International Academy of Cytology Yokohama System for Reporting Breast Fine-Needle Aspiration Biopsy Cytopathology: A Review of Predictive Values and Risks of Malignancy

被引:32
作者
Hoda, Raza S. [1 ]
Brachtel, Elena F. [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Pathol, Div Cytopathol, 55 Fruit St,WRN2, Boston, MA 02114 USA
关键词
Breast cytology; Breast fine-needle aspiration biopsy cytology; Yokohama system breast cytology; Predictive values; CARCINOMA IN-SITU; DIAGNOSTIC-ACCURACY; INVASIVE-CARCINOMA; UNIFORM APPROACH; TRIPLE-TEST; LESIONS; CANCER; FNA; EXPERIENCE; MASSES;
D O I
10.1159/000500704
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Objective: We aimed to assess the risk of malignancy (ROM) and predictive values in prior breast cytology studies as a basis for the new International Academy of Cytology (IAC) Yokohama system for reporting breast fine-needle aspiration biopsy (FNAB) cytology, which classifies cytologic diagnoses into 5 categories: (1) insufficient material, (2) benign, (3) atypical, (4) suspicious of malignancy, and (5) malignant. Study Design: Publications between January 1, 1997, and December 31, 2017, that studied the performance characteristics of FNAB from palpable and nonpalpable breast masses were identified through the PubMed database. Data for number of total cases and cases within each diagnostic category, if available, were collected. Performance characteristics, including absolute sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and ROM for each category were recorded or, when possible, calculated. Results: The literature review resulted in a case cohort of 33,341 breast FNABs, drawn from 27 studies. Pooling these cases together, the ROM for insufficient material, benign, atypical, suspicious, and malignant were 30.3, 4.7, 51.5, 85.4, and 98.7%, respectively. The complete sensitivity and specificity were 96.3 and 98.8%, correspondingly. The PPV and NPV were 98.7 and 95.3%, correspondingly. The false-negative and false-positive rates were 3.7 and 1.0%, respectively. Conclusions: This meta-analysis demonstrates that the diagnostic categories of the new IAC Yokohama System each carry an implied ROM, which increases from the benign to malignant categories. This study also shows the high sensitivity and specificity of FNAB for breast lesions.
引用
收藏
页码:292 / 301
页数:10
相关论文
共 60 条
  • [1] Abati A, 1997, DIAGN CYTOPATHOL, V16, P295
  • [2] Should Fine-Needle Aspiration Cytology be the First Choice Diagnostic Modality for Assessment of All Nonpalpable Breast Lesions? The Experience of a Breast Cancer Screening Center in Alexandria, Egypt
    Abdel-Hadi, Mona
    Abdel-Hamid, Gehane F.
    Abdel-Razek, Naglaa
    Fawzy, Rawia K.
    [J]. DIAGNOSTIC CYTOPATHOLOGY, 2010, 38 (12) : 880 - 889
  • [3] Accuracy of Fine-Needle Aspiration Cytology in the Diagnosis of Breast Cancer a Single-Center Retrospective Study from Turkey with Cytohistological Correlation in 733 Cases
    Aker, Fugen
    Gumrukcu, Gulistan
    Onomay, Burcu Celik
    Erkan, Murat
    Gurleyik, Gunay
    Kilicoglu, Gamze
    Karagullu, Hikmet
    [J]. DIAGNOSTIC CYTOPATHOLOGY, 2015, 43 (12) : 978 - 986
  • [4] [Anonymous], 2014, Rosen's Breast Pathology
  • [5] Fine-needle aspiration of clinically suspicious palpable breast masses with histopathologic correlation
    Ariga, R
    Bloom, K
    Reddy, VB
    Kluskens, L
    Francescatti, D
    Dowlat, K
    Siziopikou, P
    Gattuso, P
    [J]. AMERICAN JOURNAL OF SURGERY, 2002, 184 (05) : 410 - 413
  • [6] Arisio R, 1998, DIAGN CYTOPATHOL, V18, P462, DOI 10.1002/(SICI)1097-0339(199806)18:6<462::AID-DC16>3.0.CO
  • [7] 2-F
  • [8] Boerner S, 1999, CANCER CYTOPATHOL, V87, P19, DOI 10.1002/(SICI)1097-0142(19990225)87:1<19::AID-CNCR4>3.0.CO
  • [9] 2-K
  • [10] Boerner S, 1998, CANCER CYTOPATHOL, V84, P344, DOI 10.1002/(SICI)1097-0142(19981225)84:6<344::AID-CNCR5>3.3.CO