Experimental evaluation of a multi-pinhole collimator for a small organ by using a small-field-of-view gamma camera

被引:1
作者
Bae, Jaekeon [1 ]
Bae, Seungbin [1 ]
Jung, Young-Jun [1 ]
Lee, Kisung [1 ,2 ]
Kim, Yongkwon [3 ]
Joung, Jinhun [3 ]
Kim, Kyeong Min [4 ]
Kim, Hee-Joung [5 ]
机构
[1] Korea Univ, Dept Bioconvergence Engn, Seoul 02841, South Korea
[2] Korea Univ, Sch Biomed Engn, Seoul 02841, South Korea
[3] NuCare Inc, Incheon 21990, South Korea
[4] Korea Inst Radiol & Med Sci, Seoul 01812, South Korea
[5] Yonsei Univ, Dept Radiol Sci, Wonju 26493, South Korea
基金
新加坡国家研究基金会;
关键词
Single-photon emission computed tomography; Experimental data; Multi-pinhole collimator; Collimator modeling; Image reconstruction; ULTRA-HIGH-RESOLUTION; SPECT; PERFORMANCE; DESIGN; TOMOGRAPHY; SYSTEM;
D O I
10.3938/jkps.70.416
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The aim of this study is to design and evaluate a multi-pinhole (MP) collimator for a gamma imaging system that requires a high sensitivity, organ-specific, and small footprint. To ensure these requirements, we designed an eight-hole collimator that can be integrated into a small field-of-view gamma camera for imaging the thyroid or relatively sized organs. Each pinhole was designed to have a cylindrical shape with a 2-mm diameter. Experiments were performed with both a two-sphere phantom and a four-rod phantom. An image reconstruction based on the maximum likelihood expectation maximization with the distance-driven method was used for obtaining a 3-dimensional image. For improving the uniformity of the reconstruction image, we modeled the sensitivity of the cylindrical pinhole by calculating the area of the overlapped circle. The results show that the full width at half maximum values of the two-sphere phantom and the four-rod phantom were 7.56 mm (5-mm-diameter source) and 6.84 mm (5-mm-diameter rod), respectively. The scanning time can be reduced by up to 20 minutes in small-organ applications by using developed MP collimator. Thus, the results indicate that the proposed MP collimator is suitable for a fast scan time, as well as for organ-specific and small-footprint applications.
引用
收藏
页码:416 / 423
页数:8
相关论文
共 22 条
  • [1] [Anonymous], 2002, 2002 IEEE NUCL SCI S
  • [2] Design and Performance Investigation of a Multi-pinhole Collimator for a Small Field of View Gamma Imaging System
    Bae, Jaekeon
    Bae, Seungbin
    Lee, Kisung
    Choi, Yong
    Kim, Yongkwon
    Joung, Jinhun
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (07) : 970 - 975
  • [3] Barrett H.H., 1981, RADIOLOGICAL IMAGING
  • [4] Beekman FJ, 2005, J NUCL MED, V46, P1194
  • [5] A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential
    Bocher, Moshe
    Blevis, Ira M.
    Tsukerman, Leonid
    Shrem, Yigal
    Kovalski, Gil
    Volokh, Lana
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (10) : 1887 - 1902
  • [6] Small-Animal SPECT and SPECT/CT: Important Tools for Preclinical Investigation
    Franc, Benjamin L.
    Acton, Paul D.
    Mari, Carina
    Hasegawa, Bruce H.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (10) : 1651 - 1663
  • [7] Giussani A, 2013, IMAGING NUCL MED
  • [8] PINHOLE COLLIMATION FOR ULTRA-HIGH-RESOLUTION, SMALL-FIELD-OF-VIEW SPECT
    JASZCZAK, RJ
    LI, JY
    WANG, HL
    ZALUTSKY, MR
    COLEMAN, RE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) : 425 - 437
  • [9] ANALYSIS OF EMISSION TOMOGRAPHIC SCAN DATA - LIMITATIONS IMPOSED BY RESOLUTION AND BACKGROUND
    KESSLER, RM
    ELLIS, JR
    EDEN, M
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (03) : 514 - 522
  • [10] IMAGE SEPARATION RADIOISOTOPE SCANNING
    KUHL, DE
    EDWARDS, RQ
    [J]. RADIOLOGY, 1963, 80 (04) : 653 - 662