Prussian blue-modified nanoporous gold film electrode for amperometric determination of hydrogen peroxide

被引:44
作者
Ghaderi, Seyran [1 ]
Mehrgardi, Masoud Ayatollahi [1 ]
机构
[1] Univ Isfahan, Dept Chem, Esfahan 8174673441, Iran
关键词
Nanoporous gold film; Prussian blue; Hydrogen peroxide; Amperometric sensor; Electrocatalysis; SPECTROPHOTOMETRIC DETERMINATION; ELECTROCATALYTIC REDUCTION; ELECTROCHEMICAL SENSOR; SURFACE-AREA; NANOPARTICLES; BIOSENSOR; FABRICATION; GLUCOSE; H2O2; IMMOBILIZATION;
D O I
10.1016/j.bioelechem.2014.03.007
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In this manuscript, the electrocatalytic reduction of hydrogen peroxides on Prussian blue (PB) modified nanoporous gold film (NPGF) electrode is described. The PB/NPGF is prepared by simple anodizing of a smooth gold film followed by PB film electrodeposition method. The morphology of the PB/NPGF electrode is characterized using scanning electron microscopy (SEM). The effect of solution pH and the scan rates on the voltammetric responses of hydrogen peroxide have also been examined. The amperometric determination of H2O2 shows two linear dynamic responses over the concentration range of 1 mu M-10 mu M and 10 mu M-100 mu M with a detection limit of 3.6 x 10(-7) M. Furthermore, this electrode demonstrated good stability, repeatability and selectivity remarkably. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:64 / 69
页数:6
相关论文
共 50 条
[11]   Gold nanowire assembling architecture for H2O2 electrochemical sensor [J].
Guo, Shaojun ;
Wen, Dan ;
Dong, Shaojun ;
Wang, Erkang .
TALANTA, 2009, 77 (04) :1510-1517
[12]   Prussian blue @ platinum nanoparticles/graphite felt nanocomposite electrodes: Application as hydrogen peroxide sensor [J].
Han, Lijuan ;
Tricard, Simon ;
Fang, Jian ;
Zhao, Jihua ;
Shen, Weiguo .
BIOSENSORS & BIOELECTRONICS, 2013, 43 :120-124
[13]   Selective permeation of hydrogen peroxide through polyelectrolyte multilayer films and its use for amperometric biosensors [J].
Hoshi, T ;
Saiki, H ;
Kuwazawa, S ;
Tsuchiya, C ;
Chen, Q ;
Anzai, J .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5310-5315
[14]   ACCURACY OF DETERMINATION OF HYDROGEN PEROXIDE BY CERATE OXIDIMETRY [J].
HURDIS, EC ;
ROMEYN, H .
ANALYTICAL CHEMISTRY, 1954, 26 (02) :320-325
[15]   ELECTROCHEMISTRY OF POLYNUCLEAR TRANSITION-METAL CYANIDES - PRUSSIAN BLUE AND ITS ANALOGS [J].
ITAYA, K ;
UCHIDA, I ;
NEFF, VD .
ACCOUNTS OF CHEMICAL RESEARCH, 1986, 19 (06) :162-168
[16]   Nanoporous metal (Cu, Ag, Au) films with high surface area: General fabrication and preliminary electrochemical performance [J].
Jia, Falong ;
Yu, Chuanfang ;
Deng, Kejian ;
Zhang, Lizhi .
JOURNAL OF PHYSICAL CHEMISTRY C, 2007, 111 (24) :8424-8431
[17]   Fabrication of nanoporous gold film electrodes with ultrahigh surface area and electrochemical activity [J].
Jia, Falong ;
Yu, Chuanfang ;
Ai, Zhihui ;
Zhang, Lizhi .
CHEMISTRY OF MATERIALS, 2007, 19 (15) :3648-3653
[18]   A PHOTORESPONSIVE GRAPHITE ELECTRODE COATED WITH PRUSSIAN BLUE [J].
KANEKO, M ;
HARA, S ;
YAMADA, A .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 194 (01) :165-168
[19]   The electrocatalytic activity of Prussian blue in hydrogen peroxide reduction studied using a wall-jet electrode with continuous flow [J].
Karyakin, AA ;
Karyakina, EE ;
Gorton, L .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 456 (1-2) :97-104
[20]   A HIGH-SENSITIVE GLUCOSE AMPEROMETRIC BIOSENSOR BASED ON PRUSSIAN-BLUE MODIFIED ELECTRODES [J].
KARYAKIN, AA ;
GITELMACHER, OV ;
KARYAKINA, EE .
ANALYTICAL LETTERS, 1994, 27 (15) :2861-2869