Networking of near infrared spectroscopy instruments for rapeseed analysis: a comparison of different procedures

被引:32
作者
Tillmann, P
Reinhardt, TC
Paul, C
机构
[1] VDLUFA Qual Sicherung NIRS NIT, D-34128 Kassel, Germany
[2] Ingn Bur Dr Reinhardt, Abschnitt Nahes Infrarot, D-65199 Wiesbaden, Germany
[3] Fed Agr Res Ctr FAL, Inst Crop & Grassland Sci, D-38116 Braunschweig, Germany
关键词
NIR; near infrared spectroscopy; networking; calibration development; rapeseed; multivariate calibration;
D O I
10.1255/jnirs.269
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A comparison of several procedures to establish a network of near infrared (NIR) spectroscopy instruments for analytical applications with rapeseed [moisture, protein, oil, glucosinolates (GSL), oleic acid (C18:1)] is presented, The procedures are (a) calibration transfer with bias adjustment, (b) standardisation with different products and different number of samples, (c) calibration with spectra of different instruments and (d) the use of a repeatability file for mininising instrument differences, The most successful procedure proved to be the use of a repeatability file of spectra of the network instruments after standardisation using rapeseed samples. Following this procedure the standard deviation of analyses in a network could be reduced by 50-66% compared to a direct calibration transfer. Calibrations for constituents with high absorptivity (e,g, moisture) could be transferred directly without a bias correction, while those for constituents with a low absorptivity (e,g, GSL) had to be transferred using a repeatability file and standardised instruments.
引用
收藏
页码:101 / 107
页数:7
相关论文
共 17 条
[1]   Transfer of near-infrared multivariate calibrations without standards [J].
Blank, TB ;
Sum, ST ;
Brown, SD ;
Monfre, SL .
ANALYTICAL CHEMISTRY, 1996, 68 (17) :2987-2995
[2]   CALIBRATION TRANSFER ACROSS NEAR-INFRARED SPECTROMETRIC INSTRUMENTS USING SHENKS ALGORITHM - EFFECTS OF DIFFERENT STANDARDIZATION SAMPLES [J].
BOUVERESSE, E ;
MASSART, DL ;
DARDENNE, P .
ANALYTICA CHIMICA ACTA, 1994, 297 (03) :405-416
[3]  
DARDENNE P, 1992, ELLIS HOR S, P453
[4]   MULTIVARIATE CALIBRATION STANDARDIZATION [J].
DENOORD, OE .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1994, 25 (02) :85-97
[5]  
*INFR INT, 1995, NIRS 3 MAN VERS 3 10
[6]   DEVELOPMENT AND TRANSFERABILITY OF NEAR-INFRARED METHODS FOR DETERMINATION OF MOISTURE IN A FREEZE-DRIED INJECTION PRODUCT [J].
JONES, JA ;
LAST, IR ;
MACDONALD, BF ;
PREBBLE, KA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (11-12) :1227-1231
[7]  
Mark H., 1988, SPECTROSCOPY, V3, P28
[8]  
OSBORNE BG, 1983, J FOOD TECHNOL, V18, P453, DOI 10.1177/0047117804048489
[9]  
REINHARDT T, 1992, ENTWICKLUNG ANWENDUN
[10]   CALIBRATION TRANSFER BETWEEN NEAR-INFRARED REFLECTANCE SPECTROPHOTOMETERS [J].
SHENK, JS ;
WESTERHAUS, MO ;
TEMPLETON, WC .
CROP SCIENCE, 1985, 25 (01) :159-161