The Pollexograph®: A New Device for Palmar Abduction Measurements of the Thumb

被引:35
作者
de Kraker, M. [1 ,2 ]
Selles, R. W. [2 ]
Schreuders, T. A. R. [2 ]
Hovius, S. E. R.
Stam, H. J. [2 ]
机构
[1] Erasmus MC, Univ Med Ctr, Dept Plast & Reconstruct Surg, NL-3015 GD Rotterdam, Netherlands
[2] Erasmus MC, Dept Rehabil Med, NL-3015 GD Rotterdam, Netherlands
关键词
GENERALIZABILITY THEORY; RELIABILITY ASSESSMENT; EXTENSION; MOTION;
D O I
10.1016/j.jht.2008.12.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study Design: Clinical measurement, cross sectional. Purpose: To introduce a new measurement device, the Pollexograph (R), to easily measure palmar thumb abduction, and to compare its reliability with conventional goniometry. Methods: Fourteen hand therapists measured palmar abduction of the same healthy subject with the Pollexograph and a conventional goniometer. In addition, intrarater reliability of the Pollexograph was Studied in 21 patients with a hypoplastic thumb. Results: Variance between measurements of the same subject measured by the hand therapist was 2-6 times smaller with the Pollexograph compared to conventional goniometry. Pollexograph intrarater reliability in hypoplastic thumb patients was excellent (intraclass correlation coefficient (ICC) = 0.98-0.99). Conclusions: A now tool to measure palmar abduction in clinical care, the Pollexograph, has been introduced. The Pollexograph reduces variability between raters when measuring the same subject compared with conventional goniometry and excellent measurement reliability in hypoplastic thumb patients.
引用
收藏
页码:271 / 276
页数:6
相关论文
共 21 条
  • [1] *AM MED ASS, GUID EV PERM IMP, P28
  • [2] *AM SOC HAND THER, CLIN ASS REC, P64
  • [3] DOCUMENTATION OF THE 1ST WEB SPACE ANGLE
    BHATTACHARYA, S
    PANDEY, SD
    CHANDRA, R
    SINGH, GK
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1989, 14B (03) : 298 - 300
  • [4] BRAND PW, 1964, LEPROSY THEORY PRACT, P485
  • [5] Buck-Gramcko D, 1976, Handchirurgie, V8, P65
  • [6] CHIN HY, 2000, J HAND SURG, V25, P195
  • [7] Three-dimensional rotations of human three-joint fingers: an optoelectronic measurement. Preliminary results
    Degeorges, R
    Parasie, J
    Mitton, D
    Imbert, N
    Goubier, JN
    Lavaste, F
    [J]. SURGICAL AND RADIOLOGIC ANATOMY, 2005, 27 (01) : 43 - 50
  • [8] Fleiss JL., 1986, DESIGN ANAL CLIN EXP
  • [9] Thumb carpometacarpal osteoarthritis: Arthrodesis compared with ligament reconstruction and tendon interposition
    Hartigan, BJ
    Stern, PJ
    Kiefhaber, TR
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (10) : 1470 - 1478
  • [10] A torque-controlled device to measure passive abduction of the thumb carpometacarpal joint
    Harvey, Lisa
    de Jong, Inge
    Goehl, Gerlinde
    Armstrong, Belinda
    Allaous, Jeanine
    [J]. JOURNAL OF HAND THERAPY, 2006, 19 (04) : 403 - 408