Safety and efficacy of intracranial aneurysm embolization using the "combined remodeling technique": low-profile stents delivered through double lumen balloons: a multicenter experience

被引:16
作者
Martinez-Galdamez, Mario [1 ]
Orlov, Kirill [2 ]
Kadziolka, Krzysztof [3 ]
Puthuran, Mani [4 ]
Kalousek, Vladimir [5 ]
Pabon, Boris [6 ]
Escartin, Jorge [1 ]
Rodriguez, Claudio [1 ]
Chandran, Arun [4 ]
Kislitsin, Dmitry [2 ]
Berestov, Vadim [2 ]
Vega, Pedro [7 ]
Diaz, Carlos [6 ]
Dabus, Guilherme [8 ,9 ]
机构
[1] Hosp Univ Fdn Jimenez Diaz, Grp Quironsalud, Endovasc Neurosurg Intervent Neuroradiol, Madrid, Spain
[2] Natl Med Res Ctr, Meshalkin Clin, Neurosurg Dept, Endovasc Neurosurg, Novosibirsk, Russia
[3] Western Hosp, Childrens Mem Hlth Inst, Dept Neurosurg, Endovasc Neurosurg, Grodzisk Mazowiecki, Poland
[4] Walton Ctr NHS Fdn Trust, Dept Neuroradiol, Liverpool, Merseyside, England
[5] Clin Hosp Ctr Sestre Milosrdnice, Dept Radiol, Intervent Neuroradiol, Zagreb, Croatia
[6] Angioteam Angiosur, Intervent Neuroradiol, Medellin, Colombia
[7] Hosp Univ Cent Asturias, Intervent Neuroradiol Radiol Dept, Oviedo, Spain
[8] Miami Cardiac & Vasc Inst, Endovasc Neurosurg, Miami, FL USA
[9] Baptist Neurosci Ctr, Miami, FL USA
关键词
Intracranial aneurysm; Double-lumen balloon; Low-profile stent; COIL EMBOLIZATION; ASSISTED COILING; COHORT;
D O I
10.1007/s00234-019-02240-x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Since appearance of the balloon-remodeling technique and stent-assisted coiling, complex aneurysms have been treated successfully by endovascular means worldwide. Although these two techniques have been widely proven, the combination of both traditionally made the procedures more complicated technically. The aim of our study was to determine the technical success, safety, and efficacy of the low-profile stents delivered through double lumen balloons. Methods Clinical, procedural, and angiographic data were analyzed. Results Eighty-four patients (55 women; age range 20-81 years) harboring 86 aneurysms were included in this study. Aneurysm maximal diameter ranged from 2 to 26 mm, with mean 7.5 mm. There were 62 unruptured, 15 recanalized, and 9 acutely ruptured aneurysms. Aneurysm locations were ACoA (31), MCA (36), supraclinoid ICA (4), carotid bifurcation (2), basilar (7), PCA (3), PICA (2), and VA (1). Ninety-three devices were implanted (63 LVIS jr, 15 LEO Baby, 14 ACCLINO Flex and 1 Neuroform Atlas) through the double lumen balloons (Scepter C or XC and Eclipse 2 L). We found 2 minor clinical events (2.4%) and 1 major event (1.2%). Total intra-procedural technical complication rate was 11.6%. Follow-up was available for 71 patients with an average follow-up of 7 months. Complete and near complete occlusion was 90.1%. Residual aneurysms were seen in 9.9%. Conclusion The "combined remodeling technique" with low-profile stents delivered through double-lumen balloons is technically feasible, safe, and effective for the treatment of intracranial aneurysms. This technique allows the operator to avoid extra maneuvers.
引用
收藏
页码:1067 / 1072
页数:6
相关论文
共 22 条
[11]  
Moret J, 1997, Interv Neuroradiol, V3, P21
[12]  
Park SY, 2017, INTERV NEUROL, V6, P170, DOI 10.1159/000471890
[13]   Remodeling Technique for Endovascular Treatment of Ruptured Intracranial Aneurysms Had a Higher Rate of Adequate Postoperative Occlusion than Did Conventional Coil Embolization with Comparable Safety [J].
Pierot, Laurent ;
Cognard, Christophe ;
Anxionnat, Rene ;
Ricolfi, Frederic .
RADIOLOGY, 2011, 258 (02) :546-553
[14]   Balloons and stents in the endovascular treatment of cerebral aneurysms: vascular anatomy remodeled [J].
Piotin, Michel ;
Blanc, Raphael .
FRONTIERS IN NEUROLOGY, 2014, 5
[15]   Stent-Assisted Coiling of Intracranial Aneurysms Clinical and Angiographic Results in 216 Consecutive Aneurysms [J].
Piotin, Michel ;
Blanc, Raphael ;
Spelle, Laurent ;
Mounayer, Charbel ;
Piantino, Rhelen ;
Schmidt, Paul J. ;
Moret, Jacques .
STROKE, 2010, 41 (01) :110-115
[16]  
Shankar JJS, 2016, J NEUROINTERV SURG, P1
[17]   Safety and Efficacy of Adjunctive Balloon Remodeling during Endovascular Treatment of Intracranial Aneurysms: A Literature Review [J].
Shapiro, M. ;
Babb, J. ;
Becske, T. ;
Nelson, P. K. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (09) :1777-1781
[18]   Combined balloon stent technique with the Scepter C balloon and low-profile visualized intraluminal stent for the treatment of intracranial aneurysms [J].
Spiotta, Alejandro M. ;
Miranpuri, Amrendra ;
Chaudry, M. Imran ;
Turner, Raymond D. ;
Turk, Aquilla S. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2013, 5 :III79-III82
[19]   Recanalization Rates after Endovascular Coil Embolization in a Cohort of Matched Ruptured and Unruptured Cerebral Aneurysms [J].
Tan, I. Y. L. ;
Agid, R. F. ;
Willinsky, R. A. .
INTERVENTIONAL NEURORADIOLOGY, 2011, 17 (01) :27-35
[20]   Stent-assisted coil embolization of challenging intracranial aneurysms: initial and mid-term results with low-profile ACCLINO devices [J].
Tureli, Derya ;
Sabet, Soheil ;
Senol, Serkan ;
Andac, Nurten ;
Donmez, Halil ;
Geyik, Serdar ;
Baltacioglu, Feyyaz ;
Cekirge, Saruhan .
ACTA NEUROCHIRURGICA, 2016, 158 (08) :1545-1553