Optimisation of a headspace-solid-phase micro-extraction method for simultaneous determination of organometallic compounds of mercury, lead and tin in water by gas chromatography-tandem mass spectrometry

被引:52
|
作者
Beceiro-Gonzalez, E. [1 ]
Guimaraes, A. [2 ]
Alpendurada, M. F. [2 ,3 ]
机构
[1] Univ A Coruna, Dept Analyt Chem, La Coruna 15071, Spain
[2] IAREN Water Inst No Reg, P-4450113 Matosinhos, Portugal
[3] Univ Porto, Fac Pharm, Hydrol Lab, P-4050047 Oporto, Portugal
关键词
Speciation analysis; Solid-phase micro-extraction; Water analysis; GC-MS/MS; Lead; Mercury; Tin; ATOMIC-EMISSION-SPECTROMETRY; MULTIELEMENTAL SPECIATION ANALYSIS; IN-SITU DERIVATIZATION; ORGANOTIN COMPOUNDS; BUTYLTIN COMPOUNDS; METHYLMERCURY DETERMINATION; FLUORESCENCE SPECTROMETRY; SODIUM TETRAETHYLBORATE; ISOTOPE-DILUTION; AQUEOUS SAMPLES;
D O I
10.1016/j.chroma.2009.05.056
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, a headspace-solid-phase micro-extraction (HS-SPME) combined with gas chromatography-mass spectrometry(GC-MS) method for multielemental speciation of organometallic compounds of mercury, lead and tin in water samples was upgraded by the introduction of tandem mass spectrometry (MS/MS) as detection technique. The analytical method is based on the ethylation with NaBEt4 and simultaneous headspace-solid-phase micro-extraction of the derivative compounds followed by GC-MS/MS analysis. The main experimental parameters influencing the extraction efficiency such as derivatisation time, extraction time and extraction temperature were optimized. The overall optimum extraction conditions were the following: a 50 mu m/30 mu m divinyl-benzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) SPME fibre. 150 min derivatisation time, 15 min extraction time, sample agitation at 250 rpm and 40 degrees C extraction temperature. The analytical characteristics of the HS-SPME method combined with CC-MS and GC-MS/MS were evaluated. The combination of both techniques HS-SPME and GC-MS/MS allowed to attain lower limits of detection (4-33 ng l(-1)) than those obtained by HS-SPME-GC-MS (17-45 ng l(-1)). The proposed method presented good linear regression coefficients (r(2) > 0.9970) and repeatability (4.8-21.0%) for all the compounds under study. The accuracy of the method measured as the average percentage recovery of the compounds in spiked river water and seawater samples was higher than 80% for all the compounds Studied, except for monobutyltin in the river water sample. A Study Of the uncertainty associated with the analytical results was also carried out. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:5563 / 5569
页数:7
相关论文
共 50 条
  • [41] Simultaneous determination of polycyclic musks in blood and urine by solid supported liquid-liquid extraction and gas chromatography-tandem mass spectrometry
    Liu, Hongtao
    Huang, Liping
    Chen, Yuxin
    Guo, Liman
    Li, Limin
    Zhou, Haiyun
    Luan, Tiangang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 992 : 96 - 102
  • [42] Fast analysis of volatile compounds in essences by headspace-solid phase micro-extraction-gas chromatography-mass spectrometry
    Wang, HY
    Guo, YL
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (02) : 245 - 247
  • [43] Contribution to the determination of tributyltin in water by stir bar sorptive extraction-thermal desorption-gas chromatography-tandem mass spectrometry
    Tolgyessy, Peter
    Nagyova, Slavka
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1678
  • [44] Determination of chlorobenzenes in water by solid-phase extraction and gas chromatography mass spectrometry
    Wang, Y
    Lee, HK
    JOURNAL OF CHROMATOGRAPHY A, 1998, 803 (1-2) : 219 - 225
  • [45] Determination of ten photoinitiators in fruit juices and tea beverages by solid-phase micro-extraction coupled with gas chromatography / mass spectrometry
    Liu Pengyan
    Chen Yanjie
    Zhao Chunxia
    Tian Lei
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (12) : 1232 - 1239
  • [46] A simultaneous multiresidue analysis for 203 pesticides in soybean using florisil solid-phase extraction and gas chromatography-tandem mass spectrometry
    Shin, Yongho
    Lee, Jonghwa
    Kim, Jeong-Han
    APPLIED BIOLOGICAL CHEMISTRY, 2018, 61 (05) : 543 - 548
  • [47] Analysis of steroids in environmental water samples using solid-phase extraction and ion-trap gas chromatography-mass spectrometry and gas chromatography-tandem mass spectrometry
    Kelly, C
    JOURNAL OF CHROMATOGRAPHY A, 2000, 872 (1-2) : 309 - 314
  • [48] Study on determination trace amounts of bis(diphenylarsine) oxide in water by solid phase micro-extraction gas chromatography-mass spectrometry with selective ion monitor
    Zhou, LM
    Ma, LZ
    Nie, ZY
    Chen, J
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL V, PTS A AND B, 2005, 5 : 2139 - 2142
  • [49] Applicability of solid-phase microextraction followed by on-fiber silylation for the determination of estrogens in water samples by gas chromatography-tandem mass spectrometry
    Carpinteiro, J
    Quintana, JB
    Rodríguez, I
    Carro, AM
    Lorenzo, RA
    Cela, R
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1056 (1-2) : 179 - 185
  • [50] Simultaneous determination of endocrine disrupting phenolic compounds and steroids in water by solid-phase extraction-gas chromatography-mass spectrometry
    Liu, R
    Zhou, JL
    Wilding, A
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1022 (1-2) : 179 - 189