A Photoacoustic Imaging Device Using Piezoelectric Micromachined Ultrasound Transducers (PMUTs)

被引:56
作者
Dangi, Ajay [1 ]
Cheng, Christopher Y. [2 ,3 ]
Agrawal, Sumit [1 ]
Tiwari, Sudhanshu [4 ]
Datta, Gaurav Ramesh [5 ]
Benoit, Robert R. [6 ]
Pratap, Rudra [4 ]
Trolier-Mckinstry, Susan [2 ,3 ]
Kothapalli, Sri-Rajasekhar [1 ,7 ]
机构
[1] Penn State Univ, Dept Biomed Engn, University Pk, PA 16802 USA
[2] Penn State Univ, Dept Mat Sci & Engn, University Pk, PA 16802 USA
[3] Penn State Univ, Mat Res Inst, University Pk, PA 16802 USA
[4] Indian Inst Sci, Ctr Nano Sci & Engn, Bengaluru 560012, India
[5] Penn State Univ, Dept Elect Engn, University Pk, PA 16802 USA
[6] US Army, Res Lab, Sensors & Electron Devices Directorate, Adelphi, MD 20783 USA
[7] Penn State Univ, Penn State Canc Inst, Hershey, PA 17033 USA
基金
美国国家科学基金会;
关键词
Microelectromechanical systems; piezoelectric micromachined ultrasound transducers (PMUTs); photoacoustic imaging (PAI); ultrasound imaging; CMUT ARRAYS; TOMOGRAPHY; MICROSCOPY; RECEIVER;
D O I
10.1109/TUFFC.2019.2956463
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A linear piezoelectric micromachined ultrasound transducer (PMUT) array was fabricated and integrated into a device for photoacoustic imaging (PAI) of tissue phantoms. The PMUT contained 65 array elements, with each element having 60 diaphragms of 60 mu m diameter and 75 mu m pitch. A lead zirconate titanate (PZT) thin film was used as the piezoelectric layer. The in-air vibration response of the PMUT array elements showed a first mode resonance between 6 and 8 MHz. Hydrophone measurements showed 16.2 kPa average peak ultrasound pressure output at 7.5 mm from one element excited with 5 V-pp input. A receive sensitivity of similar to 0.48 mV/kPa was observed for a PMUT array element with 0 dB gain. The PMUT array was bonded to a custom-printed circuit board to enable compact integration with an optical fiber bundle for PAI. A broad photoacoustic bandwidth of similar to 89% was observed for the photoacoustic response captured from absorbing pencil lead targets. Linear scanning of a single element of a PMUT array was performed on different tissue phantoms embedded with light-absorbing targets to successfully demonstrate B-mode PAI using PMUTs.
引用
收藏
页码:801 / 809
页数:9
相关论文
共 52 条
[1]   Potential Role of Coregistered Photoacoustic and Ultrasound Imaging in Ovarian Cancer Detection and Characterization [J].
Aguirre, Andres ;
Ardeshirpour, Yasaman ;
Sanders, Mary M. ;
Brewer, Molly ;
Zhu, Quing .
TRANSLATIONAL ONCOLOGY, 2011, 4 (01) :29-37
[2]  
Ahn H, 2014, INT CONF UBIQ ROBOT, P73, DOI 10.1109/URAI.2014.7057398
[3]  
[Anonymous], 2013, P WORLD MOL IM C
[4]  
[Anonymous], 2007, American National Standard for Safe Use of Lasers
[5]  
ANSI Z136.1-2007
[6]   Biomedical photoacoustic imaging [J].
Beard, Paul .
INTERFACE FOCUS, 2011, 1 (04) :602-631
[7]   Top Orthogonal to Bottom Electrode (TOBE) 2-D CMUT Arrays for 3-D Photoacoustic Imaging [J].
Chee, Ryan K. W. ;
Sampaleanu, Alexander ;
Rishi, Deepak ;
Zemp, Roger J. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (08) :1393-1395
[8]   AlN-based piezoelectric micromachined ultrasonic transducer for photoacoustic imaging [J].
Chen, Bingzhang ;
Chu, Futong ;
Liu, Xingzhao ;
Li, Yanrong ;
Rong, Jian ;
Jiang, Huabei .
APPLIED PHYSICS LETTERS, 2013, 103 (03)
[9]   A Pixel Pitch-Matched Ultrasound Receiver for 3-D Photoacoustic Imaging With Integrated Delta-Sigma Beamformer in 28-nm UTBB FD-SOI [J].
Chen, Man-Chia ;
Perez, Aldo Pena ;
Kothapalli, Sri-Rajasekhar ;
Cathelin, Philippe ;
Cathelin, Andreia ;
Gambhir, Sanjiv Sam ;
Murmann, Boris .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2017, 52 (11) :2843-2856
[10]   Quantitative spectroscopic photoacoustic imaging: a review [J].
Cox, Ben ;
Laufer, Jan G. ;
Arridge, Simon R. ;
Beard, Paul C. .
JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (06)