In vivo MR imaging of magnetically labeled human embryonic stem cells

被引:52
作者
Tallheden, T.
Nannmark, U.
Lorentzon, M.
Rakotonirainy, O.
Soussi, B.
Waagstein, F.
Jeppsson, A.
Sjogren-Jansson, E.
Lindahl, A.
Omerovic, E. [1 ]
机构
[1] Gothenburg Univ, Sahlgrenska Acad, Wallenberg Lab, S-41345 Gothenburg, Sweden
[2] Univ Gothenburg, Dept Cardiothorac Surg, Gothenburg, Sweden
[3] Univ Gothenburg, Dept Clin Chem & Transfus Med, Gothenburg, Sweden
[4] Univ Gothenburg, Inst Anat & Cell Biol, Gothenburg, Sweden
[5] Cellaris AB, Biotech Ctr, Arvid Wallgrensbacke, Gothenburg, Sweden
关键词
human embryonic stem cells; magnetic resonance imaging; cell tracking; iron-labeling; stem cell therapy;
D O I
10.1016/j.lfs.2006.05.021
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Introduction: Human embryonic stem cells (hES) have emerged as a potentially new therapeutic approach for treatment of heart and other diseases applying the concept of regenerative medicine. A method for in vivo visualization and tracking of transplanted hES would increase our understanding, of in vivo hES behavior in both experimental and clinical settings. The aim of this study was to evaluate the feasibility of magnetic labeling and visualization of hES with magnetic resonance imaging (MRI). Methods: hES were established and expanded according to standard procedures. After expansion, the cells were cultured under feeder free conditions and magnetically labeled by addition of dextran-coated Ferrum-oxide particles (Endorem (R)) to the medium. Accumulation of small particles of iron-oxide (SPIO) in hES was assessed by Prussian blue staining and electron microscopy. For in vitro MRI, the labeled and unlabeled hES were examined in cell solution and after transplantation into explanted mouse heart (similar to 100 000 cells) on a Bruker Avance DMX 500 vertical magnet at 11.75 T. A multi-slice, multi spin-echo T-2-weighted images were obtained. For in vivo imaging, the experiments were performed on male Sprague-Dawley using Bruker Biospec 2.35 T magnet. The hES were directly injected (similar to 500000 cells) after surgical procedure (thoracotomy) into anterior left ventricular (LV) wall. Multi-slice T-2-weighted gradient echo images were obtained using cardiac gating. Results: hES appeared to be unaffected by magnetic labeling and maintained their ability to proliferate and differentiate. No additive agent for membrane permeabilisation was needed for facilitation of intracellular SPIO accumulation. Prussian blue and electron microscopy have revealed numerous iron particles in the cytoplasm of hES. On T-2-weighted images, the labeled cells have shown well-defined hyopintense areas at the site of injection in anterior LV wall both in vitro and in vivo. Conclusions: It is feasible to magnetically label and visualize hES both in vitro and in vivo. MR visualization of magnetically labeled hES may be a valuable tool for in vivo tracking of hES. (c) 2006 Published by Elsevier Inc.
引用
收藏
页码:999 / 1006
页数:8
相关论文
共 28 条
[1]   Clonally derived human embryonic stem cell lines maintain pluripotency and proliferative potential for prolonged periods of culture [J].
Amit, M ;
Carpenter, MK ;
Inokuma, MS ;
Chiu, CP ;
Harris, CP ;
Waknitz, MA ;
Itskovitz-Eldor, J ;
Thomson, JA .
DEVELOPMENTAL BIOLOGY, 2000, 227 (02) :271-278
[2]   Intracytoplasmic tagging of cells with ferumoxides and transfection agent for cellular magnetic reisonance imaging after cell transplantation: Methods and techniques [J].
Arbab, AS ;
Bashaw, LA ;
Miller, BR ;
Jordan, EK ;
Bulte, JWM ;
Frank, JA .
TRANSPLANTATION, 2003, 76 (07) :1123-1130
[3]   Transplantation of progenitor cells and regeneration enhancement in acute myocardial infarction -: (TOPCARE-AMI) [J].
Assmus, B ;
Schächinger, V ;
Teupe, C ;
Britten, M ;
Lehmann, R ;
Döbert, N ;
Grünwald, F ;
Aicher, A ;
Urbich, C ;
Martin, H ;
Hoelzer, D ;
Dimmeler, S ;
Zeiher, AM .
CIRCULATION, 2002, 106 (24) :3009-3017
[4]  
Bordat C, 2000, J MAGN RESON IMAGING, V12, P505, DOI 10.1002/1522-2586(200009)12:3<505::AID-JMRI18>3.0.CO
[5]  
2-A
[6]   Infarct remodeling after intracoronary progenitor cell treatment in patients with acute myocardial infarction (TOPCARE-AMI) -: Mechanistic insights from serial contrast-enhanced magnetic resonance imaging [J].
Britten, MB ;
Abolmaali, ND ;
Assmus, B ;
Lehmann, R ;
Honold, J ;
Schmitt, J ;
Vogl, TJ ;
Martin, H ;
Schächinger, V ;
Dimmeler, S ;
Zeiher, AM .
CIRCULATION, 2003, 108 (18) :2212-2218
[7]   In vivo magnetic resonance tracking of magnetically labeled cells after transplantation [J].
Bulte, JWM ;
Duncan, ID ;
Frank, JA .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2002, 22 (08) :899-907
[8]   Magnetic resonance fluoroscopy allows targeted delivery of mesenchymal stem cells to infarct borders in swine [J].
Dick, AJ ;
Guttman, MA ;
Raman, VK ;
Peters, DC ;
Pessanha, BSS ;
Hill, JM ;
Smith, S ;
Scott, G ;
McVeigh, ER ;
Lederman, RJ .
CIRCULATION, 2003, 108 (23) :2899-2904
[9]   Clinically applicable labeling of mammalian and stem cells by combining; Superparamagnetic iron oxides and transfection agents [J].
Frank, JA ;
Miller, BR ;
Arbab, AS ;
Zywicke, HA ;
Jordan, EK ;
Lewis, BK ;
Bryant, LH ;
Bulte, JWM .
RADIOLOGY, 2003, 228 (02) :480-487
[10]   Serial cardiac magnetic resonance imaging of injected mesenchymal stem cells [J].
Hill, JM ;
Dick, AJ ;
Raman, VK ;
Thompson, RB ;
Yu, ZX ;
Hinds, KA ;
Pessanha, BSS ;
Guttman, MA ;
Varney, TR ;
Martin, BJ ;
Dunbar, CE ;
McVeigh, ER ;
Lederman, RJ .
CIRCULATION, 2003, 108 (08) :1009-1014