survival on Healthcare Personal Protective Equipment [J].
Casanova, Lisa ;
Rutala, William A. ;
Weber, David J. ;
Sobsey, Mark D. .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2010, 31 (05) :560-561
[8]  
Centers for Disease Control and Prevention, Summary for Healthcare Facilities: Strategies for Optimizing the Supply of PPE During Shortages
[9]  
Chin AWH, 2020, LANCET MICROBE, V1, pE10, DOI [10.1016/S2666-5247(20)30003-3, 10.1016/S2666-5247(20)30095-1]
[10]  
COVID-19 Taskforce of the Department of Infectious Diseases and the IT Service, 2020, INT SURV COVID 19 IT