Modelling dispersion of traffic pollution in a deep street canyon: Application of CFD and operational models
被引:69
作者:
Murena, Fabio
论文数: 0引用数: 0
h-index: 0
机构:
Univ Naples Federico 2, Dipartimento Ingn Chim, I-80125 Naples, ItalyUniv Naples Federico 2, Dipartimento Ingn Chim, I-80125 Naples, Italy
Murena, Fabio
[1
]
Favale, Giuseppe
论文数: 0引用数: 0
h-index: 0
机构:
Univ Naples Federico 2, Dipartimento Ingn Chim, I-80125 Naples, ItalyUniv Naples Federico 2, Dipartimento Ingn Chim, I-80125 Naples, Italy
Favale, Giuseppe
[1
]
Vardoulakis, Sotiris
论文数: 0引用数: 0
h-index: 0
机构:
Univ London London Sch Hyg & Trop Med, Publ & Environm Hlth Res Unit, London WC1E 7HT, EnglandUniv Naples Federico 2, Dipartimento Ingn Chim, I-80125 Naples, Italy
Vardoulakis, Sotiris
[2
]
Solazzo, Efisio
论文数: 0引用数: 0
h-index: 0
机构:
Univ Birmingham, Sch Geog Earth & Environm Sci, Div Environm Hlth & Risk Management, Birmingham B15 2TT, W Midlands, EnglandUniv Naples Federico 2, Dipartimento Ingn Chim, I-80125 Naples, Italy
Deep street canyon;
CO;
Dispersion modelling;
CFD;
WinOSPM;
EPSILON TURBULENCE MODEL;
AIR-POLLUTION;
FLOW-FIELD;
URBAN;
CANOPY;
SCALE;
OSPM;
D O I:
10.1016/j.atmosenv.2009.01.038
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
In this study, numerical modelling of the flow and concentration fields has been undertaken for a deep street canyon in Naples (Italy), having aspect ratio (i.e. ratio of the building height H to the street width W) H/W= 5.7. Two different modelling techniques have been employed: computational fluid dynamics (CFD) and operational dispersion modelling. The CFD simulations have been carried out by using the RNG k-epsilon turbulence model included in the commercial suite FLUENT, while operational modelling has been conducted by means of the WinOSPM model. Concentration fields obtained from model simulations have been compared with experimental data of CO concentrations measured at twovertical locations within the canyon. The CFD results are in good agreement with the experimental data, while poor agreement is observed for the WinOSPM results. This is because WinOSPM was originally developed and tested for street canyons with aspect ratio H/W congruent to 1. Large discrepancies in wind profiles Simulated within the canyon are observed between CFD and OSPM models. Therefore, a modification of the wind profile within the canyon is introduced in WinOSPM for extending its applicability to deeper canyons, leading to an improved agreement between modelled and experimental data. Further development of the operational dispersion model is required in order to reproduce the distinct air circulation patterns within deep street canyons. (C) 2009 Elsevier Ltd. All rights reserved.
机构:
Hong Kong Polytech Univ, Dept Civil & Struct Engn, Environm Engn Unit, Hong Kong, Hong Kong, Peoples R ChinaHong Kong Polytech Univ, Dept Civil & Struct Engn, Environm Engn Unit, Hong Kong, Hong Kong, Peoples R China
Chan, LY
;
Kwok, WS
论文数: 0引用数: 0
h-index: 0
机构:
Hong Kong Polytech Univ, Dept Civil & Struct Engn, Environm Engn Unit, Hong Kong, Hong Kong, Peoples R ChinaHong Kong Polytech Univ, Dept Civil & Struct Engn, Environm Engn Unit, Hong Kong, Hong Kong, Peoples R China
机构:
Hong Kong Polytech Univ, Dept Civil & Struct Engn, Environm Engn Unit, Hong Kong, Hong Kong, Peoples R ChinaHong Kong Polytech Univ, Dept Civil & Struct Engn, Environm Engn Unit, Hong Kong, Hong Kong, Peoples R China
Chan, LY
;
Kwok, WS
论文数: 0引用数: 0
h-index: 0
机构: