Bioanalytical chromatographic method validation according to current regulations, with a special focus on the non-well defined parameters limit of quantification, robustness and matrix effect

被引:193
作者
Gonzalez, Oskar [1 ,2 ]
Encarnacion Blanco, Maria [1 ]
Iriarte, Gorka [3 ]
Bartolome, Luis [4 ]
Itxaso Maguregui, Miren [1 ]
Alonso, Rosa M. [1 ]
机构
[1] Basque Country Univ EHU, Dept Analyt Chem, Fac Sci & Technol, Bilbao 48080, Basque Country, Spain
[2] Leiden Univ, LACDR, Analyt Biosci Div, NL-2333 CC Leiden, Netherlands
[3] Basque Govt, Publ Hlth & Addict Directorate, Lab Publ Hlth Alava, Vitoria 01002, Basque Country, Spain
[4] Basque Country Univ EHU, Fac Sci & Technol, Cent Analyt Serv SGIker, Bilbao 48080, Basque Country, Spain
关键词
Method validation; Bioanalysis; Limit of quantification; Robustness; Matrix effect; LC-MS/MS METHOD; QUANTITATIVE ANALYTICAL PROCEDURES; TANDEM MASS-SPECTROMETRY; MEDICINES AGENCY GUIDELINE; COUNTER ION IMPACT; HUMAN PLASMA; RECENT ISSUES; ELECTROSPRAY-IONIZATION; SFSTP PROPOSAL; WHITE PAPER;
D O I
10.1016/j.chroma.2014.03.077
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Method validation is a mandatory step in bioanalysis, to evaluate the ability of developed methods in providing reliable results for their routine application. Even if some organisations have developed guidelines to define the different parameters to be included in method validation (FDA, EMA); there are still some ambiguous concepts in validation criteria and methodology that need to be clarified. The methodology to calculate fundamental parameters such as the limit of quantification has been defined in several ways without reaching a harmonised definition, which can lead to very different values depending on the applied criterion. Other parameters such as robustness or ruggedness are usually omitted and when defined there is not an established approach to evaluate them. Especially significant is the case of the matrix effect evaluation which is one of the most critical points to be studied in LC-MS methods but has been traditionally overlooked. Due to the increasing importance of bioanalysis this scenario is no longer acceptable and harmonised criteria involving all the concerned parties should be arisen. The objective of this review is thus to discuss and highlight several essential aspects of method validation, focused in bioanalysis. The overall validation process including common validation parameters (selectivity, linearity range, precision, accuracy, stability...) will be reviewed. Furthermore, the most controversial parameters (limit of quantification, robustness and matrix effect) will be carefully studied and the definitions and methodology proposed by the different regulatory bodies will be compared. This review aims to clarify the methodology to be followed in bioanalytical method validation, facilitating this time consuming step. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 27
页数:18
相关论文
共 162 条
[1]   The Broadening Scope of Validation: Towards Best Practices in the World of Bioanalysis [J].
Abbott, Richard W. .
BIOANALYSIS, 2010, 2 (04) :703-708
[2]   Selectivity versus specificity in chromatographic analytical methods [J].
Aboul-Enein, HY .
ACCREDITATION AND QUALITY ASSURANCE, 2000, 5 (05) :180-181
[3]  
Agencia Nacional de Vigilancia Sanitaria, 2003, 8992003 RE
[4]  
Agenicia Nacional de Vigilancia Sanitaria, 2012, 272012 RDC
[5]  
Ahmad S, 2012, J PHARM BIOALLIED SC, V4, P267, DOI 10.4103/0975-7406.103234
[6]   Anidulafungin-challenges in development and validation of an LC-MS/MS bioanalytical method validated for regulated clinical studies [J].
Alebic-Kolbah, Tanja ;
Modesitt, Michael S. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (6-7) :2043-2055
[7]   Linear regression for calibration lines revisited: weighting schemes for bioanalytical methods [J].
Almeida, AM ;
Castel-Branco, MM ;
Falcao, AC .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 774 (02) :215-222
[8]   Direct injection LC-MS/MS method for identification and quantification of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine and 3,4-methylenedioxymethamphetamine in urine drug testing [J].
Andersson, M. ;
Gustavsson, E. ;
Stephanson, N. ;
Beck, O. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 861 (01) :22-28
[9]  
[Anonymous], 2006, REV SAUDE PUBL, V40, P361
[10]  
[Anonymous], [No title captured]