Electrochemical detection of tricyclic antidepressant drugs by HPLC using highly boron-doped diamond electrodes

被引:123
作者
Ivandini, TA
Sarada, BV
Terashima, C
Rao, TN
Tryk, DA
Ishiguro, H
Kubota, Y
Fujishima, A
机构
[1] Univ Tokyo, Sch Engn, Dept Appl Chem, Bunkyo Ku, Tokyo 1138656, Japan
[2] Yokohama City Univ, Sch Med, Dept Urol, Kanazawa Ku, Yokohama, Kanagawa 2368567, Japan
基金
日本学术振兴会;
关键词
tricyclic antidepressant drugs; boron-doped diamond; HPLC; plasma sample; reproducibility;
D O I
10.1016/S0022-0728(02)00666-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Boron-doped diamond (BDD) electrodes have been examined for the electrochemical detection of six tricyclic antidepressant drugs (TCAs): iniipramine, desipramine, clomipramine, amitriptyline, nortriptyline, and doxepin. Cyclic voltammetry, flow injection analysis (FIA) and HPLC with electrochemical detection have been used to study the oxidation reactions and to detect the TCAs. At diamond electrodes, well-defined and highly reproducible voltammograms were obtained for all six drugs with a signal to background (S/B) ratio about 2-4 times greater than those at glassy carbon electrodes. Diamond is the first electrode material to show well-defined voltammograms for nortriptyline due to its wide potential window. In the FIA-mode, at an operation potential of 0.85 V versus Ag \ AgCl, diamond exhibited a background current of 7 nA with rapid stabilization (15 min) conversely to the case of GC, which appeared to stabilize after I h, but again increased thereafter. The analytical peaks of HPLC for the TCAs were well resolved. Linear calibration curves were linear over the ranges from 0.05 to 100 muM. The limits of detection (S/N = 3) were 3 nM for iniipramine and desipramine, 0.5 nM for clomiprarnine, 163 nM amitriptyline, 1080 nM for nortriptyline and 92 nM for doxepin. The electrodes have shown reproducible results over several days of analysis. This method has been applied for the determination of imipramine and desipramme in plasma samples. The BDD surface was reproducible with no adsorption of blood components during plasma analysis. This work shows the promising use of diamond as an amperometric detector in HPLC, especially for TCA analysis. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:117 / 126
页数:10
相关论文
共 36 条
  • [1] Solid-phase extraction with liquid chromatography and ultraviolet detection for the assay of antidepressant drugs in human plasma
    Bakkali, A
    Corta, E
    Ciria, JI
    Berrueta, LA
    Gallo, B
    Vicente, F
    [J]. TALANTA, 1999, 49 (04) : 773 - 783
  • [2] Voltammetric determination of imipramine hydrochloride and amitriptyline hydrochloride using a polymer-modified carbon paste electrode
    Biryol, I
    Uslu, B
    Kucukyavuz, Z
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 15 (03) : 371 - 381
  • [3] ELECTROANALYTICAL STUDY OF TRICYCLIC ANTIDEPRESSANTS
    BISHOP, E
    HUSSEIN, W
    [J]. ANALYST, 1984, 109 (01) : 73 - 80
  • [4] Simultaneous determination of imipramine, desipramine and their 2- and 10-hydroxylated metabolites in human plasma and urine by high-performance liquid chromatography
    Chen, AG
    Wing, YK
    Chiu, H
    Lee, S
    Chen, CN
    Chan, K
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1997, 693 (01): : 153 - 158
  • [5] VACUUM HEAT-TREATMENT FOR ACTIVATION OF GLASSY-CARBON ELECTRODES
    FAGAN, DT
    HU, IF
    KUWANA, T
    [J]. ANALYTICAL CHEMISTRY, 1985, 57 (14) : 2759 - 2763
  • [6] ELECTROCHEMICAL OXIDATION OF IMINOBIBENZYL AND RELATED COMPOUNDS
    FRANK, SN
    BARD, AJ
    LEDWITH, A
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1975, 122 (07) : 898 - 904
  • [7] Polycrystalline diamond electrodes: basic properties and applications as amperometric detectors in flow injection analysis and liquid chromatography
    Granger, MC
    Xu, JS
    Strojek, JW
    Swain, GM
    [J]. ANALYTICA CHIMICA ACTA, 1999, 397 (1-3) : 145 - 161
  • [8] Analysis of tricyclic antidepressants using electrogenerated chemiluminescence
    Greenway, GM
    Dolman, SJL
    [J]. ANALYST, 1999, 124 (05) : 759 - 762
  • [9] Electrochemical characterization of the nanoporous honeycomb diamond electrode as an electrical double-layer capacitor
    Honda, K
    Rao, TN
    Tryk, DA
    Fujishima, A
    Watanabe, M
    Yasui, K
    Masuda, H
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2000, 147 (02) : 659 - 664
  • [10] ACTIVATION AND DEACTIVATION OF GLASSY-CARBON ELECTRODES
    HU, IF
    KARWEIK, DH
    KUWANA, T
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 188 (1-2): : 59 - 72