Percutaneous pinning of distal radius fractures: A biomechanical study

被引:47
作者
Naidu, SH
Capo, JT
Moulton, M
Ciccone, W
Radin, A
机构
[1] Hershey Medical Center, P.O. Box 850, Hershey
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 1997年 / 22A卷 / 02期
关键词
D O I
10.1016/S0363-5023(97)80159-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Mechanical testing of extra-articular distal radius fractures stabilized with percutaneous pins was performed. Twelve fresh-frozen unembalmed radii stripped of all soft tissues were used. An osteotomy with dorsal comminution was made 2.5 cm proximal to the radial styloid. Three pin sizes and four pin configurations were used to fix the fracture, and the constructs were mechanically tested. Results show that at least a .062-inch pin was required for any significant changes in rigidity of the four pin configurations tested to be discerned. Cross-pinning with two radial styloid pins and placement of a pin from the ulnar corner of the radius as the most rigid construct in both torsion and cantilever bending.
引用
收藏
页码:252 / 257
页数:6
相关论文
共 8 条
[2]  
COLLICUT J, 1994, J BONE JOINT SU B S1, V76, P23
[4]   SEVERE FRACTURES OF THE DISTAL RADIUS - EFFECT OF AMOUNT AND DURATION OF EXTERNAL FIXATOR DISTRACTION ON OUTCOME [J].
KAEMPFFE, FA ;
WHEELER, DR ;
PEIMER, CA ;
HVISDAK, KS ;
CERAVOLO, J ;
SENALL, J .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1993, 18A (01) :33-41
[5]   PERCUTANEOUS KIRSCHNER WIRE STABILIZATION FOLLOWING CLOSED REDUCTION OF COLLES FRACTURES [J].
MAH, ET ;
ATKINSON, RN .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1992, 17B (01) :55-62
[6]  
Rayhack J M, 1989, J Orthop Trauma, V3, P107, DOI 10.1097/00005131-198906000-00004
[7]  
RAYHACK JM, 1993, ORTHOP CLIN N AM, V24, P287
[8]  
[No title captured]