Effect of a broad-spectrum LED curing light on the Knoop microhardness of four posterior resin based composites at 2, 4 and 6-mm depths

被引:23
作者
ALShaafi, Maan M. [1 ]
Haenel, Thomas [2 ,3 ,4 ]
Sullivan, Braden [2 ]
Labrie, Daniel [5 ]
Alqahtani, Mohammed Q. [1 ]
Price, Richard B. [2 ]
机构
[1] King Saud Univ, Restorat Dent Sci, POB 60169, Riyadh 11545, Saudi Arabia
[2] Dalhousie Univ, Dent Clin Sci, POB 15000, Halifax, NS B3H 4R2, Canada
[3] Univ Bonn Rhein Sieg, Appl Sci, Dept Nat Sci, Von Liebig Str 20, D-53359 Rhinebach, Germany
[4] Tomas Bata Univ Zlin, Fac Technol, Namesti TG Masaryka 275, Zlin 76272, Czech Republic
[5] Dalhousie Univ, Dept Phys & Atmospher Sci, POB 15000, Halifax, NS B3H 4R2, Canada
关键词
Bulk fill resin based composites; Broad spectrum LED curing light; Knoop microhardness; Depth of cure; BULK-FILL RESIN; MECHANICAL-PROPERTIES; POLYMERIZATION SHRINKAGE; MARTENS HARDNESS; RADIANT EXPOSURE; CURE; CONVERSION; RESTORATIONS; TEMPERATURE; KINETICS;
D O I
10.1016/j.jdent.2015.11.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To measure the Knoop microhardness at the bottom of four posterior resin-based composites (RBCs): Tetric EvoCeram Bulk Fill (Ivoclar Vivadent), SureFil SDR flow (DENTSPLY), SonicFill (Kerr), and xtra fil (Voco). Methods: The RBCs were expressed into metal rings that were 2, 4, or 6-mm thick with a 4-mm internal diameter at 30 degrees C. The uncured specimens were covered by a Mylar strip and a Bluephase 20i (Ivoclar Vivadent) polywave (R) LED light-curing unit was used in high power setting for 20 s. The specimens were then removed and placed immediately on a Knoop microhardness-testing device and the microhardness was measured at 9 points across top and bottom surfaces of each specimen. Five specimens were made for each condition. Results: As expected, for each RBC there was no significant difference in the microhardness values at the top of the 2, 4 and 6-mm thick specimens. SureFil SDR Flow was the softest resin, but was the only resin that had no significant difference between the KHN values at the bottom of the 2 and 4-mm (Mixed Model ANOVA p < 0.05). Although the KHN of SureFil SDR Flow was only marginally significantly different between the 2 and 6-mm thickness, the bottom at 6-mm was only 59% of the hardness measured at the top. Clinical significance: This study highlights that clinicians need to consider how the depth of cure was evaluated when determining the depth of cure. SureFil SDR Flow was the softest material and, in accordance with manufacturer's instructions, this RBC should be overlaid with a conventional resin. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:14 / 18
页数:5
相关论文
共 53 条
  • [1] Cuspal movement and microleakage in premolar teeth restored with a packable composite cured in bulk or in increments
    Abbas, G
    Fleming, GJP
    Harrington, E
    Shortall, ACC
    Burke, FJT
    [J]. JOURNAL OF DENTISTRY, 2003, 31 (06) : 437 - 444
  • [2] Property evolution during vitrification of dimethacrylate photopolymer networks
    Abu-elenain, Dalia A.
    Lewis, Steven H.
    Stansbury, Jeffrey W.
    [J]. DENTAL MATERIALS, 2013, 29 (11) : 1173 - 1181
  • [3] Post-cure depth of cure of bulk fill dental resin-composites
    Alrahlah, A.
    Silikas, N.
    Watts, D. C.
    [J]. DENTAL MATERIALS, 2014, 30 (02) : 149 - 154
  • [4] [Anonymous], 2014, XTRAFIL INSTR US
  • [5] [Anonymous], 2011, SON FILL DIR US
  • [6] Anusavice K.J., 2013, PHILLIPS SCIENCE OF
  • [7] Light transmittance characteristics of light-cured composite resins
    Arikawa, H
    Fujii, K
    Kanie, T
    Inoue, K
    [J]. DENTAL MATERIALS, 1998, 14 (06) : 405 - 411
  • [8] Polymer structure of a light-cured resin composite in relation to distance from the surface
    Asmussen, E
    Peutzfeldt, A
    [J]. EUROPEAN JOURNAL OF ORAL SCIENCES, 2003, 111 (03) : 277 - 279
  • [9] Burtscher P, 2013, 19 IV VIV
  • [10] In vitro comparison of mechanical properties and degree of cure of bulk fill composites
    Czasch, Pascal
    Ilie, Nicoleta
    [J]. CLINICAL ORAL INVESTIGATIONS, 2013, 17 (01) : 227 - 235