Seismic behaviour of combined steel framed-tube substructure with replaceable shear links

被引:16
作者
Guan, Binlin [1 ]
Su, Mingzhou [1 ,2 ]
Lian, Ming [1 ,2 ]
机构
[1] Xian Univ Architecture & Technol, Sch Civil Engn, Xian 710055, Peoples R China
[2] Minist Educ XAUAT, Key Lab Struct Engn & Earthquake Resistance, Xian 710055, Peoples R China
基金
中国国家自然科学基金;
关键词
Framed-tube structure; Cyclic test; Seismic behaviour; Shear link; End-plate connection; Numerical simulation; OVERSTRENGTH; FUSE;
D O I
10.1016/j.jcsr.2020.105968
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A combined steel framed-tube structure with replaceable shear links (SFTS-links) can make plasticity isolated to links for rapid replacement of damaged links and improve the applicability of SFTS-links with enhanced ductility in high-seismic zones. In this paper, the seismic performance of thirty-storey SETS-links and SFTS was compared by elasto-plastic time history and nonlinear static analyses. A 2/3-scale double half-storey, one-bay substructure was tested under cyclic loading in two stages. The substructure was repaired by replacing the damaged link in Stage I. Then the substructure restored to its original position was loaded to destruction in Stage II. Analysis of the substructure was conducted for two stages. The results indicate that ductility of SFTS-links is 34% higher than that of SFTS; the link can be replaced even at the story drift angle of 0.43%; replacing the damaged link can substantially improve the performance of the damaged structure; the ductile factor and the maximum viscous damping ratio of the specimen are 3.92, 0.39, respectively, and the maximum rotation angle and overstrength factor of the link are 0.147 rad, 1.54, respectively; the failure mode of the link is that expansion of the weld crack at the chamfer position of stiffeners causes tearing of link web and fracture of stiffeners. A numerical model is developed and verified with the test results. With increasing link length, initial stiffness, peak strength and cumulative energy dissipation decrease. It is recommended that the length ratio of the link should be 0.93-1.26 in SETS-links. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:19
相关论文
共 38 条
[1]  
AISC, 2010, 35810 AISC AISCANSI
[2]  
[Anonymous], 2010, GB 50011-2010
[3]  
[Anonymous], 2006, 7002006 GBT
[4]  
[Anonymous], 2017, 4152017 JGJT
[5]  
[Anonymous], 2016, AISC 341-16, P480, DOI [10.1201/b11248-8, DOI 10.1201/B11248-8]
[6]  
[Anonymous], 2017, GB 50017--2017
[7]  
[Anonymous], 2006, 12302006 GBT
[8]  
[Anonymous], 2000, 356 FEMA
[9]  
[Anonymous], 2010, 22812010 GBT
[10]  
[Anonymous], 2006, 12282006 GBT