Determining the long-term effects of H2S concentration, relative humidity and air temperature on concrete sewer corrosion

被引:129
作者
Jiang, Guangming [1 ]
Keller, Jurg [1 ]
Bond, Philip L. [1 ]
机构
[1] Univ Queensland, Adv Water Management Ctr, St Lucia, Qld 4072, Australia
基金
澳大利亚研究理事会;
关键词
Sewer; Corrosion; Concrete; Hydrogen sulfide; Humidity; Temperature; BIOGENIC SULFURIC-ACID; SULFIDE-INDUCED CORROSION; WASTE-WATER; CORRODING CONCRETE; CEMENTITIOUS MATERIALS; OXIDATION; PH; BIODETERIORATION; THIOBACILLUS; KINETICS;
D O I
10.1016/j.watres.2014.07.026
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Many studies of sewer corrosion are performed in accelerated conditions that are not representing the actual corrosion processes. This study investigated the effects of various factors over 3.5 years under controlled conditions simulating the sewer environment. Concrete coupons prepared from precorroded sewers were exposed, both in the gas phase and partially submerged in wastewater, in laboratory controlled corrosion chambers. Over the 45 month exposure period, three environmental factors of H2S concentration, relative humidity and air temperature were controlled at different levels in the corrosion chambers. A total of 36 exposure conditions were investigated to determine the long term effects of these factors by regular retrieval of concrete coupons for detailed analysis of surface pH, corrosion layer sulfate levels and concrete loss. Corrosion rates were also determined for different exposure periods. It was found that the corrosion rate of both gas-phase and partially-submerged coupons was positively correlated with the H2S concentration in the gas phase. Relative humidity played also a role for the corrosion activity of the gas-phase coupons. However, the partially-submerged coupons were not affected by humidity as the surfaces of these coupons were saturated due to capillary suction of sewage on the coupon surface. The effect of temperature on corrosion activity varied and possibly the acclimation of corrosion-inducing microbes to temperature mitigated effects of that factor. It was apparent that biological sulfide oxidation was not the limiting step of the overall corrosion process. These findings provide real insights into the long-term effects of these key environmental factors on the sewer corrosion processes. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:157 / 169
页数:13
相关论文
共 51 条
[11]   Beneficial impact of coatings on biological generation of sulfide in concrete sewer pipes [J].
Hewayde, Esam H. ;
Nakhla, George F. ;
Allouche, Erez N. ;
Mohan, Prasanna K. .
STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2007, 3 (03) :267-277
[12]   MICROBIAL ECOLOGY OF CROWN CORROSION IN SEWERS [J].
ISLANDER, RL ;
DEVINNY, JS ;
MANSFELD, F ;
POSTYN, A ;
HONG, S .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1991, 117 (06) :751-770
[13]  
Ismail N., 1993, J CONSTRUCT MANAGE E, V20, P11
[14]   Modeling of Hydrogen Sulfide Oxidation in Concrete Corrosion Products from Sewer Pipes [J].
Jensen, Henriette Stokbro ;
Nielsen, Asbjorn Haaning ;
Hvitved-Jacobsen, Thorkild ;
Vollertsen, Jes .
WATER ENVIRONMENT RESEARCH, 2009, 81 (04) :365-373
[15]   The role of iron in sulfide induced corrosion of sewer concrete [J].
Jiang, Guangming ;
Wightman, Elaine ;
Donose, Bogdan C. ;
Yuan, Zhiguo ;
Bond, Philip L. ;
Keller, Jury .
WATER RESEARCH, 2014, 49 :166-174
[16]   Synergistic inactivation of anaerobic wastewater biofilm by free nitrous acid and hydrogen peroxide [J].
Jiang, Guangming ;
Yuan, Zhiguo .
JOURNAL OF HAZARDOUS MATERIALS, 2013, 250 :91-98
[17]   Effects of nitrate dosing on methanogenic activity in a sulfide-producing sewer biofilm reactor [J].
Jiang, Guangming ;
Sharma, Keshab Raj ;
Yuan, Zhiguo .
WATER RESEARCH, 2013, 47 (05) :1783-1792
[18]   Optimization of intermittent, simultaneous dosage of nitrite and hydrochloric acid to control sulfide and methane productions in sewers [J].
Jiang, Guangming ;
Gutierrez, Oriol ;
Sharma, Keshab Raj ;
Keller, Jurg ;
Yuan, Zhiguo .
WATER RESEARCH, 2011, 45 (18) :6163-6172
[19]  
Joseph A.P., 2010, 6 IWA SPEC C SEW PRO
[20]   Surface neutralization and H2S oxidation at early stages of sewer corrosion: Influence of temperature, relative humidity and H2S concentration [J].
Joseph, Antony P. ;
Keller, Juerg ;
Bustamante, Heriberto ;
Bond, Philip L. .
WATER RESEARCH, 2012, 46 (13) :4235-4245