Numerical study on the operating performances of a novel frost-free air-source heat pump unit using three different types of refrigerant

被引:45
|
作者
Wang, Zhihua [1 ]
Wang, Fenghao [1 ]
Ma, Zhenjun [2 ]
Song, Mengjie [3 ,4 ]
机构
[1] Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Xian 710049, Shaanxi, Peoples R China
[2] Univ Wollongong, Fac Engn & Informat Sci, SBRC, Wollongong, NSW 2522, Australia
[3] Guangdong Univ Technol, Sch Mat & Energy, Guangdong Prov Key Lab Funct Soft Condensed Matte, Guangzhou, Guangdong, Peoples R China
[4] Hong Kong Univ Sci & Technol, Dept Mech & Aerosp Engn, Hong Kong, Hong Kong, Peoples R China
基金
中国博士后科学基金;
关键词
Numerical study; Air-source heat pump; Frost-free; R134a; R22 and R407C; Dehumidification; HOT-GAS BYPASS; WATER-HEATER; DEFROSTING PERFORMANCE; MELTED FROST; OUTDOOR COIL; R22; R407C; SIMULATION; R134A; ALTERNATIVES;
D O I
10.1016/j.applthermaleng.2016.10.040
中图分类号
O414.1 [热力学];
学科分类号
摘要
Air-source heat pump (ASHP) is a promising device using in residential buildings because of its energy savings. Besides, R134a and R407C as environmental friendly refrigerant have advantage to apply into heat pump system. In this study, an investigation of a novel frost-free ASHP system, integrated with dehumidification and thermal energy storage, working with R134a and R407C as an R22 alternative, was presented. A mathematical model of the system is constructed and verified by comparison with experimental data that shows the measured results are in good accordance with the numerical ones. According to the mathematical model, the dynamic performance of the system is characterized by dehumidification and regeneration efficiency, suction and discharge pressure, COP and so on at ambient temperature of 0 degrees C and RH (relatively humidity) of 85%. The results show that the time for keeping the evaporator frost-free operation for R22, R407C and R134a are 29, 34 and 35 minutes, respectively. In addition, at the end of working time, the discharge pressure of compressor for R134a is 29 and 32% lower than that for R22 and R407C. What is more, at the given ambient temperature of -10 degrees C and RH of 85%, the average COP for R134a is 3.3 and 8.6%, respectively, which is higher than that for R22 and R407C. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:248 / 258
页数:11
相关论文
共 50 条
  • [1] Analysis on performance of a novel frost-free air-source heat pump system
    Li Yongcun
    Chen Guangming
    Tang Liming
    Liu Lihua
    BUILDING AND ENVIRONMENT, 2011, 46 (10) : 2052 - 2059
  • [2] Experimental analysis on a novel frost-free air-source heat pump water heater system
    Wang, Zhihua
    Zheng, Yuxin
    Wang, Fenghao
    Wang, Xinke
    Lin, Zhang
    Li, Jingchao
    Huan, Chao
    APPLIED THERMAL ENGINEERING, 2014, 70 (01) : 808 - 816
  • [3] Experimental research on a novel frost-free air source heat pump system
    Qiu J.
    Zhang X.
    Li W.
    Huagong Xuebao/CIESC Journal, 2019, 70 (04): : 1605 - 1613
  • [4] Performance evaluation of a novel frost-free air-source heat pump integrated with phase change materials (PCMs) and dehumidification
    Wang, Zhihua
    Wang, Fenghao
    Ma, Zhenjun
    Li, Chun
    Xu, Yibo
    IMPROVING RESIDENTIAL ENERGY EFFICIENCY INTERNATIONAL CONFERENCE, IREE 2017, 2017, 121 : 134 - 141
  • [5] Performance investigation of a novel frost-free air-source heat pump water heater combined with energy storage and dehumidification
    Wang, Fenghao
    Wang, Zhihua
    Zheng, Yuxin
    Lin, Zhang
    Hao, Pengfei
    Huan, Chao
    Wang, Tian
    APPLIED ENERGY, 2015, 139 : 212 - 219
  • [6] Performance analysis and comparison of five solution regeneration methods for frost-free air-source heat pump
    Zhu, Liutao
    Wang, Libo
    Ling, Yunzhi
    Gao, Enyuan
    Ma, Yuxin
    Qu, Hongshuo
    Chen, Meng
    Zhang, Xiaosong
    Huang, Shifang
    JOURNAL OF BUILDING ENGINEERING, 2025, 99
  • [7] Research progress on frost-free air source heat pump technology
    Zhang Y.
    Zhang G.
    Leng X.
    Qu X.
    Tian M.
    Huagong Xuebao/CIESC Journal, 2020, 71 (12): : 5400 - 5419
  • [8] Energetic, economic and environmental analyses of frost-free air-source heat pump in multi-type buildings and different locations
    Huang, Shifang
    Wang, Libo
    Xie, Lingyun
    Liu, Jian
    Zhang, Xiaosong
    JOURNAL OF BUILDING ENGINEERING, 2023, 80
  • [9] Exergy analysis of a frost-free air source heat pump system
    Wang, Zhihua
    Wang, Fenghao
    Gao, Xiuzhi
    Li, Ke
    Lou, Yechun
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2019, 33 (05) : 2439 - 2450
  • [10] Exergy analysis of a frost-free air source heat pump system
    Zhihua Wang
    Fenghao Wang
    Xiuzhi Gao
    Ke Li
    Yechun Lou
    Journal of Mechanical Science and Technology, 2019, 33 : 2439 - 2450