A State-Space Dynamic Model for Photovoltaic Systems With Full Ancillary Services Support

被引:47
作者
Batzelis, Efstratios I. [1 ]
Anagnostou, Georgios [1 ]
Cole, Ian R. [2 ,3 ]
Betts, Thomas R. [2 ]
Pal, Bikash C. [1 ]
机构
[1] Imperial Coll London, Dept Elect & Elect Engn, London SW7 2AZ, England
[2] Loughborough Univ, Ctr Renewable Energy Syst Technol, Loughborough LE11 3TU, Leics, England
[3] Univ Cyprus, FOSS Res Ctr Sustainable Energy, Dept Elect & Comp Engn, CY-1678 Nicosia, Cyprus
基金
英国工程与自然科学研究理事会; 欧盟地平线“2020”;
关键词
Ancillary services; asymmetrical faults; discontinuous conduction mode (DCM); dynamic model; frequency response; Lambert W function; photovoltaic (PV) system; state-space model; two-stage system; CONNECTED PV SYSTEMS; STABILITY;
D O I
10.1109/TSTE.2018.2880082
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Large-scale photovoltaic (PV) integration to the network necessitates accurate modeling of PV system dynamics under solar irradiance changes and disturbances in the power system. Most of the available PV dynamic models in the literature are scope-specific, neglecting some control functions and employing simplifications. In this paper, a complete dynamic model for two-stage PV systems is presented, given in entirely state-space form and explicit equations that takes into account all power circuit dynamics and modern control functions. This is a holistic approach that considers a full range of ancillary services required by modern grid codes, supports both balanced and unbalanced grid operation, and accounts for the discontinuous conduction mode of the dc/dc converter of the system. The proposed dynamic model is evaluated and compared to other approaches based on the literature, against scenarios of irradiance variation, voltage sags, and frequency distortion. Simulation results in MATLAB/Simulink indicate high accuracy at low computational cost and complexity.
引用
收藏
页码:1399 / 1409
页数:11
相关论文
共 36 条
[21]  
Manias S.N., 2016, POWER ELECT MOTOR DR
[22]  
Mao XL, 2009, APPL POWER ELECT CO, P1964, DOI 10.1109/APEC.2009.4802942
[23]   Improving the Small Signal Stability of a PV-DE-Dynamic Load-Based Microgrid Using an Auxiliary Signal in the PV Control Loop [J].
Mishra, S. ;
Ramasubramanian, D. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2015, 30 (01) :166-176
[24]   Effects of Front-End Converter and DC-Link of a Utility-Scale PV Energy System on Dynamic Stability of a Power System [J].
Moradi-Shahrbabak, Zahra ;
Tabesh, Ahmadreza .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (01) :403-411
[25]   A generic model of two-stage grid-connected PV systems with primary frequency response and inertia emulation [J].
Nanou, Sotirios I. ;
Papakonstantinou, Apostolos G. ;
Papathanassiou, Stavros A. .
ELECTRIC POWER SYSTEMS RESEARCH, 2015, 127 :186-196
[26]   Modeling of a PV system with grid code compatibility [J].
Nanou, Sotirios I. ;
Papathanassiou, Stavros A. .
ELECTRIC POWER SYSTEMS RESEARCH, 2014, 116 :301-310
[27]   A generic transient PV system model for power quality studies [J].
Patsalides, Minas ;
Efthymiou, Venizelos ;
Stavrou, Andreas ;
Georghiou, George E. .
RENEWABLE ENERGY, 2016, 89 :526-542
[28]   Analytical model of mismatched photovoltaic fields by means of Lambert W-function [J].
Petrone, G. ;
Spagnuojo, G. ;
Vitelli, M. .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2007, 91 (18) :1652-1657
[29]   A model of PV generation suitable for stability analysis [J].
Tan, YT ;
Kirschen, DS ;
Jenkins, N .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (04) :748-755
[30]  
Western Electricity Coordinating Council Modeling and Validation Work Group, 2014, WECC SOL PLANT DYN M